Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions

This study aims to evaluate the diagnostic accuracy of digital breast tomosynthesis-guided vacuum assisted breast biopsy (DBT-VABB) of screening detected suspicious mammographic abnormalities comprising of calcifications, asymmetric densities, architectural distortions and spiculated masses. In this...

Full description

Bibliographic Details
Published in:Scientific Reports
Main Author: Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K.
Format: Article
Language:English
Published: Nature Research 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85098950415&doi=10.1038%2fs41598-020-80124-4&partnerID=40&md5=bea978ce8338d46fb223e2f4909f2c29
id 2-s2.0-85098950415
spelling 2-s2.0-85098950415
Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K.
Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions
2021
Scientific Reports
11
1
10.1038/s41598-020-80124-4
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85098950415&doi=10.1038%2fs41598-020-80124-4&partnerID=40&md5=bea978ce8338d46fb223e2f4909f2c29
This study aims to evaluate the diagnostic accuracy of digital breast tomosynthesis-guided vacuum assisted breast biopsy (DBT-VABB) of screening detected suspicious mammographic abnormalities comprising of calcifications, asymmetric densities, architectural distortions and spiculated masses. In this institutionally approved study, a total of 170 (n = 170) DBT-VABB were performed, 153 (90%) were for calcifications, 8 (4.7%) for spiculated mass, 5 (2.9%) for asymmetric density and 4 (2.4%) for architectural distortion. All these lesions were not detected on the corresponding ultrasound. Histopathology results revealed 140 (82.4%) benign, 9 (5.3%) borderline and 21 (12.4%) malignant lesions. The total upgrade rate at surgery was 40% for atypical ductal hyperplasia and 5.9% for ductal carcinoma in-situ. 3.6% discordant benign lesions showed no upgrade. DBT-VABB showed 100% specificity, 91.3% sensitivity and 100% positive predictive value (PPV) for detecting malignant lesions. The negative predictive value (NPV) was 80%. 2 (1.2%) patients had mild complications and 1 (0.6%) had severe pain. Our study showed that DBT-VABB was a safe and reliable method, with high sensitivity, specificity, PPV and NPV in the diagnosis of non-palpable benign and malignant breast lesions. Our data also confirmed the accuracy of DBT-VABB in detecting malignant lesions and we suggest further surgical excision in borderline lesions for a more accurate diagnostic evaluation. © 2021, The Author(s).
Nature Research
20452322
English
Article
All Open Access; Gold Open Access
author Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K.
spellingShingle Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K.
Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions
author_facet Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K.
author_sort Bohan S.; Ramli Hamid M.T.; Chan W.Y.; Vijayananthan A.; Ramli N.; Kaur S.; Rahmat K.
title Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions
title_short Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions
title_full Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions
title_fullStr Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions
title_full_unstemmed Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions
title_sort Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions
publishDate 2021
container_title Scientific Reports
container_volume 11
container_issue 1
doi_str_mv 10.1038/s41598-020-80124-4
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85098950415&doi=10.1038%2fs41598-020-80124-4&partnerID=40&md5=bea978ce8338d46fb223e2f4909f2c29
description This study aims to evaluate the diagnostic accuracy of digital breast tomosynthesis-guided vacuum assisted breast biopsy (DBT-VABB) of screening detected suspicious mammographic abnormalities comprising of calcifications, asymmetric densities, architectural distortions and spiculated masses. In this institutionally approved study, a total of 170 (n = 170) DBT-VABB were performed, 153 (90%) were for calcifications, 8 (4.7%) for spiculated mass, 5 (2.9%) for asymmetric density and 4 (2.4%) for architectural distortion. All these lesions were not detected on the corresponding ultrasound. Histopathology results revealed 140 (82.4%) benign, 9 (5.3%) borderline and 21 (12.4%) malignant lesions. The total upgrade rate at surgery was 40% for atypical ductal hyperplasia and 5.9% for ductal carcinoma in-situ. 3.6% discordant benign lesions showed no upgrade. DBT-VABB showed 100% specificity, 91.3% sensitivity and 100% positive predictive value (PPV) for detecting malignant lesions. The negative predictive value (NPV) was 80%. 2 (1.2%) patients had mild complications and 1 (0.6%) had severe pain. Our study showed that DBT-VABB was a safe and reliable method, with high sensitivity, specificity, PPV and NPV in the diagnosis of non-palpable benign and malignant breast lesions. Our data also confirmed the accuracy of DBT-VABB in detecting malignant lesions and we suggest further surgical excision in borderline lesions for a more accurate diagnostic evaluation. © 2021, The Author(s).
publisher Nature Research
issn 20452322
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809678158697332736