Development of an optical ph measurement system based on colorimetric effect

This paper proposed an optical pH measurement system developed to measure the changes of pH levels based on colorimetric reactions with phenol red reagent. The optical sensing was achieved through the implementation of a pair of light emitting diode (LED) and photodiode. The detection mechanism was...

Full description

Bibliographic Details
Published in:Indonesian Journal of Electrical Engineering and Computer Science
Main Author: Mustafa P.N.S.M.; Azam A.S.; Sulaiman M.S.; Omar A.F.; Rahman M.F.A.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85117717214&doi=10.11591%2fijeecs.v24.i2.pp728-735&partnerID=40&md5=27b2a3251f20258c59f94e78eabd0038
id 2-s2.0-85117717214
spelling 2-s2.0-85117717214
Mustafa P.N.S.M.; Azam A.S.; Sulaiman M.S.; Omar A.F.; Rahman M.F.A.
Development of an optical ph measurement system based on colorimetric effect
2021
Indonesian Journal of Electrical Engineering and Computer Science
24
2
10.11591/ijeecs.v24.i2.pp728-735
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85117717214&doi=10.11591%2fijeecs.v24.i2.pp728-735&partnerID=40&md5=27b2a3251f20258c59f94e78eabd0038
This paper proposed an optical pH measurement system developed to measure the changes of pH levels based on colorimetric reactions with phenol red reagent. The optical sensing was achieved through the implementation of a pair of light emitting diode (LED) and photodiode. The detection mechanism was based on different absorbance of light intensity at pH values of 2.36, 8.32, 9.08 and 12.83. The data processing method was carried out using LabVIEW software and interfaced with NI USB DAQ 6008. The measured voltage showed a good correlation in relation to the pH level with R2 equals to 0.9624. This relationship was used as a calibration curve in the final system testing. The final measurement of pH showed a good agreement between the actual and measured values with an error of less than 5%, thus indicating the reliability of the proposed system. © 2021 Institute of Advanced Engineering and Science. All rights reserved.
Institute of Advanced Engineering and Science
25024752
English
Article
All Open Access; Gold Open Access
author Mustafa P.N.S.M.; Azam A.S.; Sulaiman M.S.; Omar A.F.; Rahman M.F.A.
spellingShingle Mustafa P.N.S.M.; Azam A.S.; Sulaiman M.S.; Omar A.F.; Rahman M.F.A.
Development of an optical ph measurement system based on colorimetric effect
author_facet Mustafa P.N.S.M.; Azam A.S.; Sulaiman M.S.; Omar A.F.; Rahman M.F.A.
author_sort Mustafa P.N.S.M.; Azam A.S.; Sulaiman M.S.; Omar A.F.; Rahman M.F.A.
title Development of an optical ph measurement system based on colorimetric effect
title_short Development of an optical ph measurement system based on colorimetric effect
title_full Development of an optical ph measurement system based on colorimetric effect
title_fullStr Development of an optical ph measurement system based on colorimetric effect
title_full_unstemmed Development of an optical ph measurement system based on colorimetric effect
title_sort Development of an optical ph measurement system based on colorimetric effect
publishDate 2021
container_title Indonesian Journal of Electrical Engineering and Computer Science
container_volume 24
container_issue 2
doi_str_mv 10.11591/ijeecs.v24.i2.pp728-735
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85117717214&doi=10.11591%2fijeecs.v24.i2.pp728-735&partnerID=40&md5=27b2a3251f20258c59f94e78eabd0038
description This paper proposed an optical pH measurement system developed to measure the changes of pH levels based on colorimetric reactions with phenol red reagent. The optical sensing was achieved through the implementation of a pair of light emitting diode (LED) and photodiode. The detection mechanism was based on different absorbance of light intensity at pH values of 2.36, 8.32, 9.08 and 12.83. The data processing method was carried out using LabVIEW software and interfaced with NI USB DAQ 6008. The measured voltage showed a good correlation in relation to the pH level with R2 equals to 0.9624. This relationship was used as a calibration curve in the final system testing. The final measurement of pH showed a good agreement between the actual and measured values with an error of less than 5%, thus indicating the reliability of the proposed system. © 2021 Institute of Advanced Engineering and Science. All rights reserved.
publisher Institute of Advanced Engineering and Science
issn 25024752
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809678027354800128