Placement of Harmonic Filter and Detuned Reactor to Improve Power Quality in Renewable Energy Ring Topology Distribution Network

Utilization of potential renewable energy sources is maximized to produce electrical power. The goal is to increase the supply of electrical power for the load without having to add new fossil fuel power plants, and to maintain energy security. Renewable energy types such as photovoltaic and wind po...

Full description

Bibliographic Details
Published in:2022 FORTEI-International Conference on Electrical Engineering, FORTEI-ICEE 2022 - Proceeding
Main Author: Gumilar L.; Afandi A.N.; Cahyani D.E.; Bin Abd Samat A.A.; Prasetyo M.W.; Melinia H.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2022
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145438732&doi=10.1109%2fFORTEI-ICEE57243.2022.9972916&partnerID=40&md5=a1741ef186b81ed9d107648ad3fda6aa
id 2-s2.0-85145438732
spelling 2-s2.0-85145438732
Gumilar L.; Afandi A.N.; Cahyani D.E.; Bin Abd Samat A.A.; Prasetyo M.W.; Melinia H.
Placement of Harmonic Filter and Detuned Reactor to Improve Power Quality in Renewable Energy Ring Topology Distribution Network
2022
2022 FORTEI-International Conference on Electrical Engineering, FORTEI-ICEE 2022 - Proceeding


10.1109/FORTEI-ICEE57243.2022.9972916
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145438732&doi=10.1109%2fFORTEI-ICEE57243.2022.9972916&partnerID=40&md5=a1741ef186b81ed9d107648ad3fda6aa
Utilization of potential renewable energy sources is maximized to produce electrical power. The goal is to increase the supply of electrical power for the load without having to add new fossil fuel power plants, and to maintain energy security. Renewable energy types such as photovoltaic and wind power plants are often used for distributed generation. The placement of renewable energy has been tried in several distribution network topologies. The integration of renewable energy in large quantities with the distribution network can cause a decrease in power quality. This paper aims to improve power quality in distribution networks that have a ring topology and lots of renewable energy. Improved power quality using harmonic filters and detuned reactors. Several conditions were made to obtain the results of the impact comparison using a harmonic filter and a detuned reactor. Condition 1, simulation of harmonics on a ring topology distribution network that is integrated with a lot of renewable energy. Condition 2, the distribution network is installed with a harmonic filter to reduce harmonic distortion from the previous scenario. Condition 3, the harmonic filter is combined with a detuned reactor in the distribution network to reduce harmonic distortion. In condition 1 the value of harmonic distortion is high. The THD-I value is 15.52% and the THD-V value is 7.07%. After comparing all the results of harmonic distortion in each condition, condition 3 gives the smallest harmonic distortion compared to other conditions. In condition 3, the THD-I value is 2.83% and the THD-V value is 2.01%. © 2022 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Gumilar L.; Afandi A.N.; Cahyani D.E.; Bin Abd Samat A.A.; Prasetyo M.W.; Melinia H.
spellingShingle Gumilar L.; Afandi A.N.; Cahyani D.E.; Bin Abd Samat A.A.; Prasetyo M.W.; Melinia H.
Placement of Harmonic Filter and Detuned Reactor to Improve Power Quality in Renewable Energy Ring Topology Distribution Network
author_facet Gumilar L.; Afandi A.N.; Cahyani D.E.; Bin Abd Samat A.A.; Prasetyo M.W.; Melinia H.
author_sort Gumilar L.; Afandi A.N.; Cahyani D.E.; Bin Abd Samat A.A.; Prasetyo M.W.; Melinia H.
title Placement of Harmonic Filter and Detuned Reactor to Improve Power Quality in Renewable Energy Ring Topology Distribution Network
title_short Placement of Harmonic Filter and Detuned Reactor to Improve Power Quality in Renewable Energy Ring Topology Distribution Network
title_full Placement of Harmonic Filter and Detuned Reactor to Improve Power Quality in Renewable Energy Ring Topology Distribution Network
title_fullStr Placement of Harmonic Filter and Detuned Reactor to Improve Power Quality in Renewable Energy Ring Topology Distribution Network
title_full_unstemmed Placement of Harmonic Filter and Detuned Reactor to Improve Power Quality in Renewable Energy Ring Topology Distribution Network
title_sort Placement of Harmonic Filter and Detuned Reactor to Improve Power Quality in Renewable Energy Ring Topology Distribution Network
publishDate 2022
container_title 2022 FORTEI-International Conference on Electrical Engineering, FORTEI-ICEE 2022 - Proceeding
container_volume
container_issue
doi_str_mv 10.1109/FORTEI-ICEE57243.2022.9972916
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145438732&doi=10.1109%2fFORTEI-ICEE57243.2022.9972916&partnerID=40&md5=a1741ef186b81ed9d107648ad3fda6aa
description Utilization of potential renewable energy sources is maximized to produce electrical power. The goal is to increase the supply of electrical power for the load without having to add new fossil fuel power plants, and to maintain energy security. Renewable energy types such as photovoltaic and wind power plants are often used for distributed generation. The placement of renewable energy has been tried in several distribution network topologies. The integration of renewable energy in large quantities with the distribution network can cause a decrease in power quality. This paper aims to improve power quality in distribution networks that have a ring topology and lots of renewable energy. Improved power quality using harmonic filters and detuned reactors. Several conditions were made to obtain the results of the impact comparison using a harmonic filter and a detuned reactor. Condition 1, simulation of harmonics on a ring topology distribution network that is integrated with a lot of renewable energy. Condition 2, the distribution network is installed with a harmonic filter to reduce harmonic distortion from the previous scenario. Condition 3, the harmonic filter is combined with a detuned reactor in the distribution network to reduce harmonic distortion. In condition 1 the value of harmonic distortion is high. The THD-I value is 15.52% and the THD-V value is 7.07%. After comparing all the results of harmonic distortion in each condition, condition 3 gives the smallest harmonic distortion compared to other conditions. In condition 3, the THD-I value is 2.83% and the THD-V value is 2.01%. © 2022 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809678025586900992