Improvement of endoclip design using 3D CAD approach

Endoscopic clip (endoclip) is a metallic mechanical device used in gastrointestinal endoscopy practices with the intention of close mucosal surfaces deprived of the requirement for surgery and sew up. Nowadays, endoclip is accessible in the market predominantly in single firing mode, where the clip...

Full description

Bibliographic Details
Published in:IOP Conference Series: Materials Science and Engineering
Main Author: Siregar I.; Izham M.I.C.; Ariffin A.C.; Adenan M.S.; Saedon J.B.
Format: Conference paper
Language:English
Published: Institute of Physics Publishing 2020
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85086791353&doi=10.1088%2f1757-899X%2f851%2f1%2f012050&partnerID=40&md5=4735ed72b44dfb36d926cc7abc126c8c
id 2-s2.0-85086791353
spelling 2-s2.0-85086791353
Siregar I.; Izham M.I.C.; Ariffin A.C.; Adenan M.S.; Saedon J.B.
Improvement of endoclip design using 3D CAD approach
2020
IOP Conference Series: Materials Science and Engineering
851
1
10.1088/1757-899X/851/1/012050
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85086791353&doi=10.1088%2f1757-899X%2f851%2f1%2f012050&partnerID=40&md5=4735ed72b44dfb36d926cc7abc126c8c
Endoscopic clip (endoclip) is a metallic mechanical device used in gastrointestinal endoscopy practices with the intention of close mucosal surfaces deprived of the requirement for surgery and sew up. Nowadays, endoclip is accessible in the market predominantly in single firing mode, where the clip can only be used once in a period of process. Due to that, the clip is loaded to its applicator repeatedly during the operation which cause delay for the surgery that can lead to fatality. Therefore, this project aims to develop a multi-firing endoclip cartridge that can reduce the difficulty of reloading the endoclip system to its applicator by improving current design. Three design of multi-firing endoclip cartridges were produced by using different mechanism to apply the endoclip. The casing of the cartridge was designed in cylindrical shape with 40 mm diameter and 68 mm length with CATIA V5 software. These three designs formerly assessed by using decision matrix method for assortment of the best concept design. The result from the decision matrix table shows that design with revolve internal clip holder got the highest decision matrix selection amongst the three designs, advantaging in holding more clips and can reduce operation time compared to the other two designs. © Published under licence by IOP Publishing Ltd.
Institute of Physics Publishing
17578981
English
Conference paper
All Open Access; Gold Open Access
author Siregar I.; Izham M.I.C.; Ariffin A.C.; Adenan M.S.; Saedon J.B.
spellingShingle Siregar I.; Izham M.I.C.; Ariffin A.C.; Adenan M.S.; Saedon J.B.
Improvement of endoclip design using 3D CAD approach
author_facet Siregar I.; Izham M.I.C.; Ariffin A.C.; Adenan M.S.; Saedon J.B.
author_sort Siregar I.; Izham M.I.C.; Ariffin A.C.; Adenan M.S.; Saedon J.B.
title Improvement of endoclip design using 3D CAD approach
title_short Improvement of endoclip design using 3D CAD approach
title_full Improvement of endoclip design using 3D CAD approach
title_fullStr Improvement of endoclip design using 3D CAD approach
title_full_unstemmed Improvement of endoclip design using 3D CAD approach
title_sort Improvement of endoclip design using 3D CAD approach
publishDate 2020
container_title IOP Conference Series: Materials Science and Engineering
container_volume 851
container_issue 1
doi_str_mv 10.1088/1757-899X/851/1/012050
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85086791353&doi=10.1088%2f1757-899X%2f851%2f1%2f012050&partnerID=40&md5=4735ed72b44dfb36d926cc7abc126c8c
description Endoscopic clip (endoclip) is a metallic mechanical device used in gastrointestinal endoscopy practices with the intention of close mucosal surfaces deprived of the requirement for surgery and sew up. Nowadays, endoclip is accessible in the market predominantly in single firing mode, where the clip can only be used once in a period of process. Due to that, the clip is loaded to its applicator repeatedly during the operation which cause delay for the surgery that can lead to fatality. Therefore, this project aims to develop a multi-firing endoclip cartridge that can reduce the difficulty of reloading the endoclip system to its applicator by improving current design. Three design of multi-firing endoclip cartridges were produced by using different mechanism to apply the endoclip. The casing of the cartridge was designed in cylindrical shape with 40 mm diameter and 68 mm length with CATIA V5 software. These three designs formerly assessed by using decision matrix method for assortment of the best concept design. The result from the decision matrix table shows that design with revolve internal clip holder got the highest decision matrix selection amongst the three designs, advantaging in holding more clips and can reduce operation time compared to the other two designs. © Published under licence by IOP Publishing Ltd.
publisher Institute of Physics Publishing
issn 17578981
language English
format Conference paper
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677897955278848