Integration of LED-based lighting in academic buildings for energy efficiency considerations
This paper presents an assessment by integration of LED T8 tube lamps in academic buildings for energy efficiency considerations. The proposed project was implemented in conjunction with a national mission, national energy efficiency action plan (NEEAP) for 10-year implementation period of 2016-2025...
Published in: | Bulletin of Electrical Engineering and Informatics |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
Institute of Advanced Engineering and Science
2021
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85091098147&doi=10.11591%2feei.v10i1.2513&partnerID=40&md5=17fdf3b0791d686856f28a4c95753899 |
id |
2-s2.0-85091098147 |
---|---|
spelling |
2-s2.0-85091098147 Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A. Integration of LED-based lighting in academic buildings for energy efficiency considerations 2021 Bulletin of Electrical Engineering and Informatics 10 1 10.11591/eei.v10i1.2513 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85091098147&doi=10.11591%2feei.v10i1.2513&partnerID=40&md5=17fdf3b0791d686856f28a4c95753899 This paper presents an assessment by integration of LED T8 tube lamps in academic buildings for energy efficiency considerations. The proposed project was implemented in conjunction with a national mission, national energy efficiency action plan (NEEAP) for 10-year implementation period of 2016-2025 in reducing allocation on subsidies for efficient expenditure towards energy-saving measures. A case of study in a real environment at one of the UiTM’s buildings as a target task area has been tested by replacing a LED lighting technology in consideration of current operating costs and power factor performances. From the results, LED T8 tubes have shown a better power factor of 0.89 compared to fluorescent lamps with about 0.61 and primarily driven by economic benefits in terms of cost savings of up to 50% with return-on-investment (ROI) 6 months after installation. By integrating this technology, nearly 50% of the total energy consumption in indoor lighting system could be significantly saved, thus reducing the total cost of electricity bills in the future within the target area. © 2021, Institute of Advanced Engineering and Science. All rights reserved. Institute of Advanced Engineering and Science 20893191 English Article All Open Access; Gold Open Access |
author |
Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A. |
spellingShingle |
Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A. Integration of LED-based lighting in academic buildings for energy efficiency considerations |
author_facet |
Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A. |
author_sort |
Hussin M.Z.; Shukor S.F.A.; Sin N.D.M.; Yusof Y.; Nor M.Z.M.; Rahman N.H.A. |
title |
Integration of LED-based lighting in academic buildings for energy efficiency considerations |
title_short |
Integration of LED-based lighting in academic buildings for energy efficiency considerations |
title_full |
Integration of LED-based lighting in academic buildings for energy efficiency considerations |
title_fullStr |
Integration of LED-based lighting in academic buildings for energy efficiency considerations |
title_full_unstemmed |
Integration of LED-based lighting in academic buildings for energy efficiency considerations |
title_sort |
Integration of LED-based lighting in academic buildings for energy efficiency considerations |
publishDate |
2021 |
container_title |
Bulletin of Electrical Engineering and Informatics |
container_volume |
10 |
container_issue |
1 |
doi_str_mv |
10.11591/eei.v10i1.2513 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85091098147&doi=10.11591%2feei.v10i1.2513&partnerID=40&md5=17fdf3b0791d686856f28a4c95753899 |
description |
This paper presents an assessment by integration of LED T8 tube lamps in academic buildings for energy efficiency considerations. The proposed project was implemented in conjunction with a national mission, national energy efficiency action plan (NEEAP) for 10-year implementation period of 2016-2025 in reducing allocation on subsidies for efficient expenditure towards energy-saving measures. A case of study in a real environment at one of the UiTM’s buildings as a target task area has been tested by replacing a LED lighting technology in consideration of current operating costs and power factor performances. From the results, LED T8 tubes have shown a better power factor of 0.89 compared to fluorescent lamps with about 0.61 and primarily driven by economic benefits in terms of cost savings of up to 50% with return-on-investment (ROI) 6 months after installation. By integrating this technology, nearly 50% of the total energy consumption in indoor lighting system could be significantly saved, thus reducing the total cost of electricity bills in the future within the target area. © 2021, Institute of Advanced Engineering and Science. All rights reserved. |
publisher |
Institute of Advanced Engineering and Science |
issn |
20893191 |
language |
English |
format |
Article |
accesstype |
All Open Access; Gold Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1809677895000391680 |