Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison

The content of heavy metal ions in industrial wastewater could be a great threat to the environment and humans’ health. Owing to this issue, the emulsion liquid membrane (ELM) is proposed as an effective technique to remove heavy metal from aqueous solution. The current work intended to compare the...

Full description

Bibliographic Details
Published in:IOP Conference Series: Earth and Environmental Science
Main Author: Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W.
Format: Conference paper
Language:English
Published: IOP Publishing Ltd 2020
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100026327&doi=10.1088%2f1755-1315%2f616%2f1%2f012077&partnerID=40&md5=8598c01ab323d3dc20ea54375cf63951
id 2-s2.0-85100026327
spelling 2-s2.0-85100026327
Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W.
Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison
2020
IOP Conference Series: Earth and Environmental Science
616
1
10.1088/1755-1315/616/1/012077
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100026327&doi=10.1088%2f1755-1315%2f616%2f1%2f012077&partnerID=40&md5=8598c01ab323d3dc20ea54375cf63951
The content of heavy metal ions in industrial wastewater could be a great threat to the environment and humans’ health. Owing to this issue, the emulsion liquid membrane (ELM) is proposed as an effective technique to remove heavy metal from aqueous solution. The current work intended to compare the performance of ELM extraction using two dispersion tools; conventional stirrer and Taylor-Couette Column (TCC). The effect of stirring speed and extraction time of both devices on the removal efficiency of copper and cadmium will be looked at. Results obtained demonstrated a huge reduction in extraction time to simultaneously remove the two types of heavy metals. The maximum extraction efficiency in conventional stirrer for both copper and cadmium were found at 400 rpm in 20 mins (99.52%) and 10 mins (95.47%), respectively. Meanwhile, the highest efficiency in TCC for copper was found to be slightly lower although it offers shorter time for the performance to peak. 200 rpm of outer cylinder is required to achieve 96.38% while 600 rpm is required to remove as high as 81.59% of cadmium. The extraction time required to obtain the maximum removal in TCC is 5 mins and 3 mins for copper and cadmium, respectively. © 2020 Institute of Physics Publishing. All rights reserved.
IOP Publishing Ltd
17551307
English
Conference paper
All Open Access; Gold Open Access
author Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W.
spellingShingle Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W.
Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison
author_facet Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W.
author_sort Abd Khalil A.T.; Shah Buddin M.M.H.; Mokhtar N.F.; Puasa S.W.
title Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison
title_short Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison
title_full Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison
title_fullStr Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison
title_full_unstemmed Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison
title_sort Performance evaluation of emulsion liquid membrane for simultaneous copper and cadmium removal: Dispersion tool comparison
publishDate 2020
container_title IOP Conference Series: Earth and Environmental Science
container_volume 616
container_issue 1
doi_str_mv 10.1088/1755-1315/616/1/012077
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100026327&doi=10.1088%2f1755-1315%2f616%2f1%2f012077&partnerID=40&md5=8598c01ab323d3dc20ea54375cf63951
description The content of heavy metal ions in industrial wastewater could be a great threat to the environment and humans’ health. Owing to this issue, the emulsion liquid membrane (ELM) is proposed as an effective technique to remove heavy metal from aqueous solution. The current work intended to compare the performance of ELM extraction using two dispersion tools; conventional stirrer and Taylor-Couette Column (TCC). The effect of stirring speed and extraction time of both devices on the removal efficiency of copper and cadmium will be looked at. Results obtained demonstrated a huge reduction in extraction time to simultaneously remove the two types of heavy metals. The maximum extraction efficiency in conventional stirrer for both copper and cadmium were found at 400 rpm in 20 mins (99.52%) and 10 mins (95.47%), respectively. Meanwhile, the highest efficiency in TCC for copper was found to be slightly lower although it offers shorter time for the performance to peak. 200 rpm of outer cylinder is required to achieve 96.38% while 600 rpm is required to remove as high as 81.59% of cadmium. The extraction time required to obtain the maximum removal in TCC is 5 mins and 3 mins for copper and cadmium, respectively. © 2020 Institute of Physics Publishing. All rights reserved.
publisher IOP Publishing Ltd
issn 17551307
language English
format Conference paper
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677895290847232