Top of Line Corrosion (TLC) Behaviour with Presence of Gas Condensate in CO2 Wet Gas Pipeline

Top of line corrosion (TLC) in CO2 wet gas pipeline is a major threat to oil and gas industry, where difference in temperature of internal pipeline and outside environment leads to condensation of water in a stratified flow regime. This condensed water is corrosive to the pipelines’ surface because...

Full description

Bibliographic Details
Published in:Lecture Notes in Mechanical Engineering
Main Author: Jufri F.S.M.; Jarni H.H.; Razlan M.R.M.; Noor A.M.; Yaakob N.
Format: Conference paper
Language:English
Published: Springer Science and Business Media Deutschland GmbH 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85134157950&doi=10.1007%2f978-981-19-1851-3_15&partnerID=40&md5=edf99626d53fde9df07ece2bad56a9c4
id 2-s2.0-85134157950
spelling 2-s2.0-85134157950
Jufri F.S.M.; Jarni H.H.; Razlan M.R.M.; Noor A.M.; Yaakob N.
Top of Line Corrosion (TLC) Behaviour with Presence of Gas Condensate in CO2 Wet Gas Pipeline
2023
Lecture Notes in Mechanical Engineering


10.1007/978-981-19-1851-3_15
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85134157950&doi=10.1007%2f978-981-19-1851-3_15&partnerID=40&md5=edf99626d53fde9df07ece2bad56a9c4
Top of line corrosion (TLC) in CO2 wet gas pipeline is a major threat to oil and gas industry, where difference in temperature of internal pipeline and outside environment leads to condensation of water in a stratified flow regime. This condensed water is corrosive to the pipelines’ surface because it contains organic acids and dissolved acidic gases such as CO2 and H2S. In oil and gas field, gas condensate is usually present in the pipeline. However, only gas condensate-free TLC systems were usually studied. This condensable hydrocarbon may affect condensation process as it is immiscible with water which leads to different wettability on the pipeline surface. In this work, TLC testing with and without gas condensate was carried out to study the effect of gas condensate on the water condensation rate (WCR) and the TLC rate. The experimental work was carried out in a 2.0 L TLC testing unit using API 5L X65 carbon steel coupons for 7 days. The corrosion rate was calculated using the weight loss method in accordance to ASTM G1-03, surface morphology analysis by Scanning Electron Microscopy (SEM) and the pitting was observed by using the Infinite Focus Microscope (IFM) in accordance to ASTM 46-94. The presence of gas condensate in the system led to a 62% lower WCR compared to that of gas condensate-free system at the same temperature difference between gas and steel (∆T, °C). TLC rate was found to be higher in gas condensate-free system with a difference of 33%. Overall, the presence of gas condensate has reduced the WCR which then reduced the TLC rate. © 2023, The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
Springer Science and Business Media Deutschland GmbH
21954356
English
Conference paper

author Jufri F.S.M.; Jarni H.H.; Razlan M.R.M.; Noor A.M.; Yaakob N.
spellingShingle Jufri F.S.M.; Jarni H.H.; Razlan M.R.M.; Noor A.M.; Yaakob N.
Top of Line Corrosion (TLC) Behaviour with Presence of Gas Condensate in CO2 Wet Gas Pipeline
author_facet Jufri F.S.M.; Jarni H.H.; Razlan M.R.M.; Noor A.M.; Yaakob N.
author_sort Jufri F.S.M.; Jarni H.H.; Razlan M.R.M.; Noor A.M.; Yaakob N.
title Top of Line Corrosion (TLC) Behaviour with Presence of Gas Condensate in CO2 Wet Gas Pipeline
title_short Top of Line Corrosion (TLC) Behaviour with Presence of Gas Condensate in CO2 Wet Gas Pipeline
title_full Top of Line Corrosion (TLC) Behaviour with Presence of Gas Condensate in CO2 Wet Gas Pipeline
title_fullStr Top of Line Corrosion (TLC) Behaviour with Presence of Gas Condensate in CO2 Wet Gas Pipeline
title_full_unstemmed Top of Line Corrosion (TLC) Behaviour with Presence of Gas Condensate in CO2 Wet Gas Pipeline
title_sort Top of Line Corrosion (TLC) Behaviour with Presence of Gas Condensate in CO2 Wet Gas Pipeline
publishDate 2023
container_title Lecture Notes in Mechanical Engineering
container_volume
container_issue
doi_str_mv 10.1007/978-981-19-1851-3_15
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85134157950&doi=10.1007%2f978-981-19-1851-3_15&partnerID=40&md5=edf99626d53fde9df07ece2bad56a9c4
description Top of line corrosion (TLC) in CO2 wet gas pipeline is a major threat to oil and gas industry, where difference in temperature of internal pipeline and outside environment leads to condensation of water in a stratified flow regime. This condensed water is corrosive to the pipelines’ surface because it contains organic acids and dissolved acidic gases such as CO2 and H2S. In oil and gas field, gas condensate is usually present in the pipeline. However, only gas condensate-free TLC systems were usually studied. This condensable hydrocarbon may affect condensation process as it is immiscible with water which leads to different wettability on the pipeline surface. In this work, TLC testing with and without gas condensate was carried out to study the effect of gas condensate on the water condensation rate (WCR) and the TLC rate. The experimental work was carried out in a 2.0 L TLC testing unit using API 5L X65 carbon steel coupons for 7 days. The corrosion rate was calculated using the weight loss method in accordance to ASTM G1-03, surface morphology analysis by Scanning Electron Microscopy (SEM) and the pitting was observed by using the Infinite Focus Microscope (IFM) in accordance to ASTM 46-94. The presence of gas condensate in the system led to a 62% lower WCR compared to that of gas condensate-free system at the same temperature difference between gas and steel (∆T, °C). TLC rate was found to be higher in gas condensate-free system with a difference of 33%. Overall, the presence of gas condensate has reduced the WCR which then reduced the TLC rate. © 2023, The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
publisher Springer Science and Business Media Deutschland GmbH
issn 21954356
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677780619624448