Stress and damage formation analysis in hip arthroplasties using CT-based finite element method

Femoral neck fractures and prosthesis loosening are several biomechanical concerns in promoting the long term stability of hip arthroplasties. External high impact loading due to sideway falls may contribute to the risk of femoral fractures and joint failures. The purpose of this study is to investi...

Full description

Bibliographic Details
Published in:Journal of Engineering and Applied Sciences
Main Author: Abdullah A.H.; Todo M.; Nakashima Y.
Format: Article
Language:English
Published: Medwell Journals 2017
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85045303479&doi=10.3923%2fjeasci.2017.2715.2719&partnerID=40&md5=05fc20525c2833cfddf31fb9ac05df6a
id 2-s2.0-85045303479
spelling 2-s2.0-85045303479
Abdullah A.H.; Todo M.; Nakashima Y.
Stress and damage formation analysis in hip arthroplasties using CT-based finite element method
2017
Journal of Engineering and Applied Sciences
12
10
10.3923/jeasci.2017.2715.2719
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85045303479&doi=10.3923%2fjeasci.2017.2715.2719&partnerID=40&md5=05fc20525c2833cfddf31fb9ac05df6a
Femoral neck fractures and prosthesis loosening are several biomechanical concerns in promoting the long term stability of hip arthroplasties. External high impact loading due to sideway falls may contribute to the risk of femoral fractures and joint failures. The purpose of this study is to investigate the biomechanical effects of hip resurfacing and total hip arthroplasty on the resulting stress and damage formation. Four loading conditions are considered in the analysis to represent sideway falls at different configurations. Finite element analysis is performed using CT-based femoral bone model to predict the stress and damage formation in both arthroplasties. Stress shielding effects and potential of femoral fractures are observed in the cortical bone adjacent to the prosthesis. The results show that stress adaptation is predicted at both hip arthroplasties cases which lead to stress shielding problems especially in total hip arthroplasty. The variation of damage formation at trochanteric region suggested for femoral neck fractures and potential of implant loosening in both cases. © Medwell Journals, 2017.
Medwell Journals
1816949X
English
Article

author Abdullah A.H.; Todo M.; Nakashima Y.
spellingShingle Abdullah A.H.; Todo M.; Nakashima Y.
Stress and damage formation analysis in hip arthroplasties using CT-based finite element method
author_facet Abdullah A.H.; Todo M.; Nakashima Y.
author_sort Abdullah A.H.; Todo M.; Nakashima Y.
title Stress and damage formation analysis in hip arthroplasties using CT-based finite element method
title_short Stress and damage formation analysis in hip arthroplasties using CT-based finite element method
title_full Stress and damage formation analysis in hip arthroplasties using CT-based finite element method
title_fullStr Stress and damage formation analysis in hip arthroplasties using CT-based finite element method
title_full_unstemmed Stress and damage formation analysis in hip arthroplasties using CT-based finite element method
title_sort Stress and damage formation analysis in hip arthroplasties using CT-based finite element method
publishDate 2017
container_title Journal of Engineering and Applied Sciences
container_volume 12
container_issue 10
doi_str_mv 10.3923/jeasci.2017.2715.2719
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85045303479&doi=10.3923%2fjeasci.2017.2715.2719&partnerID=40&md5=05fc20525c2833cfddf31fb9ac05df6a
description Femoral neck fractures and prosthesis loosening are several biomechanical concerns in promoting the long term stability of hip arthroplasties. External high impact loading due to sideway falls may contribute to the risk of femoral fractures and joint failures. The purpose of this study is to investigate the biomechanical effects of hip resurfacing and total hip arthroplasty on the resulting stress and damage formation. Four loading conditions are considered in the analysis to represent sideway falls at different configurations. Finite element analysis is performed using CT-based femoral bone model to predict the stress and damage formation in both arthroplasties. Stress shielding effects and potential of femoral fractures are observed in the cortical bone adjacent to the prosthesis. The results show that stress adaptation is predicted at both hip arthroplasties cases which lead to stress shielding problems especially in total hip arthroplasty. The variation of damage formation at trochanteric region suggested for femoral neck fractures and potential of implant loosening in both cases. © Medwell Journals, 2017.
publisher Medwell Journals
issn 1816949X
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1809677908825866240