Integration of LED-based lighting in academic buildings for energy efficiency considerations

This paper presents an assessment by integration of LED T8 tube lamps in academic buildings for energy efficiency considerations. The proposed project was implemented in conjunction with a national mission, national energy efficiency action plan (NEEAP) for 10-year implementation period of 2016-2025...

Full description

Bibliographic Details
Published in:Bulletin of Electrical Engineering and Informatics
Main Author: Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85091098147&doi=10.11591%2feei.v10i1.2513&partnerID=40&md5=17fdf3b0791d686856f28a4c95753899
id 2-s2.0-85091098147
spelling 2-s2.0-85091098147
Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A.
Integration of LED-based lighting in academic buildings for energy efficiency considerations
2021
Bulletin of Electrical Engineering and Informatics
10
1
10.11591/eei.v10i1.2513
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85091098147&doi=10.11591%2feei.v10i1.2513&partnerID=40&md5=17fdf3b0791d686856f28a4c95753899
This paper presents an assessment by integration of LED T8 tube lamps in academic buildings for energy efficiency considerations. The proposed project was implemented in conjunction with a national mission, national energy efficiency action plan (NEEAP) for 10-year implementation period of 2016-2025 in reducing allocation on subsidies for efficient expenditure towards energy-saving measures. A case of study in a real environment at one of the UiTM’s buildings as a target task area has been tested by replacing a LED lighting technology in consideration of current operating costs and power factor performances. From the results, LED T8 tubes have shown a better power factor of 0.89 compared to fluorescent lamps with about 0.61 and primarily driven by economic benefits in terms of cost savings of up to 50% with return-on-investment (ROI) 6 months after installation. By integrating this technology, nearly 50% of the total energy consumption in indoor lighting system could be significantly saved, thus reducing the total cost of electricity bills in the future within the target area. © 2021, Institute of Advanced Engineering and Science. All rights reserved.
Institute of Advanced Engineering and Science
20893191
English
Article
All Open Access; Gold Open Access
author Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A.
spellingShingle Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A.
Integration of LED-based lighting in academic buildings for energy efficiency considerations
author_facet Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A.
author_sort Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A.
title Integration of LED-based lighting in academic buildings for energy efficiency considerations
title_short Integration of LED-based lighting in academic buildings for energy efficiency considerations
title_full Integration of LED-based lighting in academic buildings for energy efficiency considerations
title_fullStr Integration of LED-based lighting in academic buildings for energy efficiency considerations
title_full_unstemmed Integration of LED-based lighting in academic buildings for energy efficiency considerations
title_sort Integration of LED-based lighting in academic buildings for energy efficiency considerations
publishDate 2021
container_title Bulletin of Electrical Engineering and Informatics
container_volume 10
container_issue 1
doi_str_mv 10.11591/eei.v10i1.2513
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85091098147&doi=10.11591%2feei.v10i1.2513&partnerID=40&md5=17fdf3b0791d686856f28a4c95753899
description This paper presents an assessment by integration of LED T8 tube lamps in academic buildings for energy efficiency considerations. The proposed project was implemented in conjunction with a national mission, national energy efficiency action plan (NEEAP) for 10-year implementation period of 2016-2025 in reducing allocation on subsidies for efficient expenditure towards energy-saving measures. A case of study in a real environment at one of the UiTM’s buildings as a target task area has been tested by replacing a LED lighting technology in consideration of current operating costs and power factor performances. From the results, LED T8 tubes have shown a better power factor of 0.89 compared to fluorescent lamps with about 0.61 and primarily driven by economic benefits in terms of cost savings of up to 50% with return-on-investment (ROI) 6 months after installation. By integrating this technology, nearly 50% of the total energy consumption in indoor lighting system could be significantly saved, thus reducing the total cost of electricity bills in the future within the target area. © 2021, Institute of Advanced Engineering and Science. All rights reserved.
publisher Institute of Advanced Engineering and Science
issn 20893191
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677895000391680