Performance comparison of distributed generation installation arrangement in transmission system for loss control

Placing Distributed generation (DG) into a power network should be planned wisely. In this paper, the comparison of having different installation arrangement of real-power DGs in transmission system for loss control is presented. Immune-brainstorm-evolutionary programme (IBSEP) was chosen as the opt...

Full description

Bibliographic Details
Published in:Bulletin of Electrical Engineering and Informatics
Main Author: Shaaya S.A.; Musirin I.; Sulaiman S.I.; Mansor M.H.; Syed Mustaffa S.A.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2019
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85065236446&doi=10.11591%2feei.v8i1.1443&partnerID=40&md5=c2d451ca55a5a0849c2155965399d1ce
id 2-s2.0-85065236446
spelling 2-s2.0-85065236446
Shaaya S.A.; Musirin I.; Sulaiman S.I.; Mansor M.H.; Syed Mustaffa S.A.
Performance comparison of distributed generation installation arrangement in transmission system for loss control
2019
Bulletin of Electrical Engineering and Informatics
8
1
10.11591/eei.v8i1.1443
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85065236446&doi=10.11591%2feei.v8i1.1443&partnerID=40&md5=c2d451ca55a5a0849c2155965399d1ce
Placing Distributed generation (DG) into a power network should be planned wisely. In this paper, the comparison of having different installation arrangement of real-power DGs in transmission system for loss control is presented. Immune-brainstorm-evolutionary programme (IBSEP) was chosen as the optimization technique. It is found that optimizing fixed-size DGs locations gives the highest loss reduction percentage. Apart from that, scattered small-sized DGs throughout a network minimizes transmission loss more than allocating one biger-sized DG at a location. © 2019 Institute of Advanced Engineering and Science.
Institute of Advanced Engineering and Science
20893191
English
Article
All Open Access; Gold Open Access
author Shaaya S.A.; Musirin I.; Sulaiman S.I.; Mansor M.H.; Syed Mustaffa S.A.
spellingShingle Shaaya S.A.; Musirin I.; Sulaiman S.I.; Mansor M.H.; Syed Mustaffa S.A.
Performance comparison of distributed generation installation arrangement in transmission system for loss control
author_facet Shaaya S.A.; Musirin I.; Sulaiman S.I.; Mansor M.H.; Syed Mustaffa S.A.
author_sort Shaaya S.A.; Musirin I.; Sulaiman S.I.; Mansor M.H.; Syed Mustaffa S.A.
title Performance comparison of distributed generation installation arrangement in transmission system for loss control
title_short Performance comparison of distributed generation installation arrangement in transmission system for loss control
title_full Performance comparison of distributed generation installation arrangement in transmission system for loss control
title_fullStr Performance comparison of distributed generation installation arrangement in transmission system for loss control
title_full_unstemmed Performance comparison of distributed generation installation arrangement in transmission system for loss control
title_sort Performance comparison of distributed generation installation arrangement in transmission system for loss control
publishDate 2019
container_title Bulletin of Electrical Engineering and Informatics
container_volume 8
container_issue 1
doi_str_mv 10.11591/eei.v8i1.1443
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85065236446&doi=10.11591%2feei.v8i1.1443&partnerID=40&md5=c2d451ca55a5a0849c2155965399d1ce
description Placing Distributed generation (DG) into a power network should be planned wisely. In this paper, the comparison of having different installation arrangement of real-power DGs in transmission system for loss control is presented. Immune-brainstorm-evolutionary programme (IBSEP) was chosen as the optimization technique. It is found that optimizing fixed-size DGs locations gives the highest loss reduction percentage. Apart from that, scattered small-sized DGs throughout a network minimizes transmission loss more than allocating one biger-sized DG at a location. © 2019 Institute of Advanced Engineering and Science.
publisher Institute of Advanced Engineering and Science
issn 20893191
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677904632610816