Performance evaluation on ultrafiltration as tertiary treatment for rubber glove wastewater

Ultrafiltration (UF) is a promising treatment solution used for tertiary treatment of industrial wastewater. However, membrane fouling is the major problem which limits the performance of the UF in industry. In the present study, the operational and separation performane of ultrafiltration of biolog...

Full description

Bibliographic Details
Published in:Materials Today: Proceedings
Main Author: Lim Y.P.; Jasimin A.; Ng L.Y.; Tan H.L.
Format: Article
Language:English
Published: Elsevier Ltd 2022
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85126781771&doi=10.1016%2fj.matpr.2022.02.454&partnerID=40&md5=cf62f13ca654eba4b0bac350c91bd124
id 2-s2.0-85126781771
spelling 2-s2.0-85126781771
Lim Y.P.; Jasimin A.; Ng L.Y.; Tan H.L.
Performance evaluation on ultrafiltration as tertiary treatment for rubber glove wastewater
2022
Materials Today: Proceedings
63

10.1016/j.matpr.2022.02.454
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85126781771&doi=10.1016%2fj.matpr.2022.02.454&partnerID=40&md5=cf62f13ca654eba4b0bac350c91bd124
Ultrafiltration (UF) is a promising treatment solution used for tertiary treatment of industrial wastewater. However, membrane fouling is the major problem which limits the performance of the UF in industry. In the present study, the operational and separation performane of ultrafiltration of biologically treated rubber glove wastewater were carried out using innovative developed organic metal membranes. Two types of commercial PolyCera® Titan (70 kDa) and PolyCera® Hydro (100 kDa) flat sheet UF membrane were applied for tertiary treatment of rubber glove wastewater. The physicochemical properties of influent and UF membranes were characterized before and after the treatment process. PolyCera® Titan membranes have slightly higher hydrophobicity, lower permeability and lower fouling tendency as compared to PolyCera® Hydro membrane. PolyCera® Titan gave higher COD, TSS, and color rejection, observed at 66.9%, 73.3%, and 82.4%, respectively. The permeate quality conformed with the regulatory discharge standard, except for the PolyCera® Hydro membrane in which the COD value surpassed the permissible limit. With its promising performance, PolyCera® membranes have great potential to reduce pollutant loading in the wastewater for efficient rubber glove wastewater treatment. © 2022
Elsevier Ltd
22147853
English
Article

author Lim Y.P.; Jasimin A.; Ng L.Y.; Tan H.L.
spellingShingle Lim Y.P.; Jasimin A.; Ng L.Y.; Tan H.L.
Performance evaluation on ultrafiltration as tertiary treatment for rubber glove wastewater
author_facet Lim Y.P.; Jasimin A.; Ng L.Y.; Tan H.L.
author_sort Lim Y.P.; Jasimin A.; Ng L.Y.; Tan H.L.
title Performance evaluation on ultrafiltration as tertiary treatment for rubber glove wastewater
title_short Performance evaluation on ultrafiltration as tertiary treatment for rubber glove wastewater
title_full Performance evaluation on ultrafiltration as tertiary treatment for rubber glove wastewater
title_fullStr Performance evaluation on ultrafiltration as tertiary treatment for rubber glove wastewater
title_full_unstemmed Performance evaluation on ultrafiltration as tertiary treatment for rubber glove wastewater
title_sort Performance evaluation on ultrafiltration as tertiary treatment for rubber glove wastewater
publishDate 2022
container_title Materials Today: Proceedings
container_volume 63
container_issue
doi_str_mv 10.1016/j.matpr.2022.02.454
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85126781771&doi=10.1016%2fj.matpr.2022.02.454&partnerID=40&md5=cf62f13ca654eba4b0bac350c91bd124
description Ultrafiltration (UF) is a promising treatment solution used for tertiary treatment of industrial wastewater. However, membrane fouling is the major problem which limits the performance of the UF in industry. In the present study, the operational and separation performane of ultrafiltration of biologically treated rubber glove wastewater were carried out using innovative developed organic metal membranes. Two types of commercial PolyCera® Titan (70 kDa) and PolyCera® Hydro (100 kDa) flat sheet UF membrane were applied for tertiary treatment of rubber glove wastewater. The physicochemical properties of influent and UF membranes were characterized before and after the treatment process. PolyCera® Titan membranes have slightly higher hydrophobicity, lower permeability and lower fouling tendency as compared to PolyCera® Hydro membrane. PolyCera® Titan gave higher COD, TSS, and color rejection, observed at 66.9%, 73.3%, and 82.4%, respectively. The permeate quality conformed with the regulatory discharge standard, except for the PolyCera® Hydro membrane in which the COD value surpassed the permissible limit. With its promising performance, PolyCera® membranes have great potential to reduce pollutant loading in the wastewater for efficient rubber glove wastewater treatment. © 2022
publisher Elsevier Ltd
issn 22147853
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1823296161238220800