Evaluation of dose sensitivity response via optical characteristics for cresol red-dyed polyhydroxyethylmethacrylate gel (PHEMAG); [Penilaian respons kepekaan dos melalui ciri optikal bagi kresol merah-dicelup polihidrosietilmetakrilik gel (PHEMAG)]

A new polymer gel blended with the acid base indicator of cresol red were prepared consisted of 4%, 5% and 6% of monomer (2-Hydroxyethyl Methacrylate; HEMA) in order to characterize the radiation induced changes known as cresol red Polyhydroxyethylmethacrylate Gel (PHEMAG). Cresol red-dyed PHEMAG we...

Full description

Bibliographic Details
Published in:Malaysian Journal of Analytical Sciences
Main Author: Nur Sha’adah Z.; Lothfy F.A.; Rafaie H.A.; Mazlan M.; Mustafa I.S.; Abdul Rahman A.
Format: Article
Language:English
Published: Malaysian Society of Analytical Sciences 2018
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85046763533&doi=10.17576%2fmjas-2018-2202-16&partnerID=40&md5=28d00617bdfed66fe9e0ddd30f38e72a
id 2-s2.0-85046763533
spelling 2-s2.0-85046763533
Nur Sha’adah Z.; Lothfy F.A.; Rafaie H.A.; Mazlan M.; Mustafa I.S.; Abdul Rahman A.
Evaluation of dose sensitivity response via optical characteristics for cresol red-dyed polyhydroxyethylmethacrylate gel (PHEMAG); [Penilaian respons kepekaan dos melalui ciri optikal bagi kresol merah-dicelup polihidrosietilmetakrilik gel (PHEMAG)]
2018
Malaysian Journal of Analytical Sciences
22
2
10.17576/mjas-2018-2202-16
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85046763533&doi=10.17576%2fmjas-2018-2202-16&partnerID=40&md5=28d00617bdfed66fe9e0ddd30f38e72a
A new polymer gel blended with the acid base indicator of cresol red were prepared consisted of 4%, 5% and 6% of monomer (2-Hydroxyethyl Methacrylate; HEMA) in order to characterize the radiation induced changes known as cresol red Polyhydroxyethylmethacrylate Gel (PHEMAG). Cresol red-dyed PHEMAG were prepared consisted of gelatin, deionized water, HEMA, cresol red sodium salt stock solution and ascorbic acid. The polymerization Cresol red-PHEMAG was studied with 6 MV photon beam rates 300 Gy/min which received doses up to 40 Gy for the reveletion sensitivity as a function of absorbed dose based on the physical properties by using UV-Vis spectroscopy. It is indicated that 4% of HEMA exhibited a greater sensitivity of the polymer gel dosimeter based on a mathematical model of the fitting equation of the dose response curve. The value of Do (sensitivity parameter) for 4% of HEMA is the lowest about 42.373 Gy. The lower value of Do would cause the higher radiosensitive of the matter which was actively reacted at the time of exposure. © 2018, Malaysian Society of Analytical Sciences. All rights reserved.
Malaysian Society of Analytical Sciences
13942506
English
Article
All Open Access; Gold Open Access
author Nur Sha’adah Z.; Lothfy F.A.; Rafaie H.A.; Mazlan M.; Mustafa I.S.; Abdul Rahman A.
spellingShingle Nur Sha’adah Z.; Lothfy F.A.; Rafaie H.A.; Mazlan M.; Mustafa I.S.; Abdul Rahman A.
Evaluation of dose sensitivity response via optical characteristics for cresol red-dyed polyhydroxyethylmethacrylate gel (PHEMAG); [Penilaian respons kepekaan dos melalui ciri optikal bagi kresol merah-dicelup polihidrosietilmetakrilik gel (PHEMAG)]
author_facet Nur Sha’adah Z.; Lothfy F.A.; Rafaie H.A.; Mazlan M.; Mustafa I.S.; Abdul Rahman A.
author_sort Nur Sha’adah Z.; Lothfy F.A.; Rafaie H.A.; Mazlan M.; Mustafa I.S.; Abdul Rahman A.
title Evaluation of dose sensitivity response via optical characteristics for cresol red-dyed polyhydroxyethylmethacrylate gel (PHEMAG); [Penilaian respons kepekaan dos melalui ciri optikal bagi kresol merah-dicelup polihidrosietilmetakrilik gel (PHEMAG)]
title_short Evaluation of dose sensitivity response via optical characteristics for cresol red-dyed polyhydroxyethylmethacrylate gel (PHEMAG); [Penilaian respons kepekaan dos melalui ciri optikal bagi kresol merah-dicelup polihidrosietilmetakrilik gel (PHEMAG)]
title_full Evaluation of dose sensitivity response via optical characteristics for cresol red-dyed polyhydroxyethylmethacrylate gel (PHEMAG); [Penilaian respons kepekaan dos melalui ciri optikal bagi kresol merah-dicelup polihidrosietilmetakrilik gel (PHEMAG)]
title_fullStr Evaluation of dose sensitivity response via optical characteristics for cresol red-dyed polyhydroxyethylmethacrylate gel (PHEMAG); [Penilaian respons kepekaan dos melalui ciri optikal bagi kresol merah-dicelup polihidrosietilmetakrilik gel (PHEMAG)]
title_full_unstemmed Evaluation of dose sensitivity response via optical characteristics for cresol red-dyed polyhydroxyethylmethacrylate gel (PHEMAG); [Penilaian respons kepekaan dos melalui ciri optikal bagi kresol merah-dicelup polihidrosietilmetakrilik gel (PHEMAG)]
title_sort Evaluation of dose sensitivity response via optical characteristics for cresol red-dyed polyhydroxyethylmethacrylate gel (PHEMAG); [Penilaian respons kepekaan dos melalui ciri optikal bagi kresol merah-dicelup polihidrosietilmetakrilik gel (PHEMAG)]
publishDate 2018
container_title Malaysian Journal of Analytical Sciences
container_volume 22
container_issue 2
doi_str_mv 10.17576/mjas-2018-2202-16
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85046763533&doi=10.17576%2fmjas-2018-2202-16&partnerID=40&md5=28d00617bdfed66fe9e0ddd30f38e72a
description A new polymer gel blended with the acid base indicator of cresol red were prepared consisted of 4%, 5% and 6% of monomer (2-Hydroxyethyl Methacrylate; HEMA) in order to characterize the radiation induced changes known as cresol red Polyhydroxyethylmethacrylate Gel (PHEMAG). Cresol red-dyed PHEMAG were prepared consisted of gelatin, deionized water, HEMA, cresol red sodium salt stock solution and ascorbic acid. The polymerization Cresol red-PHEMAG was studied with 6 MV photon beam rates 300 Gy/min which received doses up to 40 Gy for the reveletion sensitivity as a function of absorbed dose based on the physical properties by using UV-Vis spectroscopy. It is indicated that 4% of HEMA exhibited a greater sensitivity of the polymer gel dosimeter based on a mathematical model of the fitting equation of the dose response curve. The value of Do (sensitivity parameter) for 4% of HEMA is the lowest about 42.373 Gy. The lower value of Do would cause the higher radiosensitive of the matter which was actively reacted at the time of exposure. © 2018, Malaysian Society of Analytical Sciences. All rights reserved.
publisher Malaysian Society of Analytical Sciences
issn 13942506
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677906829377536