Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions
This study aims to evaluate the diagnostic accuracy of digital breast tomosynthesis-guided vacuum assisted breast biopsy (DBT-VABB) of screening detected suspicious mammographic abnormalities comprising of calcifications, asymmetric densities, architectural distortions and spiculated masses. In this...
Published in: | Scientific Reports |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
Nature Research
2021
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85098950415&doi=10.1038%2fs41598-020-80124-4&partnerID=40&md5=bea978ce8338d46fb223e2f4909f2c29 |
id |
2-s2.0-85098950415 |
---|---|
spelling |
2-s2.0-85098950415 Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K. Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions 2021 Scientific Reports 11 1 10.1038/s41598-020-80124-4 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85098950415&doi=10.1038%2fs41598-020-80124-4&partnerID=40&md5=bea978ce8338d46fb223e2f4909f2c29 This study aims to evaluate the diagnostic accuracy of digital breast tomosynthesis-guided vacuum assisted breast biopsy (DBT-VABB) of screening detected suspicious mammographic abnormalities comprising of calcifications, asymmetric densities, architectural distortions and spiculated masses. In this institutionally approved study, a total of 170 (n = 170) DBT-VABB were performed, 153 (90%) were for calcifications, 8 (4.7%) for spiculated mass, 5 (2.9%) for asymmetric density and 4 (2.4%) for architectural distortion. All these lesions were not detected on the corresponding ultrasound. Histopathology results revealed 140 (82.4%) benign, 9 (5.3%) borderline and 21 (12.4%) malignant lesions. The total upgrade rate at surgery was 40% for atypical ductal hyperplasia and 5.9% for ductal carcinoma in-situ. 3.6% discordant benign lesions showed no upgrade. DBT-VABB showed 100% specificity, 91.3% sensitivity and 100% positive predictive value (PPV) for detecting malignant lesions. The negative predictive value (NPV) was 80%. 2 (1.2%) patients had mild complications and 1 (0.6%) had severe pain. Our study showed that DBT-VABB was a safe and reliable method, with high sensitivity, specificity, PPV and NPV in the diagnosis of non-palpable benign and malignant breast lesions. Our data also confirmed the accuracy of DBT-VABB in detecting malignant lesions and we suggest further surgical excision in borderline lesions for a more accurate diagnostic evaluation. © 2021, The Author(s). Nature Research 20452322 English Article All Open Access; Gold Open Access |
author |
Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K. |
spellingShingle |
Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K. Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions |
author_facet |
Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K. |
author_sort |
Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K. |
title |
Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions |
title_short |
Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions |
title_full |
Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions |
title_fullStr |
Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions |
title_full_unstemmed |
Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions |
title_sort |
Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions |
publishDate |
2021 |
container_title |
Scientific Reports |
container_volume |
11 |
container_issue |
1 |
doi_str_mv |
10.1038/s41598-020-80124-4 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85098950415&doi=10.1038%2fs41598-020-80124-4&partnerID=40&md5=bea978ce8338d46fb223e2f4909f2c29 |
description |
This study aims to evaluate the diagnostic accuracy of digital breast tomosynthesis-guided vacuum assisted breast biopsy (DBT-VABB) of screening detected suspicious mammographic abnormalities comprising of calcifications, asymmetric densities, architectural distortions and spiculated masses. In this institutionally approved study, a total of 170 (n = 170) DBT-VABB were performed, 153 (90%) were for calcifications, 8 (4.7%) for spiculated mass, 5 (2.9%) for asymmetric density and 4 (2.4%) for architectural distortion. All these lesions were not detected on the corresponding ultrasound. Histopathology results revealed 140 (82.4%) benign, 9 (5.3%) borderline and 21 (12.4%) malignant lesions. The total upgrade rate at surgery was 40% for atypical ductal hyperplasia and 5.9% for ductal carcinoma in-situ. 3.6% discordant benign lesions showed no upgrade. DBT-VABB showed 100% specificity, 91.3% sensitivity and 100% positive predictive value (PPV) for detecting malignant lesions. The negative predictive value (NPV) was 80%. 2 (1.2%) patients had mild complications and 1 (0.6%) had severe pain. Our study showed that DBT-VABB was a safe and reliable method, with high sensitivity, specificity, PPV and NPV in the diagnosis of non-palpable benign and malignant breast lesions. Our data also confirmed the accuracy of DBT-VABB in detecting malignant lesions and we suggest further surgical excision in borderline lesions for a more accurate diagnostic evaluation. © 2021, The Author(s). |
publisher |
Nature Research |
issn |
20452322 |
language |
English |
format |
Article |
accesstype |
All Open Access; Gold Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1809678158697332736 |