Multifiring endoclip conceptual design using cad approach

The endoclip design that will be done is by designing cartridge components that have several clips. In essence, endoclip is a mechanical device in the world of health, especially for endoscopic activities, which are also used for the process of hemostasis and also non-hemostatic applications. This s...

Full description

Bibliographic Details
Published in:IOP Conference Series: Materials Science and Engineering
Main Author: Siregar I.; Adenan M.S.; Ariffin A.C.; Saedon J.B.; Asro H.
Format: Conference paper
Language:English
Published: Institute of Physics Publishing 2019
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85069045383&doi=10.1088%2f1757-899X%2f505%2f1%2f012053&partnerID=40&md5=b668afcc75bc8f9b7b062e2adb752e72
id 2-s2.0-85069045383
spelling 2-s2.0-85069045383
Siregar I.; Adenan M.S.; Ariffin A.C.; Saedon J.B.; Asro H.
Multifiring endoclip conceptual design using cad approach
2019
IOP Conference Series: Materials Science and Engineering
505
1
10.1088/1757-899X/505/1/012053
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85069045383&doi=10.1088%2f1757-899X%2f505%2f1%2f012053&partnerID=40&md5=b668afcc75bc8f9b7b062e2adb752e72
The endoclip design that will be done is by designing cartridge components that have several clips. In essence, endoclip is a mechanical device in the world of health, especially for endoscopic activities, which are also used for the process of hemostasis and also non-hemostatic applications. This study describes the relationship between end-time end-endoscopic problems during gastrointestinal standards. Currently, market-available endoclips only focus on single-firing, where the process is carried out one by one. The use of Endoclip at this time is very difficult because of the repetition of the clip loading process to the applicator. Therefore, the purpose of this research is to design cartridges which consist of several clips for endoclip and allow for mechanical movements. The method of selecting the appropriate and important part of the tip which is the most important way to solve the problem and the design and process of the simulation is done using CATIA V5 software. The aim of this study was achieved by increasing the critical part of the catheter by replacing it with a cartridge design that contained several clips that allowed the clipping process to be multi-firing, not one-shot and also by simulating the mechanism. © Published under licence by IOP Publishing Ltd.
Institute of Physics Publishing
17578981
English
Conference paper
All Open Access; Gold Open Access
author Siregar I.; Adenan M.S.; Ariffin A.C.; Saedon J.B.; Asro H.
spellingShingle Siregar I.; Adenan M.S.; Ariffin A.C.; Saedon J.B.; Asro H.
Multifiring endoclip conceptual design using cad approach
author_facet Siregar I.; Adenan M.S.; Ariffin A.C.; Saedon J.B.; Asro H.
author_sort Siregar I.; Adenan M.S.; Ariffin A.C.; Saedon J.B.; Asro H.
title Multifiring endoclip conceptual design using cad approach
title_short Multifiring endoclip conceptual design using cad approach
title_full Multifiring endoclip conceptual design using cad approach
title_fullStr Multifiring endoclip conceptual design using cad approach
title_full_unstemmed Multifiring endoclip conceptual design using cad approach
title_sort Multifiring endoclip conceptual design using cad approach
publishDate 2019
container_title IOP Conference Series: Materials Science and Engineering
container_volume 505
container_issue 1
doi_str_mv 10.1088/1757-899X/505/1/012053
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85069045383&doi=10.1088%2f1757-899X%2f505%2f1%2f012053&partnerID=40&md5=b668afcc75bc8f9b7b062e2adb752e72
description The endoclip design that will be done is by designing cartridge components that have several clips. In essence, endoclip is a mechanical device in the world of health, especially for endoscopic activities, which are also used for the process of hemostasis and also non-hemostatic applications. This study describes the relationship between end-time end-endoscopic problems during gastrointestinal standards. Currently, market-available endoclips only focus on single-firing, where the process is carried out one by one. The use of Endoclip at this time is very difficult because of the repetition of the clip loading process to the applicator. Therefore, the purpose of this research is to design cartridges which consist of several clips for endoclip and allow for mechanical movements. The method of selecting the appropriate and important part of the tip which is the most important way to solve the problem and the design and process of the simulation is done using CATIA V5 software. The aim of this study was achieved by increasing the critical part of the catheter by replacing it with a cartridge design that contained several clips that allowed the clipping process to be multi-firing, not one-shot and also by simulating the mechanism. © Published under licence by IOP Publishing Ltd.
publisher Institute of Physics Publishing
issn 17578981
language English
format Conference paper
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677901906313216