Solid Phase Extraction Method for the Determination of Atrazine and Cyanazine in Water Samples

Triazine is one of the herbicides group that is widely used in agriculture that acts as an inhibitor for the growth of unwanted weeds in plants. The use of this herbicide on plants is absorbed by the soil and flows into a nearby water system. This research focused on two types of triazines, namely a...

Full description

Bibliographic Details
Published in:ASM Science Journal
Main Author: Abidin N.A.Z.; Abdullah A.; Kassim N.S.A.; Pungot N.H.
Format: Article
Language:English
Published: Akademi Sains Malaysia 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85104820669&doi=10.32802%2fasmscj.2020.631&partnerID=40&md5=806d37384fb8d89cb03d5892cb5828c7
id 2-s2.0-85104820669
spelling 2-s2.0-85104820669
Abidin N.A.Z.; Abdullah A.; Kassim N.S.A.; Pungot N.H.
Solid Phase Extraction Method for the Determination of Atrazine and Cyanazine in Water Samples
2021
ASM Science Journal
14

10.32802/asmscj.2020.631
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85104820669&doi=10.32802%2fasmscj.2020.631&partnerID=40&md5=806d37384fb8d89cb03d5892cb5828c7
Triazine is one of the herbicides group that is widely used in agriculture that acts as an inhibitor for the growth of unwanted weeds in plants. The use of this herbicide on plants is absorbed by the soil and flows into a nearby water system. This research focused on two types of triazines, namely atrazine and cyanazine. This research aims to extract this type of triazine herbicides and to determine their concentration in water samples. It was quantified by using gas chromatography-electron capture detector (GC-ECD). Solid phase extraction (SPE) method was applied to extract herbicides from water samples. The results indicate that all the samples contained atrazine and cyanazine. Studies in the range of 0.5 -25 mg/L achieved good linearity with good correlation of determination, r2 value of 0.9922 -0.9982 mg/L. Relative standard deviations (RSD) for triplicate analysis of the samples were less than 10.0%. The limit of detection (LODs) and limit of quantification (LOQs) of cyanazine and atrazine were found, ranging from 3.33 – 6.67 μg/L and 11.09 – 20.10 μg/L, respectively. The recoveries of the triazine herbicides studied in water samples ranged from 82.5% to 107.6%. The developed method exhibited excellent clean-up capability and was successfully applied for determining triazine herbicide residues in water samples. © 2021, ASM Science Journal. All Rigths Reserved.
Akademi Sains Malaysia
18236782
English
Article
All Open Access; Gold Open Access
author Abidin N.A.Z.; Abdullah A.; Kassim N.S.A.; Pungot N.H.
spellingShingle Abidin N.A.Z.; Abdullah A.; Kassim N.S.A.; Pungot N.H.
Solid Phase Extraction Method for the Determination of Atrazine and Cyanazine in Water Samples
author_facet Abidin N.A.Z.; Abdullah A.; Kassim N.S.A.; Pungot N.H.
author_sort Abidin N.A.Z.; Abdullah A.; Kassim N.S.A.; Pungot N.H.
title Solid Phase Extraction Method for the Determination of Atrazine and Cyanazine in Water Samples
title_short Solid Phase Extraction Method for the Determination of Atrazine and Cyanazine in Water Samples
title_full Solid Phase Extraction Method for the Determination of Atrazine and Cyanazine in Water Samples
title_fullStr Solid Phase Extraction Method for the Determination of Atrazine and Cyanazine in Water Samples
title_full_unstemmed Solid Phase Extraction Method for the Determination of Atrazine and Cyanazine in Water Samples
title_sort Solid Phase Extraction Method for the Determination of Atrazine and Cyanazine in Water Samples
publishDate 2021
container_title ASM Science Journal
container_volume 14
container_issue
doi_str_mv 10.32802/asmscj.2020.631
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85104820669&doi=10.32802%2fasmscj.2020.631&partnerID=40&md5=806d37384fb8d89cb03d5892cb5828c7
description Triazine is one of the herbicides group that is widely used in agriculture that acts as an inhibitor for the growth of unwanted weeds in plants. The use of this herbicide on plants is absorbed by the soil and flows into a nearby water system. This research focused on two types of triazines, namely atrazine and cyanazine. This research aims to extract this type of triazine herbicides and to determine their concentration in water samples. It was quantified by using gas chromatography-electron capture detector (GC-ECD). Solid phase extraction (SPE) method was applied to extract herbicides from water samples. The results indicate that all the samples contained atrazine and cyanazine. Studies in the range of 0.5 -25 mg/L achieved good linearity with good correlation of determination, r2 value of 0.9922 -0.9982 mg/L. Relative standard deviations (RSD) for triplicate analysis of the samples were less than 10.0%. The limit of detection (LODs) and limit of quantification (LOQs) of cyanazine and atrazine were found, ranging from 3.33 – 6.67 μg/L and 11.09 – 20.10 μg/L, respectively. The recoveries of the triazine herbicides studied in water samples ranged from 82.5% to 107.6%. The developed method exhibited excellent clean-up capability and was successfully applied for determining triazine herbicide residues in water samples. © 2021, ASM Science Journal. All Rigths Reserved.
publisher Akademi Sains Malaysia
issn 18236782
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677895212204032