An Optimized Honey Dehydration System with Drying Air Temperature and Relative Humidity Control

This paper presents a system that can reduce the water percentage of stingless bee honey with a microcontroller to control the drying process employing temperature, drying air speed, relative humidity, and optimized honey exposure surface. The main objective is to reduce water content in stingless b...

Full description

Bibliographic Details
Published in:2019 IEEE International Conference on Automatic Control and Intelligent Systems, I2CACIS 2019 - Proceedings
Main Author: Abid A.; Yunus M.A.M.; Sahlan S.; Ramli M.M.; Amin M.R.A.; Lotpi Z.F.M.; Anuar N.H.K.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2019
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072917168&doi=10.1109%2fI2CACIS.2019.8825033&partnerID=40&md5=ce50d81c4ffd1e4158a7a1f5159c8964
id 2-s2.0-85072917168
spelling 2-s2.0-85072917168
Abid A.; Yunus M.A.M.; Sahlan S.; Ramli M.M.; Amin M.R.A.; Lotpi Z.F.M.; Anuar N.H.K.
An Optimized Honey Dehydration System with Drying Air Temperature and Relative Humidity Control
2019
2019 IEEE International Conference on Automatic Control and Intelligent Systems, I2CACIS 2019 - Proceedings


10.1109/I2CACIS.2019.8825033
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072917168&doi=10.1109%2fI2CACIS.2019.8825033&partnerID=40&md5=ce50d81c4ffd1e4158a7a1f5159c8964
This paper presents a system that can reduce the water percentage of stingless bee honey with a microcontroller to control the drying process employing temperature, drying air speed, relative humidity, and optimized honey exposure surface. The main objective is to reduce water content in stingless bee honey at 22 % in order to prevent rapid fermentation and delay crystallization. This water reduction process is important to preserve the quality and extend the storage period of honey. The system comprises of a programmed microcontroller, a main insulated container, a 12 V and 400 ml/min peristaltic pump, a 2800 Watt hair dryer, a temperature and relative humidity sensor, an exhaust fan, a relative humidity control system made of a smaller insulated container and a thermoelectric Peltier cooler module, a perforated stainless steel tray, and a switching circuit/a controller circuit. In this system, the temperature control was achieved using an on-off controller. The results showed that stingless bee honey samples between 2 and 8 kg was processed, where the percentage of water dropped from between 29-28 % to 21.2% with dehydration rate of 53.39 g/h. © 2019 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Abid A.; Yunus M.A.M.; Sahlan S.; Ramli M.M.; Amin M.R.A.; Lotpi Z.F.M.; Anuar N.H.K.
spellingShingle Abid A.; Yunus M.A.M.; Sahlan S.; Ramli M.M.; Amin M.R.A.; Lotpi Z.F.M.; Anuar N.H.K.
An Optimized Honey Dehydration System with Drying Air Temperature and Relative Humidity Control
author_facet Abid A.; Yunus M.A.M.; Sahlan S.; Ramli M.M.; Amin M.R.A.; Lotpi Z.F.M.; Anuar N.H.K.
author_sort Abid A.; Yunus M.A.M.; Sahlan S.; Ramli M.M.; Amin M.R.A.; Lotpi Z.F.M.; Anuar N.H.K.
title An Optimized Honey Dehydration System with Drying Air Temperature and Relative Humidity Control
title_short An Optimized Honey Dehydration System with Drying Air Temperature and Relative Humidity Control
title_full An Optimized Honey Dehydration System with Drying Air Temperature and Relative Humidity Control
title_fullStr An Optimized Honey Dehydration System with Drying Air Temperature and Relative Humidity Control
title_full_unstemmed An Optimized Honey Dehydration System with Drying Air Temperature and Relative Humidity Control
title_sort An Optimized Honey Dehydration System with Drying Air Temperature and Relative Humidity Control
publishDate 2019
container_title 2019 IEEE International Conference on Automatic Control and Intelligent Systems, I2CACIS 2019 - Proceedings
container_volume
container_issue
doi_str_mv 10.1109/I2CACIS.2019.8825033
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072917168&doi=10.1109%2fI2CACIS.2019.8825033&partnerID=40&md5=ce50d81c4ffd1e4158a7a1f5159c8964
description This paper presents a system that can reduce the water percentage of stingless bee honey with a microcontroller to control the drying process employing temperature, drying air speed, relative humidity, and optimized honey exposure surface. The main objective is to reduce water content in stingless bee honey at 22 % in order to prevent rapid fermentation and delay crystallization. This water reduction process is important to preserve the quality and extend the storage period of honey. The system comprises of a programmed microcontroller, a main insulated container, a 12 V and 400 ml/min peristaltic pump, a 2800 Watt hair dryer, a temperature and relative humidity sensor, an exhaust fan, a relative humidity control system made of a smaller insulated container and a thermoelectric Peltier cooler module, a perforated stainless steel tray, and a switching circuit/a controller circuit. In this system, the temperature control was achieved using an on-off controller. The results showed that stingless bee honey samples between 2 and 8 kg was processed, where the percentage of water dropped from between 29-28 % to 21.2% with dehydration rate of 53.39 g/h. © 2019 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677687226105856