Relative humidity sensor based on MWCNTs-doped polymer microfiber
A relative humidity sensor based on Multi Walled Carbon Nanotubes (MWCNTs) doped with polymer Poly(methyl methacryate) was proposed in this paper. The fabrication technique applied in this paper is a simple direct drawing method that was able to produce a uniform waist microfiber with a minimum diam...
Published in: | 2017 7th IEEE International Conference on System Engineering and Technology, ICSET 2017 - Proceedings |
---|---|
Main Author: | |
Format: | Conference paper |
Language: | English |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041414745&doi=10.1109%2fICSEngT.2017.8123440&partnerID=40&md5=98baf87c8dff1ee8517ef95969502da0 |
id |
2-s2.0-85041414745 |
---|---|
spelling |
2-s2.0-85041414745 Isa N.M.; Irawati N.; Rahman H.A.; Yusoff M.H.M.; Harun S.W.; Ahmad F. Relative humidity sensor based on MWCNTs-doped polymer microfiber 2017 2017 7th IEEE International Conference on System Engineering and Technology, ICSET 2017 - Proceedings 10.1109/ICSEngT.2017.8123440 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041414745&doi=10.1109%2fICSEngT.2017.8123440&partnerID=40&md5=98baf87c8dff1ee8517ef95969502da0 A relative humidity sensor based on Multi Walled Carbon Nanotubes (MWCNTs) doped with polymer Poly(methyl methacryate) was proposed in this paper. The fabrication technique applied in this paper is a simple direct drawing method that was able to produce a uniform waist microfiber with a minimum diameter of 5 μm with a length of 5 mm. This microfiber was tested on a different range of relative humidity from 45% to 80%. Performance of the fabricated sensor were then analyzed, focusing at the sensitivity of undoped and MWCNTs-doped polymer microfiber. Based on the results, MWCNTs-doped polymer microfiber exhibits higher sensitivities and better resolution compared to undoped polymer microfiber, with sensitivity and resolution obtained at 0.3341 dBm/% and 1.649% respectively. Indeed, the sensor exhibited a high reliability as well as repeatability. Therefore, this study provides a good platform for enhancing the concept of doping nanomaterials like MWCNTs into PMMA for a chemical and biosensor application. © 2017 IEEE. Institute of Electrical and Electronics Engineers Inc. English Conference paper |
author |
Isa N.M.; Irawati N.; Rahman H.A.; Yusoff M.H.M.; Harun S.W.; Ahmad F. |
spellingShingle |
Isa N.M.; Irawati N.; Rahman H.A.; Yusoff M.H.M.; Harun S.W.; Ahmad F. Relative humidity sensor based on MWCNTs-doped polymer microfiber |
author_facet |
Isa N.M.; Irawati N.; Rahman H.A.; Yusoff M.H.M.; Harun S.W.; Ahmad F. |
author_sort |
Isa N.M.; Irawati N.; Rahman H.A.; Yusoff M.H.M.; Harun S.W.; Ahmad F. |
title |
Relative humidity sensor based on MWCNTs-doped polymer microfiber |
title_short |
Relative humidity sensor based on MWCNTs-doped polymer microfiber |
title_full |
Relative humidity sensor based on MWCNTs-doped polymer microfiber |
title_fullStr |
Relative humidity sensor based on MWCNTs-doped polymer microfiber |
title_full_unstemmed |
Relative humidity sensor based on MWCNTs-doped polymer microfiber |
title_sort |
Relative humidity sensor based on MWCNTs-doped polymer microfiber |
publishDate |
2017 |
container_title |
2017 7th IEEE International Conference on System Engineering and Technology, ICSET 2017 - Proceedings |
container_volume |
|
container_issue |
|
doi_str_mv |
10.1109/ICSEngT.2017.8123440 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041414745&doi=10.1109%2fICSEngT.2017.8123440&partnerID=40&md5=98baf87c8dff1ee8517ef95969502da0 |
description |
A relative humidity sensor based on Multi Walled Carbon Nanotubes (MWCNTs) doped with polymer Poly(methyl methacryate) was proposed in this paper. The fabrication technique applied in this paper is a simple direct drawing method that was able to produce a uniform waist microfiber with a minimum diameter of 5 μm with a length of 5 mm. This microfiber was tested on a different range of relative humidity from 45% to 80%. Performance of the fabricated sensor were then analyzed, focusing at the sensitivity of undoped and MWCNTs-doped polymer microfiber. Based on the results, MWCNTs-doped polymer microfiber exhibits higher sensitivities and better resolution compared to undoped polymer microfiber, with sensitivity and resolution obtained at 0.3341 dBm/% and 1.649% respectively. Indeed, the sensor exhibited a high reliability as well as repeatability. Therefore, this study provides a good platform for enhancing the concept of doping nanomaterials like MWCNTs into PMMA for a chemical and biosensor application. © 2017 IEEE. |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
issn |
|
language |
English |
format |
Conference paper |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1814778508743802880 |