Automated monitoring and controlling pH levels for hydroponics cultivation technique

A hydroponics plant can grow healthily with sufficient nutrient, temperature, light, humidity as well as pH level that is indeed vital in ensuring the plants will absorb maximum nutrient elements required. This paper presents automated monitoring and controlling pH levels for the hydroponic cultivat...

Full description

Bibliographic Details
Published in:Indonesian Journal of Electrical Engineering and Computer Science
Main Author: Saaid M.F.; Yassin A.I.M.; Tahir N.M.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2020
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079180911&doi=10.11591%2fijeecs.v18.i3.pp1236-1243&partnerID=40&md5=bd93aabda7096718735ba797940393ba
id 2-s2.0-85079180911
spelling 2-s2.0-85079180911
Saaid M.F.; Yassin A.I.M.; Tahir N.M.
Automated monitoring and controlling pH levels for hydroponics cultivation technique
2020
Indonesian Journal of Electrical Engineering and Computer Science
18
3
10.11591/ijeecs.v18.i3.pp1236-1243
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079180911&doi=10.11591%2fijeecs.v18.i3.pp1236-1243&partnerID=40&md5=bd93aabda7096718735ba797940393ba
A hydroponics plant can grow healthily with sufficient nutrient, temperature, light, humidity as well as pH level that is indeed vital in ensuring the plants will absorb maximum nutrient elements required. This paper presents automated monitoring and controlling pH levels for the hydroponic cultivation technique. In this study, automated monitoring and controlling of pH levels are developed specifically for the hydroponic cultivation technique. There are three main methods that involved in the development of the system namely hardware, programming and functionality test. Firstly, users need to set the maximum and minimum pH levels as required by the plant. Then, the pH sensor will monitor the real-time pH level of the water. A syringe pump that contains a pH up solution (alkaline) and a pH down solution (acid) will drip the solutions to neutralize the water content if the water pH level is not within the stated ranges as set by the user. Results showed that the automated monitoring and controlling pH levels were successfully developed and functionality was tested and confirmed as desired. The syringe pumps responded perfectly upon changes of the water pH value based on the validation done that showed 100% accuracy of the syringe pump responds. Copyright © 2020 Institute of Advanced Engineering and Science. All rights reserved.
Institute of Advanced Engineering and Science
25024752
English
Article
All Open Access; Gold Open Access
author Saaid M.F.; Yassin A.I.M.; Tahir N.M.
spellingShingle Saaid M.F.; Yassin A.I.M.; Tahir N.M.
Automated monitoring and controlling pH levels for hydroponics cultivation technique
author_facet Saaid M.F.; Yassin A.I.M.; Tahir N.M.
author_sort Saaid M.F.; Yassin A.I.M.; Tahir N.M.
title Automated monitoring and controlling pH levels for hydroponics cultivation technique
title_short Automated monitoring and controlling pH levels for hydroponics cultivation technique
title_full Automated monitoring and controlling pH levels for hydroponics cultivation technique
title_fullStr Automated monitoring and controlling pH levels for hydroponics cultivation technique
title_full_unstemmed Automated monitoring and controlling pH levels for hydroponics cultivation technique
title_sort Automated monitoring and controlling pH levels for hydroponics cultivation technique
publishDate 2020
container_title Indonesian Journal of Electrical Engineering and Computer Science
container_volume 18
container_issue 3
doi_str_mv 10.11591/ijeecs.v18.i3.pp1236-1243
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079180911&doi=10.11591%2fijeecs.v18.i3.pp1236-1243&partnerID=40&md5=bd93aabda7096718735ba797940393ba
description A hydroponics plant can grow healthily with sufficient nutrient, temperature, light, humidity as well as pH level that is indeed vital in ensuring the plants will absorb maximum nutrient elements required. This paper presents automated monitoring and controlling pH levels for the hydroponic cultivation technique. In this study, automated monitoring and controlling of pH levels are developed specifically for the hydroponic cultivation technique. There are three main methods that involved in the development of the system namely hardware, programming and functionality test. Firstly, users need to set the maximum and minimum pH levels as required by the plant. Then, the pH sensor will monitor the real-time pH level of the water. A syringe pump that contains a pH up solution (alkaline) and a pH down solution (acid) will drip the solutions to neutralize the water content if the water pH level is not within the stated ranges as set by the user. Results showed that the automated monitoring and controlling pH levels were successfully developed and functionality was tested and confirmed as desired. The syringe pumps responded perfectly upon changes of the water pH value based on the validation done that showed 100% accuracy of the syringe pump responds. Copyright © 2020 Institute of Advanced Engineering and Science. All rights reserved.
publisher Institute of Advanced Engineering and Science
issn 25024752
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677899177918464