Preliminary Analysis of the Geomagnetically Induced Current at the Malaysian Power Network

The formation of the Geomagnetic Induced Current (GIC) from the underground becoming a threat to the electrical appliances due to its natural form of current that flows from the underground to electrical appliances. The measurement at the neutral point of the 275kV transformer has been conducted to...

Full description

Bibliographic Details
Published in:International Conference on Space Science and Communication, IconSpace
Main Author: Burhanudin K.; Jusoh M.H.; Farid Abidin A.; Hidayat M.N.; Helmy Hashim M.; Abd Latiff Z.I.; Yoshikawa A.
Format: Conference paper
Language:English
Published: IEEE Computer Society 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85130214428&doi=10.1109%2fIconSpace53224.2021.9768744&partnerID=40&md5=cd51f27da2fe77a0c6bd2dae7f423a51
id 2-s2.0-85130214428
spelling 2-s2.0-85130214428
Burhanudin K.; Jusoh M.H.; Farid Abidin A.; Hidayat M.N.; Helmy Hashim M.; Abd Latiff Z.I.; Yoshikawa A.
Preliminary Analysis of the Geomagnetically Induced Current at the Malaysian Power Network
2021
International Conference on Space Science and Communication, IconSpace
2021-November

10.1109/IconSpace53224.2021.9768744
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85130214428&doi=10.1109%2fIconSpace53224.2021.9768744&partnerID=40&md5=cd51f27da2fe77a0c6bd2dae7f423a51
The formation of the Geomagnetic Induced Current (GIC) from the underground becoming a threat to the electrical appliances due to its natural form of current that flows from the underground to electrical appliances. The measurement at the neutral point of the 275kV transformer has been conducted to identify the existence of the GIC from the underground. The measurement is conducted at the Tenaga Nasional Berhad (TNB), KUL South, Taman Pelangi, Petaling Jaya, Kuala Lumpur with geographic latitude and longitude (3° 4' 37"and 101° 39' 55") by using HIOKI measurement equipment. Based on the measurement conducted, there are two categories of the storm which existed during the measurement which is a moderate and weak storm. The preliminary analysis on the level of the GIC is conducted based on the data from OmniWeb, local magnetic data acquisition system (MAGDAS) data, and the measurement data at the neutral point of the transformer. The estimation of the GIC is calculated based on the local MAGDAS data. The preliminary examination of the GIC in the Malaysian Power Network is necessary to determine the GIC's threshold limit. In a pattern, the estimating process displays the similarities between the measured and calculated GIC. © 2021 IEEE.
IEEE Computer Society
21654301
English
Conference paper

author Burhanudin K.; Jusoh M.H.; Farid Abidin A.; Hidayat M.N.; Helmy Hashim M.; Abd Latiff Z.I.; Yoshikawa A.
spellingShingle Burhanudin K.; Jusoh M.H.; Farid Abidin A.; Hidayat M.N.; Helmy Hashim M.; Abd Latiff Z.I.; Yoshikawa A.
Preliminary Analysis of the Geomagnetically Induced Current at the Malaysian Power Network
author_facet Burhanudin K.; Jusoh M.H.; Farid Abidin A.; Hidayat M.N.; Helmy Hashim M.; Abd Latiff Z.I.; Yoshikawa A.
author_sort Burhanudin K.; Jusoh M.H.; Farid Abidin A.; Hidayat M.N.; Helmy Hashim M.; Abd Latiff Z.I.; Yoshikawa A.
title Preliminary Analysis of the Geomagnetically Induced Current at the Malaysian Power Network
title_short Preliminary Analysis of the Geomagnetically Induced Current at the Malaysian Power Network
title_full Preliminary Analysis of the Geomagnetically Induced Current at the Malaysian Power Network
title_fullStr Preliminary Analysis of the Geomagnetically Induced Current at the Malaysian Power Network
title_full_unstemmed Preliminary Analysis of the Geomagnetically Induced Current at the Malaysian Power Network
title_sort Preliminary Analysis of the Geomagnetically Induced Current at the Malaysian Power Network
publishDate 2021
container_title International Conference on Space Science and Communication, IconSpace
container_volume 2021-November
container_issue
doi_str_mv 10.1109/IconSpace53224.2021.9768744
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85130214428&doi=10.1109%2fIconSpace53224.2021.9768744&partnerID=40&md5=cd51f27da2fe77a0c6bd2dae7f423a51
description The formation of the Geomagnetic Induced Current (GIC) from the underground becoming a threat to the electrical appliances due to its natural form of current that flows from the underground to electrical appliances. The measurement at the neutral point of the 275kV transformer has been conducted to identify the existence of the GIC from the underground. The measurement is conducted at the Tenaga Nasional Berhad (TNB), KUL South, Taman Pelangi, Petaling Jaya, Kuala Lumpur with geographic latitude and longitude (3° 4' 37"and 101° 39' 55") by using HIOKI measurement equipment. Based on the measurement conducted, there are two categories of the storm which existed during the measurement which is a moderate and weak storm. The preliminary analysis on the level of the GIC is conducted based on the data from OmniWeb, local magnetic data acquisition system (MAGDAS) data, and the measurement data at the neutral point of the transformer. The estimation of the GIC is calculated based on the local MAGDAS data. The preliminary examination of the GIC in the Malaysian Power Network is necessary to determine the GIC's threshold limit. In a pattern, the estimating process displays the similarities between the measured and calculated GIC. © 2021 IEEE.
publisher IEEE Computer Society
issn 21654301
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809678027779473408