European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure
Many real-scale fire tests have been performed on timber connections to analyze the mechanical behavior of timber connections in previous years. However, little research focused on the bending performance of glued laminated (glulam) timber beam bolted connections after fire exposure. In this paper,...
Published in: | Forests |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
MDPI
2022
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85144627253&doi=10.3390%2ff13122012&partnerID=40&md5=b7aa43a929e8dc773bacf8f4457caeb3 |
id |
2-s2.0-85144627253 |
---|---|
spelling |
2-s2.0-85144627253 Shakimon M.N.; Hassan R.; Malek N.J.A.; Zainal A.; Awaludin A.; Hamid N.H.A.; Lum W.C.; Salit M.S. European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure 2022 Forests 13 12 10.3390/f13122012 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85144627253&doi=10.3390%2ff13122012&partnerID=40&md5=b7aa43a929e8dc773bacf8f4457caeb3 Many real-scale fire tests have been performed on timber connections to analyze the mechanical behavior of timber connections in previous years. However, little research focused on the bending performance of glued laminated (glulam) timber beam bolted connections after fire exposure. In this paper, the three-dimensional numerical model of the glulam timber beam bolted connections was developed and validated by experimental results. The model can simulate temperature evolution in the connections and their mechanical behavior. In the real-scale test, three (3) samples were prepared for a four-point bending test at normal temperature, while another three (3) samples were tested after exposure to a 30-min standard fire and cooled down to normal temperature. The results show the reduction of the load-carrying capacity before and after exposure to the standard fire by 23.9 kN (71.8%), 8.3 kN (26.1%), and 20.2 kN (47.6%) for bolt diameters of 12 mm, 16 mm, and 20 mm, respectively. The numerical model aims to conduct a parametric study and propose the modification of the exponential decay constant, k, for tropical glulam timber to predict the load-carrying capacity of the glulam timber beam bolted connections after exposure to standard fire. © 2022 by the authors. MDPI 19994907 English Article All Open Access; Gold Open Access |
author |
Shakimon M.N.; Hassan R.; Malek N.J.A.; Zainal A.; Awaludin A.; Hamid N.H.A.; Lum W.C.; Salit M.S. |
spellingShingle |
Shakimon M.N.; Hassan R.; Malek N.J.A.; Zainal A.; Awaludin A.; Hamid N.H.A.; Lum W.C.; Salit M.S. European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure |
author_facet |
Shakimon M.N.; Hassan R.; Malek N.J.A.; Zainal A.; Awaludin A.; Hamid N.H.A.; Lum W.C.; Salit M.S. |
author_sort |
Shakimon M.N.; Hassan R.; Malek N.J.A.; Zainal A.; Awaludin A.; Hamid N.H.A.; Lum W.C.; Salit M.S. |
title |
European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure |
title_short |
European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure |
title_full |
European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure |
title_fullStr |
European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure |
title_full_unstemmed |
European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure |
title_sort |
European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure |
publishDate |
2022 |
container_title |
Forests |
container_volume |
13 |
container_issue |
12 |
doi_str_mv |
10.3390/f13122012 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85144627253&doi=10.3390%2ff13122012&partnerID=40&md5=b7aa43a929e8dc773bacf8f4457caeb3 |
description |
Many real-scale fire tests have been performed on timber connections to analyze the mechanical behavior of timber connections in previous years. However, little research focused on the bending performance of glued laminated (glulam) timber beam bolted connections after fire exposure. In this paper, the three-dimensional numerical model of the glulam timber beam bolted connections was developed and validated by experimental results. The model can simulate temperature evolution in the connections and their mechanical behavior. In the real-scale test, three (3) samples were prepared for a four-point bending test at normal temperature, while another three (3) samples were tested after exposure to a 30-min standard fire and cooled down to normal temperature. The results show the reduction of the load-carrying capacity before and after exposure to the standard fire by 23.9 kN (71.8%), 8.3 kN (26.1%), and 20.2 kN (47.6%) for bolt diameters of 12 mm, 16 mm, and 20 mm, respectively. The numerical model aims to conduct a parametric study and propose the modification of the exponential decay constant, k, for tropical glulam timber to predict the load-carrying capacity of the glulam timber beam bolted connections after exposure to standard fire. © 2022 by the authors. |
publisher |
MDPI |
issn |
19994907 |
language |
English |
format |
Article |
accesstype |
All Open Access; Gold Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1809678157709574144 |