Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison
The content of heavy metal ions in industrial wastewater could be a great threat to the environment and humans’ health. Owing to this issue, the emulsion liquid membrane (ELM) is proposed as an effective technique to remove heavy metal from aqueous solution. The current work intended to compare the...
Published in: | IOP Conference Series: Earth and Environmental Science |
---|---|
Main Author: | |
Format: | Conference paper |
Language: | English |
Published: |
IOP Publishing Ltd
2020
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100026327&doi=10.1088%2f1755-1315%2f616%2f1%2f012077&partnerID=40&md5=8598c01ab323d3dc20ea54375cf63951 |
id |
2-s2.0-85100026327 |
---|---|
spelling |
2-s2.0-85100026327 Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W. Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison 2020 IOP Conference Series: Earth and Environmental Science 616 1 10.1088/1755-1315/616/1/012077 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100026327&doi=10.1088%2f1755-1315%2f616%2f1%2f012077&partnerID=40&md5=8598c01ab323d3dc20ea54375cf63951 The content of heavy metal ions in industrial wastewater could be a great threat to the environment and humans’ health. Owing to this issue, the emulsion liquid membrane (ELM) is proposed as an effective technique to remove heavy metal from aqueous solution. The current work intended to compare the performance of ELM extraction using two dispersion tools; conventional stirrer and Taylor-Couette Column (TCC). The effect of stirring speed and extraction time of both devices on the removal efficiency of copper and cadmium will be looked at. Results obtained demonstrated a huge reduction in extraction time to simultaneously remove the two types of heavy metals. The maximum extraction efficiency in conventional stirrer for both copper and cadmium were found at 400 rpm in 20 mins (99.52%) and 10 mins (95.47%), respectively. Meanwhile, the highest efficiency in TCC for copper was found to be slightly lower although it offers shorter time for the performance to peak. 200 rpm of outer cylinder is required to achieve 96.38% while 600 rpm is required to remove as high as 81.59% of cadmium. The extraction time required to obtain the maximum removal in TCC is 5 mins and 3 mins for copper and cadmium, respectively. © 2020 Institute of Physics Publishing. All rights reserved. IOP Publishing Ltd 17551307 English Conference paper All Open Access; Gold Open Access |
author |
Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W. |
spellingShingle |
Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W. Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison |
author_facet |
Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W. |
author_sort |
Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W. |
title |
Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison |
title_short |
Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison |
title_full |
Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison |
title_fullStr |
Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison |
title_full_unstemmed |
Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison |
title_sort |
Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison |
publishDate |
2020 |
container_title |
IOP Conference Series: Earth and Environmental Science |
container_volume |
616 |
container_issue |
1 |
doi_str_mv |
10.1088/1755-1315/616/1/012077 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100026327&doi=10.1088%2f1755-1315%2f616%2f1%2f012077&partnerID=40&md5=8598c01ab323d3dc20ea54375cf63951 |
description |
The content of heavy metal ions in industrial wastewater could be a great threat to the environment and humans’ health. Owing to this issue, the emulsion liquid membrane (ELM) is proposed as an effective technique to remove heavy metal from aqueous solution. The current work intended to compare the performance of ELM extraction using two dispersion tools; conventional stirrer and Taylor-Couette Column (TCC). The effect of stirring speed and extraction time of both devices on the removal efficiency of copper and cadmium will be looked at. Results obtained demonstrated a huge reduction in extraction time to simultaneously remove the two types of heavy metals. The maximum extraction efficiency in conventional stirrer for both copper and cadmium were found at 400 rpm in 20 mins (99.52%) and 10 mins (95.47%), respectively. Meanwhile, the highest efficiency in TCC for copper was found to be slightly lower although it offers shorter time for the performance to peak. 200 rpm of outer cylinder is required to achieve 96.38% while 600 rpm is required to remove as high as 81.59% of cadmium. The extraction time required to obtain the maximum removal in TCC is 5 mins and 3 mins for copper and cadmium, respectively. © 2020 Institute of Physics Publishing. All rights reserved. |