Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep

Background: Cone Beam Computed Tomography (CBCT) is a reliable radiographic modality to assess trabecular bone microarchitecture. The aim of this study was to determine the effect of CBCT image reconstruction parameters, namely, the threshold value and reconstruction voxel size, on trabecular bone m...

Full description

Bibliographic Details
Published in:BMC Oral Health
Main Author: Muhammad A.M.A.; Ibrahim N.; Ahmad R.; Asif M.K.; Radzi Z.; Zaini Z.M.; Razak H.R.A.
Format: Article
Language:English
Published: BioMed Central Ltd. 2020
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079234455&doi=10.1186%2fs12903-020-1035-7&partnerID=40&md5=91c763e60fa37acc03ebb79d271a8fd0
id 2-s2.0-85079234455
spelling 2-s2.0-85079234455
Muhammad A.M.A.; Ibrahim N.; Ahmad R.; Asif M.K.; Radzi Z.; Zaini Z.M.; Razak H.R.A.
Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
2020
BMC Oral Health
20
1
10.1186/s12903-020-1035-7
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079234455&doi=10.1186%2fs12903-020-1035-7&partnerID=40&md5=91c763e60fa37acc03ebb79d271a8fd0
Background: Cone Beam Computed Tomography (CBCT) is a reliable radiographic modality to assess trabecular bone microarchitecture. The aim of this study was to determine the effect of CBCT image reconstruction parameters, namely, the threshold value and reconstruction voxel size, on trabecular bone microstructure assessment. Methods: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 μm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 μm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15). Results: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%. Conclusions: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value. © 2020 The Author(s).
BioMed Central Ltd.
14726831
English
Article
All Open Access; Gold Open Access
author Muhammad A.M.A.; Ibrahim N.; Ahmad R.; Asif M.K.; Radzi Z.; Zaini Z.M.; Razak H.R.A.
spellingShingle Muhammad A.M.A.; Ibrahim N.; Ahmad R.; Asif M.K.; Radzi Z.; Zaini Z.M.; Razak H.R.A.
Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
author_facet Muhammad A.M.A.; Ibrahim N.; Ahmad R.; Asif M.K.; Radzi Z.; Zaini Z.M.; Razak H.R.A.
author_sort Muhammad A.M.A.; Ibrahim N.; Ahmad R.; Asif M.K.; Radzi Z.; Zaini Z.M.; Razak H.R.A.
title Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
title_short Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
title_full Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
title_fullStr Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
title_full_unstemmed Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
title_sort Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
publishDate 2020
container_title BMC Oral Health
container_volume 20
container_issue 1
doi_str_mv 10.1186/s12903-020-1035-7
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079234455&doi=10.1186%2fs12903-020-1035-7&partnerID=40&md5=91c763e60fa37acc03ebb79d271a8fd0
description Background: Cone Beam Computed Tomography (CBCT) is a reliable radiographic modality to assess trabecular bone microarchitecture. The aim of this study was to determine the effect of CBCT image reconstruction parameters, namely, the threshold value and reconstruction voxel size, on trabecular bone microstructure assessment. Methods: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 μm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 μm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15). Results: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%. Conclusions: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value. © 2020 The Author(s).
publisher BioMed Central Ltd.
issn 14726831
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1818940561293312000