Eye blinking patterns, corneal staining and compliance in a group of soft contact lens wearers; [Corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh]

Many factors influence the success of contact lens wear, including lens surface moisture, which is affected by blinking. This study was conducted to determine the eye blinking patterns, corneal staining, and compliance in a group of soft contact lens (CL) wearers. Forty-one soft CL wearers and 41 ag...

Full description

Bibliographic Details
Published in:Sains Malaysiana
Main Author: Ishak B.; Saad N.S.; Lee L.S.; Daud N.M.; Ali B.M.; Mohidin N.
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2020
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85097636538&doi=10.17576%2fjsm-2020-4911-17&partnerID=40&md5=4ad0ea1520043071a0d1bcda07344496
id 2-s2.0-85097636538
spelling 2-s2.0-85097636538
Ishak B.; Saad N.S.; Lee L.S.; Daud N.M.; Ali B.M.; Mohidin N.
Eye blinking patterns, corneal staining and compliance in a group of soft contact lens wearers; [Corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh]
2020
Sains Malaysiana
49
11
10.17576/jsm-2020-4911-17
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85097636538&doi=10.17576%2fjsm-2020-4911-17&partnerID=40&md5=4ad0ea1520043071a0d1bcda07344496
Many factors influence the success of contact lens wear, including lens surface moisture, which is affected by blinking. This study was conducted to determine the eye blinking patterns, corneal staining, and compliance in a group of soft contact lens (CL) wearers. Forty-one soft CL wearers and 41 age-matched control subjects (non-CL wearers) were recruited in this study. Blinking patterns were assessed with a digital camera attached to a slit lamp biomicroscope. Corneal staining was graded using Institute for Eye Research (IER) grading scale with 0.1 increments. The subject’s compliance level was determined using a questionnaire. There was no difference in eye blinking patterns between the CL wearers and control group (Mann-Whitney, p = 0.231). The average grades of corneal staining in CL wearers and control group were 0.38 ± 0.39 and 0.01 ± 0.08 unit, respectively. There was a significant difference in corneal staining between the two groups (Mann-Whitney, p = 0.021). A significant positive correlation was found between blinking patterns and corneal staining (Spearman ρ = 0.378, p = 0.015). Our results also showed that 63.4% of the CL wearers had good compliance towards lens care. In our multiple linear regression analysis, blinking patterns contributed significantly to corneal staining (B = 0.140, p = 0.015), while compliance level did not (B = -0.038, p = 0.471). Overall, eye blinking patterns in CL wearers influenced the risk of corneal staining. © 2020 Penerbit Universiti Kebangsaan Malaysia. All rights reserved.
Penerbit Universiti Kebangsaan Malaysia
1266039
English
Article
All Open Access; Gold Open Access
author Ishak B.; Saad N.S.; Lee L.S.; Daud N.M.; Ali B.M.; Mohidin N.
spellingShingle Ishak B.; Saad N.S.; Lee L.S.; Daud N.M.; Ali B.M.; Mohidin N.
Eye blinking patterns, corneal staining and compliance in a group of soft contact lens wearers; [Corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh]
author_facet Ishak B.; Saad N.S.; Lee L.S.; Daud N.M.; Ali B.M.; Mohidin N.
author_sort Ishak B.; Saad N.S.; Lee L.S.; Daud N.M.; Ali B.M.; Mohidin N.
title Eye blinking patterns, corneal staining and compliance in a group of soft contact lens wearers; [Corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh]
title_short Eye blinking patterns, corneal staining and compliance in a group of soft contact lens wearers; [Corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh]
title_full Eye blinking patterns, corneal staining and compliance in a group of soft contact lens wearers; [Corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh]
title_fullStr Eye blinking patterns, corneal staining and compliance in a group of soft contact lens wearers; [Corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh]
title_full_unstemmed Eye blinking patterns, corneal staining and compliance in a group of soft contact lens wearers; [Corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh]
title_sort Eye blinking patterns, corneal staining and compliance in a group of soft contact lens wearers; [Corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh]
publishDate 2020
container_title Sains Malaysiana
container_volume 49
container_issue 11
doi_str_mv 10.17576/jsm-2020-4911-17
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85097636538&doi=10.17576%2fjsm-2020-4911-17&partnerID=40&md5=4ad0ea1520043071a0d1bcda07344496
description Many factors influence the success of contact lens wear, including lens surface moisture, which is affected by blinking. This study was conducted to determine the eye blinking patterns, corneal staining, and compliance in a group of soft contact lens (CL) wearers. Forty-one soft CL wearers and 41 age-matched control subjects (non-CL wearers) were recruited in this study. Blinking patterns were assessed with a digital camera attached to a slit lamp biomicroscope. Corneal staining was graded using Institute for Eye Research (IER) grading scale with 0.1 increments. The subject’s compliance level was determined using a questionnaire. There was no difference in eye blinking patterns between the CL wearers and control group (Mann-Whitney, p = 0.231). The average grades of corneal staining in CL wearers and control group were 0.38 ± 0.39 and 0.01 ± 0.08 unit, respectively. There was a significant difference in corneal staining between the two groups (Mann-Whitney, p = 0.021). A significant positive correlation was found between blinking patterns and corneal staining (Spearman ρ = 0.378, p = 0.015). Our results also showed that 63.4% of the CL wearers had good compliance towards lens care. In our multiple linear regression analysis, blinking patterns contributed significantly to corneal staining (B = 0.140, p = 0.015), while compliance level did not (B = -0.038, p = 0.471). Overall, eye blinking patterns in CL wearers influenced the risk of corneal staining. © 2020 Penerbit Universiti Kebangsaan Malaysia. All rights reserved.
publisher Penerbit Universiti Kebangsaan Malaysia
issn 1266039
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677895915798528