Optimum energy management strategy with enhanced time of use tariff for campus building using particle swarm optimization

Enhanced time of use (ETOU) tariff was introduced by Tenaga Nasional Berhad (TNB) in 2016 to promote demand response for commercial and industrial consumers. The ETOU tariff scheme offers different tariff rates at different times of the day. However, increment of electricity expenses might occur if...

Full description

Bibliographic Details
Published in:Indonesian Journal of Electrical Engineering and Computer Science
Main Author: Mahmud N.A.; Dahlan N.Y.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2022
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85139347675&doi=10.11591%2fijeecs.v28.i2.pp644-653&partnerID=40&md5=e975bf46ec778431d4395e497d2b3e0b
id 2-s2.0-85139347675
spelling 2-s2.0-85139347675
Mahmud N.A.; Dahlan N.Y.
Optimum energy management strategy with enhanced time of use tariff for campus building using particle swarm optimization
2022
Indonesian Journal of Electrical Engineering and Computer Science
28
2
10.11591/ijeecs.v28.i2.pp644-653
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85139347675&doi=10.11591%2fijeecs.v28.i2.pp644-653&partnerID=40&md5=e975bf46ec778431d4395e497d2b3e0b
Enhanced time of use (ETOU) tariff was introduced by Tenaga Nasional Berhad (TNB) in 2016 to promote demand response for commercial and industrial consumers. The ETOU tariff scheme offers different tariff rates at different times of the day. However, increment of electricity expenses might occur if consumers fail to optimally shift their consumption to lower rate hours and causing higher usage during peak hours. Furthermore, the time-based pricing tariff is still new to Malaysian consumers, thus consumers have lack of knowledge to perform demand response. Therefore, this research proposes an optimum load management strategy under the ETOU tariff for a commercial building using particle swarm optimization (PSO). The model was applied for Universiti Teknologi MARA (UiTM) Complex Engineering Shah Alam. Load profile of five different buildings in the complex were used as inputs for the study. The analyses were carried out at different controlled loads weightage factors ranged from 10-40% for load shifting strategy to determine the optimal solution. Results show the electricity cost decreases in all the controlled load weightage factors tested on the buildings after applying the load management strategy. The weightage factor of 40% provides the best solution for all buildings, saving 1-4% on the monthly bills. © 2022 Institute of Advanced Engineering and Science. All rights reserved.
Institute of Advanced Engineering and Science
25024752
English
Article
All Open Access; Gold Open Access
author Mahmud N.A.; Dahlan N.Y.
spellingShingle Mahmud N.A.; Dahlan N.Y.
Optimum energy management strategy with enhanced time of use tariff for campus building using particle swarm optimization
author_facet Mahmud N.A.; Dahlan N.Y.
author_sort Mahmud N.A.; Dahlan N.Y.
title Optimum energy management strategy with enhanced time of use tariff for campus building using particle swarm optimization
title_short Optimum energy management strategy with enhanced time of use tariff for campus building using particle swarm optimization
title_full Optimum energy management strategy with enhanced time of use tariff for campus building using particle swarm optimization
title_fullStr Optimum energy management strategy with enhanced time of use tariff for campus building using particle swarm optimization
title_full_unstemmed Optimum energy management strategy with enhanced time of use tariff for campus building using particle swarm optimization
title_sort Optimum energy management strategy with enhanced time of use tariff for campus building using particle swarm optimization
publishDate 2022
container_title Indonesian Journal of Electrical Engineering and Computer Science
container_volume 28
container_issue 2
doi_str_mv 10.11591/ijeecs.v28.i2.pp644-653
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85139347675&doi=10.11591%2fijeecs.v28.i2.pp644-653&partnerID=40&md5=e975bf46ec778431d4395e497d2b3e0b
description Enhanced time of use (ETOU) tariff was introduced by Tenaga Nasional Berhad (TNB) in 2016 to promote demand response for commercial and industrial consumers. The ETOU tariff scheme offers different tariff rates at different times of the day. However, increment of electricity expenses might occur if consumers fail to optimally shift their consumption to lower rate hours and causing higher usage during peak hours. Furthermore, the time-based pricing tariff is still new to Malaysian consumers, thus consumers have lack of knowledge to perform demand response. Therefore, this research proposes an optimum load management strategy under the ETOU tariff for a commercial building using particle swarm optimization (PSO). The model was applied for Universiti Teknologi MARA (UiTM) Complex Engineering Shah Alam. Load profile of five different buildings in the complex were used as inputs for the study. The analyses were carried out at different controlled loads weightage factors ranged from 10-40% for load shifting strategy to determine the optimal solution. Results show the electricity cost decreases in all the controlled load weightage factors tested on the buildings after applying the load management strategy. The weightage factor of 40% provides the best solution for all buildings, saving 1-4% on the monthly bills. © 2022 Institute of Advanced Engineering and Science. All rights reserved.
publisher Institute of Advanced Engineering and Science
issn 25024752
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809678158118518784