Effect of column size on the seismic capacity of elevated reinforced concrete water tank
Elevated reinforced concrete water tanks are one of the most essential structure to major cities and also in rural areas before, during and after a disaster such earthquake. It is important to prevent elevated reinforced concrete water tank from collapse so the water supply can be maintained. One of...
Published in: | IOP Conference Series: Earth and Environmental Science |
---|---|
Main Author: | |
Format: | Conference paper |
Language: | English |
Published: |
Institute of Physics Publishing
2019
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85063484285&doi=10.1088%2f1755-1315%2f244%2f1%2f012010&partnerID=40&md5=569bc176f42f084c340529e191ca3603 |
id |
2-s2.0-85063484285 |
---|---|
spelling |
2-s2.0-85063484285 Adiyanto M.I.; Damit A.A.A.; Yaakup S.N.; Mustapha S.A.H.S.; Chin S.C. Effect of column size on the seismic capacity of elevated reinforced concrete water tank 2019 IOP Conference Series: Earth and Environmental Science 244 1 10.1088/1755-1315/244/1/012010 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85063484285&doi=10.1088%2f1755-1315%2f244%2f1%2f012010&partnerID=40&md5=569bc176f42f084c340529e191ca3603 Elevated reinforced concrete water tanks are one of the most essential structure to major cities and also in rural areas before, during and after a disaster such earthquake. It is important to prevent elevated reinforced concrete water tank from collapse so the water supply can be maintained. One of the methods used to evaluate the seismic capacity of elevated reinforced concrete water tank is the pushover analysis. Pushover analysis is based on the assumption that structure oscillate predominantly in the first mode or in the lower modes of vibration during a seismic event. The objective of this project is to study the effect of column size on the seismic capacity of elevated reinforced concrete water tank. A total number of 10 models of elevated reinforced concrete water tanks consist of 4 storey and 7 storey has been used for this project. All models have been designed repeatedly to 5 different size of column for each storey, where the beam size is fixed for each model. All models have been designed based on BS8110 to represent the existing elevated reinforced concrete water tanks. Then the pushover analysis has been conducted on all models to study the seismic capacity of elevated reinforced concrete water tank. An adequate information on seismic demands imposed on the structural system and its components by the designed ground motion will be provided from the pushover analysis. Based on the pushover analysis conducted in this study, the elevated RC water tank with larger size of column tend to have higher value of force at yield limit state and ultimate limit state. © 2019 Published under licence by IOP Publishing Ltd. Institute of Physics Publishing 17551307 English Conference paper All Open Access; Gold Open Access |
author |
Adiyanto M.I.; Damit A.A.A.; Yaakup S.N.; Mustapha S.A.H.S.; Chin S.C. |
spellingShingle |
Adiyanto M.I.; Damit A.A.A.; Yaakup S.N.; Mustapha S.A.H.S.; Chin S.C. Effect of column size on the seismic capacity of elevated reinforced concrete water tank |
author_facet |
Adiyanto M.I.; Damit A.A.A.; Yaakup S.N.; Mustapha S.A.H.S.; Chin S.C. |
author_sort |
Adiyanto M.I.; Damit A.A.A.; Yaakup S.N.; Mustapha S.A.H.S.; Chin S.C. |
title |
Effect of column size on the seismic capacity of elevated reinforced concrete water tank |
title_short |
Effect of column size on the seismic capacity of elevated reinforced concrete water tank |
title_full |
Effect of column size on the seismic capacity of elevated reinforced concrete water tank |
title_fullStr |
Effect of column size on the seismic capacity of elevated reinforced concrete water tank |
title_full_unstemmed |
Effect of column size on the seismic capacity of elevated reinforced concrete water tank |
title_sort |
Effect of column size on the seismic capacity of elevated reinforced concrete water tank |
publishDate |
2019 |
container_title |
IOP Conference Series: Earth and Environmental Science |
container_volume |
244 |
container_issue |
1 |
doi_str_mv |
10.1088/1755-1315/244/1/012010 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85063484285&doi=10.1088%2f1755-1315%2f244%2f1%2f012010&partnerID=40&md5=569bc176f42f084c340529e191ca3603 |
description |
Elevated reinforced concrete water tanks are one of the most essential structure to major cities and also in rural areas before, during and after a disaster such earthquake. It is important to prevent elevated reinforced concrete water tank from collapse so the water supply can be maintained. One of the methods used to evaluate the seismic capacity of elevated reinforced concrete water tank is the pushover analysis. Pushover analysis is based on the assumption that structure oscillate predominantly in the first mode or in the lower modes of vibration during a seismic event. The objective of this project is to study the effect of column size on the seismic capacity of elevated reinforced concrete water tank. A total number of 10 models of elevated reinforced concrete water tanks consist of 4 storey and 7 storey has been used for this project. All models have been designed repeatedly to 5 different size of column for each storey, where the beam size is fixed for each model. All models have been designed based on BS8110 to represent the existing elevated reinforced concrete water tanks. Then the pushover analysis has been conducted on all models to study the seismic capacity of elevated reinforced concrete water tank. An adequate information on seismic demands imposed on the structural system and its components by the designed ground motion will be provided from the pushover analysis. Based on the pushover analysis conducted in this study, the elevated RC water tank with larger size of column tend to have higher value of force at yield limit state and ultimate limit state. © 2019 Published under licence by IOP Publishing Ltd. |
publisher |
Institute of Physics Publishing |
issn |
17551307 |
language |
English |
format |
Conference paper |
accesstype |
All Open Access; Gold Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1809677904273997824 |