Use of reliability tested clinically data towards a portable device measurement kit system for upper limb spasticity

Spasticity refers to the abnormal symptom of having resistance in the joints when patients tried to make a movement. Patients with spasticity need to undergo multiple therapy sessions with medical intervention to ensure that the upper limb achieve maximal function. Modified Ashworth Scale (MAS) is f...

Full description

Bibliographic Details
Published in:Malaysian Journal of Fundamental and Applied Sciences
Main Author: Johar K.; Zakaria N.A.C.; Hanapiah F.A.; Yee L.C.; Othman N.A.; Ridhuan M.A.
Format: Article
Language:English
Published: Penerbit UTM Press 2019
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85141582705&doi=10.11113%2fmjfas.v15n4.1493&partnerID=40&md5=70039a4d0510a810c20a8f3f76c7e035
id 2-s2.0-85141582705
spelling 2-s2.0-85141582705
Johar K.; Zakaria N.A.C.; Hanapiah F.A.; Yee L.C.; Othman N.A.; Ridhuan M.A.
Use of reliability tested clinically data towards a portable device measurement kit system for upper limb spasticity
2019
Malaysian Journal of Fundamental and Applied Sciences
15
4
10.11113/mjfas.v15n4.1493
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85141582705&doi=10.11113%2fmjfas.v15n4.1493&partnerID=40&md5=70039a4d0510a810c20a8f3f76c7e035
Spasticity refers to the abnormal symptom of having resistance in the joints when patients tried to make a movement. Patients with spasticity need to undergo multiple therapy sessions with medical intervention to ensure that the upper limb achieve maximal function. Modified Ashworth Scale (MAS) is frequently used in clinical assessment with grading on a scale. However, this scale is limited in sensitivity and the accuracy of this evaluation is dependent on the physician's and therapist's experience. This study suggests developing a portable measurement device kit system during clinical assessment to reduce inter- and intra-rater variability, and to assist clinicians in making quick clinical evaluation of spasticity. In this study, 19 patients were involved in the data acquisition. Assessment data from upper limb of patients with spasticity were recorded using a Manual Muscle Tester (MMT) and digital goniometer to measure force and the angular motion. During the assessment, patients were examined through slow and fast motion for spasticity evaluation. The collected data were analyzed to study intra-rater reliability value by using Statistical Package for the Social Sciences (SPSS). The results of Intraclass Correlation Coefficient (ICC) values for all patients were in range 0.78 to 0.89. It can be considered that the collected data was reliable and can be used to formulate a model towards the development of a portable device measurement kit system for upper limb spasticity. © 2019 Penerbit UTM Press. All rights reserved.
Penerbit UTM Press
2289599X
English
Article
All Open Access; Gold Open Access
author Johar K.; Zakaria N.A.C.; Hanapiah F.A.; Yee L.C.; Othman N.A.; Ridhuan M.A.
spellingShingle Johar K.; Zakaria N.A.C.; Hanapiah F.A.; Yee L.C.; Othman N.A.; Ridhuan M.A.
Use of reliability tested clinically data towards a portable device measurement kit system for upper limb spasticity
author_facet Johar K.; Zakaria N.A.C.; Hanapiah F.A.; Yee L.C.; Othman N.A.; Ridhuan M.A.
author_sort Johar K.; Zakaria N.A.C.; Hanapiah F.A.; Yee L.C.; Othman N.A.; Ridhuan M.A.
title Use of reliability tested clinically data towards a portable device measurement kit system for upper limb spasticity
title_short Use of reliability tested clinically data towards a portable device measurement kit system for upper limb spasticity
title_full Use of reliability tested clinically data towards a portable device measurement kit system for upper limb spasticity
title_fullStr Use of reliability tested clinically data towards a portable device measurement kit system for upper limb spasticity
title_full_unstemmed Use of reliability tested clinically data towards a portable device measurement kit system for upper limb spasticity
title_sort Use of reliability tested clinically data towards a portable device measurement kit system for upper limb spasticity
publishDate 2019
container_title Malaysian Journal of Fundamental and Applied Sciences
container_volume 15
container_issue 4
doi_str_mv 10.11113/mjfas.v15n4.1493
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85141582705&doi=10.11113%2fmjfas.v15n4.1493&partnerID=40&md5=70039a4d0510a810c20a8f3f76c7e035
description Spasticity refers to the abnormal symptom of having resistance in the joints when patients tried to make a movement. Patients with spasticity need to undergo multiple therapy sessions with medical intervention to ensure that the upper limb achieve maximal function. Modified Ashworth Scale (MAS) is frequently used in clinical assessment with grading on a scale. However, this scale is limited in sensitivity and the accuracy of this evaluation is dependent on the physician's and therapist's experience. This study suggests developing a portable measurement device kit system during clinical assessment to reduce inter- and intra-rater variability, and to assist clinicians in making quick clinical evaluation of spasticity. In this study, 19 patients were involved in the data acquisition. Assessment data from upper limb of patients with spasticity were recorded using a Manual Muscle Tester (MMT) and digital goniometer to measure force and the angular motion. During the assessment, patients were examined through slow and fast motion for spasticity evaluation. The collected data were analyzed to study intra-rater reliability value by using Statistical Package for the Social Sciences (SPSS). The results of Intraclass Correlation Coefficient (ICC) values for all patients were in range 0.78 to 0.89. It can be considered that the collected data was reliable and can be used to formulate a model towards the development of a portable device measurement kit system for upper limb spasticity. © 2019 Penerbit UTM Press. All rights reserved.
publisher Penerbit UTM Press
issn 2289599X
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1820775467036180480