Identification of Source Neutral-To-Earth-Voltage (NTEV) Rise in the Commercial Building

This paper presents a novel technique to identify the spot area of neutral-To-earth-voltage (NTEV) rise due to the problem of loose neutral termination (LT) in the commercial building. This technique is proposed to pin-point the spot area of problem either on the upstream or downstream side of measu...

Full description

Bibliographic Details
Published in:ICPEA 2021 - 2021 IEEE International Conference in Power Engineering Application
Main Author: Talib Mat Yusoh M.A.; Abidin A.F.; Zin N.M.; Hamid Z.A.; Mohammad N.N.; Nik Ali N.H.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85106398401&doi=10.1109%2fICPEA51500.2021.9417848&partnerID=40&md5=4905b78ca3340ce3f558ae1ae44a1833
id 2-s2.0-85106398401
spelling 2-s2.0-85106398401
Talib Mat Yusoh M.A.; Abidin A.F.; Zin N.M.; Hamid Z.A.; Mohammad N.N.; Nik Ali N.H.
Identification of Source Neutral-To-Earth-Voltage (NTEV) Rise in the Commercial Building
2021
ICPEA 2021 - 2021 IEEE International Conference in Power Engineering Application


10.1109/ICPEA51500.2021.9417848
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85106398401&doi=10.1109%2fICPEA51500.2021.9417848&partnerID=40&md5=4905b78ca3340ce3f558ae1ae44a1833
This paper presents a novel technique to identify the spot area of neutral-To-earth-voltage (NTEV) rise due to the problem of loose neutral termination (LT) in the commercial building. This technique is proposed to pin-point the spot area of problem either on the upstream or downstream side of measurement spot. In addition, this paper only focusing to the problem on the commercial building which comprise three-phase four wire conductor system. The results show the location of NTEV rise can be detected properly by using Fourier Transform (FT) which is the main core in a proposed technique. The NTEV rise due to the LT is one of the dominant problems in power quality because that problem give an adverse effect to the network distribution system where heating on the conductor cable, stray voltage, fire on the wiring system and lifetime of electrical appliances becoming shorter and shorter. © 2021 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Talib Mat Yusoh M.A.; Abidin A.F.; Zin N.M.; Hamid Z.A.; Mohammad N.N.; Nik Ali N.H.
spellingShingle Talib Mat Yusoh M.A.; Abidin A.F.; Zin N.M.; Hamid Z.A.; Mohammad N.N.; Nik Ali N.H.
Identification of Source Neutral-To-Earth-Voltage (NTEV) Rise in the Commercial Building
author_facet Talib Mat Yusoh M.A.; Abidin A.F.; Zin N.M.; Hamid Z.A.; Mohammad N.N.; Nik Ali N.H.
author_sort Talib Mat Yusoh M.A.; Abidin A.F.; Zin N.M.; Hamid Z.A.; Mohammad N.N.; Nik Ali N.H.
title Identification of Source Neutral-To-Earth-Voltage (NTEV) Rise in the Commercial Building
title_short Identification of Source Neutral-To-Earth-Voltage (NTEV) Rise in the Commercial Building
title_full Identification of Source Neutral-To-Earth-Voltage (NTEV) Rise in the Commercial Building
title_fullStr Identification of Source Neutral-To-Earth-Voltage (NTEV) Rise in the Commercial Building
title_full_unstemmed Identification of Source Neutral-To-Earth-Voltage (NTEV) Rise in the Commercial Building
title_sort Identification of Source Neutral-To-Earth-Voltage (NTEV) Rise in the Commercial Building
publishDate 2021
container_title ICPEA 2021 - 2021 IEEE International Conference in Power Engineering Application
container_volume
container_issue
doi_str_mv 10.1109/ICPEA51500.2021.9417848
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85106398401&doi=10.1109%2fICPEA51500.2021.9417848&partnerID=40&md5=4905b78ca3340ce3f558ae1ae44a1833
description This paper presents a novel technique to identify the spot area of neutral-To-earth-voltage (NTEV) rise due to the problem of loose neutral termination (LT) in the commercial building. This technique is proposed to pin-point the spot area of problem either on the upstream or downstream side of measurement spot. In addition, this paper only focusing to the problem on the commercial building which comprise three-phase four wire conductor system. The results show the location of NTEV rise can be detected properly by using Fourier Transform (FT) which is the main core in a proposed technique. The NTEV rise due to the LT is one of the dominant problems in power quality because that problem give an adverse effect to the network distribution system where heating on the conductor cable, stray voltage, fire on the wiring system and lifetime of electrical appliances becoming shorter and shorter. © 2021 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677685573550080