Evaluation of fluoride concentration in water filter system for households

Drinking water that has good quality is important to sustain human life. If the sources of the drinking water have been contaminated by pollutants, it can give harmful effects to human. Besides of pollutants, good quality of drinking water should have optimum concentration of minerals and one of nec...

Full description

Bibliographic Details
Published in:International Journal of Integrated Engineering
Main Author: Bahari M.; Kamil N.A.F.M.; Akbar N.A.; Mizad M.
Format: Article
Language:English
Published: Penerbit UTHM 2018
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85046955124&doi=10.30880%2fijie.2018.10.02.023&partnerID=40&md5=f5ca251c6de54d14d5a15eca836b02a0
id 2-s2.0-85046955124
spelling 2-s2.0-85046955124
Bahari M.; Kamil N.A.F.M.; Akbar N.A.; Mizad M.
Evaluation of fluoride concentration in water filter system for households
2018
International Journal of Integrated Engineering
10
2
10.30880/ijie.2018.10.02.023
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85046955124&doi=10.30880%2fijie.2018.10.02.023&partnerID=40&md5=f5ca251c6de54d14d5a15eca836b02a0
Drinking water that has good quality is important to sustain human life. If the sources of the drinking water have been contaminated by pollutants, it can give harmful effects to human. Besides of pollutants, good quality of drinking water should have optimum concentration of minerals and one of necessary minerals is fluoride. However, fluoride concentration is less emphasized in factor of purchasing the water filter system. In addition, Malaysians are not aware of the importance of optimum fluoride concentration in their drinking. Water filter system is installed to obtain the good quality of drinking water and needs the maintenance services to ensure the quality of drinking water accomplishes a constant protection. However, the performance of maintenance service is never being measured. Therefore, this study was conducted to measure the fluoride concentration in drinking water for household and evaluate the performance of maintenance service in water filter system. Two residential areas in Johor were involved in data collection. Fluoride concentrations at influent of water filter system were in range of 2.41 mg/L to 3.84 mg/L which were above the permissible limit except for USEPA standard. Concentrations at effluent for before maintenance service were reduced, in range of 0.89 mg/L to 1.28 mg/L, and thus water filter system is necessary to install in Malaysian household. However, very low concentrations were detected after maintenance service, in range of 0.08 mg/L and 0.12 mg/L, and thus the maintenance service needs to be revised to obtain the optimum fluoride concentration. © Penerbit UTHM.
Penerbit UTHM
2229838X
English
Article
All Open Access; Bronze Open Access
author Bahari M.; Kamil N.A.F.M.; Akbar N.A.; Mizad M.
spellingShingle Bahari M.; Kamil N.A.F.M.; Akbar N.A.; Mizad M.
Evaluation of fluoride concentration in water filter system for households
author_facet Bahari M.; Kamil N.A.F.M.; Akbar N.A.; Mizad M.
author_sort Bahari M.; Kamil N.A.F.M.; Akbar N.A.; Mizad M.
title Evaluation of fluoride concentration in water filter system for households
title_short Evaluation of fluoride concentration in water filter system for households
title_full Evaluation of fluoride concentration in water filter system for households
title_fullStr Evaluation of fluoride concentration in water filter system for households
title_full_unstemmed Evaluation of fluoride concentration in water filter system for households
title_sort Evaluation of fluoride concentration in water filter system for households
publishDate 2018
container_title International Journal of Integrated Engineering
container_volume 10
container_issue 2
doi_str_mv 10.30880/ijie.2018.10.02.023
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85046955124&doi=10.30880%2fijie.2018.10.02.023&partnerID=40&md5=f5ca251c6de54d14d5a15eca836b02a0
description Drinking water that has good quality is important to sustain human life. If the sources of the drinking water have been contaminated by pollutants, it can give harmful effects to human. Besides of pollutants, good quality of drinking water should have optimum concentration of minerals and one of necessary minerals is fluoride. However, fluoride concentration is less emphasized in factor of purchasing the water filter system. In addition, Malaysians are not aware of the importance of optimum fluoride concentration in their drinking. Water filter system is installed to obtain the good quality of drinking water and needs the maintenance services to ensure the quality of drinking water accomplishes a constant protection. However, the performance of maintenance service is never being measured. Therefore, this study was conducted to measure the fluoride concentration in drinking water for household and evaluate the performance of maintenance service in water filter system. Two residential areas in Johor were involved in data collection. Fluoride concentrations at influent of water filter system were in range of 2.41 mg/L to 3.84 mg/L which were above the permissible limit except for USEPA standard. Concentrations at effluent for before maintenance service were reduced, in range of 0.89 mg/L to 1.28 mg/L, and thus water filter system is necessary to install in Malaysian household. However, very low concentrations were detected after maintenance service, in range of 0.08 mg/L and 0.12 mg/L, and thus the maintenance service needs to be revised to obtain the optimum fluoride concentration. © Penerbit UTHM.
publisher Penerbit UTHM
issn 2229838X
language English
format Article
accesstype All Open Access; Bronze Open Access
record_format scopus
collection Scopus
_version_ 1818940561709596672