Investigation of knee flexion angle influences on intra-body communication’s (IBC) signal attenuation

Galvanic coupling method is one of the methods introduced in intra-body communication (IBC). IBC uses human body to as the communication medium for data transmission. In this paper, the investigation focuses on signal attenuation performance across knee joint using the galvanic coupling analysis. Th...

Full description

Bibliographic Details
Published in:Indonesian Journal of Electrical Engineering and Computer Science
Main Author: Ibrahim I.W.; Aruwa M.M.M.; Razak A.H.A.; Ahmad A.; Khir R.N.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2018
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85047797310&doi=10.11591%2fijeecs.v9.i2.pp424-430&partnerID=40&md5=6727868032e1df81952b48e9401cb75a
id 2-s2.0-85047797310
spelling 2-s2.0-85047797310
Ibrahim I.W.; Aruwa M.M.M.; Razak A.H.A.; Ahmad A.; Khir R.N.
Investigation of knee flexion angle influences on intra-body communication’s (IBC) signal attenuation
2018
Indonesian Journal of Electrical Engineering and Computer Science
9
2
10.11591/ijeecs.v9.i2.pp424-430
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85047797310&doi=10.11591%2fijeecs.v9.i2.pp424-430&partnerID=40&md5=6727868032e1df81952b48e9401cb75a
Galvanic coupling method is one of the methods introduced in intra-body communication (IBC). IBC uses human body to as the communication medium for data transmission. In this paper, the investigation focuses on signal attenuation performance across knee joint using the galvanic coupling analysis. The signal attenuation was determined by implementing the galvanic coupling analysis at specific knee flexion angle. The galvanic analysis initiated by deciding the operating frequency in between 40 to 60 MHz in order to analyze the signal attenuation between the knee flexion angles. This paper found that the lowest signal attenuation at the operating frequency was 47.25dB, while the highest one was 52.63dB where the knee flexion angle is 0o and 155o respectively. It was concluded that the signal attenuation decrease with the increasing of knee joint existence at the specific flexion angle. However, a wider experiment must be conducted for various data that will correspond to signal attenuation for various influenced human data characteristics. © 2018 Institute of Advanced Engineering and Science. All rights reserved.
Institute of Advanced Engineering and Science
25024752
English
Article
All Open Access; Green Open Access
author Ibrahim I.W.; Aruwa M.M.M.; Razak A.H.A.; Ahmad A.; Khir R.N.
spellingShingle Ibrahim I.W.; Aruwa M.M.M.; Razak A.H.A.; Ahmad A.; Khir R.N.
Investigation of knee flexion angle influences on intra-body communication’s (IBC) signal attenuation
author_facet Ibrahim I.W.; Aruwa M.M.M.; Razak A.H.A.; Ahmad A.; Khir R.N.
author_sort Ibrahim I.W.; Aruwa M.M.M.; Razak A.H.A.; Ahmad A.; Khir R.N.
title Investigation of knee flexion angle influences on intra-body communication’s (IBC) signal attenuation
title_short Investigation of knee flexion angle influences on intra-body communication’s (IBC) signal attenuation
title_full Investigation of knee flexion angle influences on intra-body communication’s (IBC) signal attenuation
title_fullStr Investigation of knee flexion angle influences on intra-body communication’s (IBC) signal attenuation
title_full_unstemmed Investigation of knee flexion angle influences on intra-body communication’s (IBC) signal attenuation
title_sort Investigation of knee flexion angle influences on intra-body communication’s (IBC) signal attenuation
publishDate 2018
container_title Indonesian Journal of Electrical Engineering and Computer Science
container_volume 9
container_issue 2
doi_str_mv 10.11591/ijeecs.v9.i2.pp424-430
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85047797310&doi=10.11591%2fijeecs.v9.i2.pp424-430&partnerID=40&md5=6727868032e1df81952b48e9401cb75a
description Galvanic coupling method is one of the methods introduced in intra-body communication (IBC). IBC uses human body to as the communication medium for data transmission. In this paper, the investigation focuses on signal attenuation performance across knee joint using the galvanic coupling analysis. The signal attenuation was determined by implementing the galvanic coupling analysis at specific knee flexion angle. The galvanic analysis initiated by deciding the operating frequency in between 40 to 60 MHz in order to analyze the signal attenuation between the knee flexion angles. This paper found that the lowest signal attenuation at the operating frequency was 47.25dB, while the highest one was 52.63dB where the knee flexion angle is 0o and 155o respectively. It was concluded that the signal attenuation decrease with the increasing of knee joint existence at the specific flexion angle. However, a wider experiment must be conducted for various data that will correspond to signal attenuation for various influenced human data characteristics. © 2018 Institute of Advanced Engineering and Science. All rights reserved.
publisher Institute of Advanced Engineering and Science
issn 25024752
language English
format Article
accesstype All Open Access; Green Open Access
record_format scopus
collection Scopus
_version_ 1809677907190087680