Experimental investigation on box-up cold-formed steel columns in fire

Cold-formed steel is a popular material with various advantages. Its easy production and assembly give engineer an option to speed the construction process. However, thinness relates to the major issue of buckling, especially when dealing with high temperature. The unprotected cold-formed steel beha...

Full description

Bibliographic Details
Published in:International Journal of GEOMATE
Main Author: Muftah F.; Sani M.S.H.M.; Osman A.R.; Mohammad S.; Ngian S.P.
Format: Article
Language:English
Published: GEOMATE International Society 2018
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041208895&doi=10.21660%2f2018.44.3538&partnerID=40&md5=7d1a7846e5bbf8676a8fb17402c3f5ec
id 2-s2.0-85041208895
spelling 2-s2.0-85041208895
Muftah F.; Sani M.S.H.M.; Osman A.R.; Mohammad S.; Ngian S.P.
Experimental investigation on box-up cold-formed steel columns in fire
2018
International Journal of GEOMATE
14
44
10.21660/2018.44.3538
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041208895&doi=10.21660%2f2018.44.3538&partnerID=40&md5=7d1a7846e5bbf8676a8fb17402c3f5ec
Cold-formed steel is a popular material with various advantages. Its easy production and assembly give engineer an option to speed the construction process. However, thinness relates to the major issue of buckling, especially when dealing with high temperature. The unprotected cold-formed steel behaviour under fire is expected to have a little strength as compared to hot-rolled steel. Information on such behaviour is still limited. Fire resistance testing on built-up box CFS column was presented in this paper. Two fire resistance tests were carried out under compression load. The Standard ISO 834 Fire Resistance Test under 50% and 70% degree of utilisation measured the temperatures at several points of the steel column surface by using a surface thermocouple and axial column deformation. For reference purpose, one same static test at ambient temperature was carried out to assess the load bearing capacity. Results found that the failure temperature of built-up CFS could reach up to 515 °C and 443 °C within 8 minutes and 7 minutes resistant time for 50 % and 70% degree of utilisation, respectively. Based on deformation analysis, buckling temperature of the column was 448 °C and 394 °C with a critical time of 7 minutes for 50 % and 70% degree of utilisation, respectively. This concluded that the higher degree of utilisation results in lower critical temperatures of the columns. © 2018, Int. J. of GEOMATE.
GEOMATE International Society
21862982
English
Article
All Open Access; Gold Open Access
author Muftah F.; Sani M.S.H.M.; Osman A.R.; Mohammad S.; Ngian S.P.
spellingShingle Muftah F.; Sani M.S.H.M.; Osman A.R.; Mohammad S.; Ngian S.P.
Experimental investigation on box-up cold-formed steel columns in fire
author_facet Muftah F.; Sani M.S.H.M.; Osman A.R.; Mohammad S.; Ngian S.P.
author_sort Muftah F.; Sani M.S.H.M.; Osman A.R.; Mohammad S.; Ngian S.P.
title Experimental investigation on box-up cold-formed steel columns in fire
title_short Experimental investigation on box-up cold-formed steel columns in fire
title_full Experimental investigation on box-up cold-formed steel columns in fire
title_fullStr Experimental investigation on box-up cold-formed steel columns in fire
title_full_unstemmed Experimental investigation on box-up cold-formed steel columns in fire
title_sort Experimental investigation on box-up cold-formed steel columns in fire
publishDate 2018
container_title International Journal of GEOMATE
container_volume 14
container_issue 44
doi_str_mv 10.21660/2018.44.3538
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041208895&doi=10.21660%2f2018.44.3538&partnerID=40&md5=7d1a7846e5bbf8676a8fb17402c3f5ec
description Cold-formed steel is a popular material with various advantages. Its easy production and assembly give engineer an option to speed the construction process. However, thinness relates to the major issue of buckling, especially when dealing with high temperature. The unprotected cold-formed steel behaviour under fire is expected to have a little strength as compared to hot-rolled steel. Information on such behaviour is still limited. Fire resistance testing on built-up box CFS column was presented in this paper. Two fire resistance tests were carried out under compression load. The Standard ISO 834 Fire Resistance Test under 50% and 70% degree of utilisation measured the temperatures at several points of the steel column surface by using a surface thermocouple and axial column deformation. For reference purpose, one same static test at ambient temperature was carried out to assess the load bearing capacity. Results found that the failure temperature of built-up CFS could reach up to 515 °C and 443 °C within 8 minutes and 7 minutes resistant time for 50 % and 70% degree of utilisation, respectively. Based on deformation analysis, buckling temperature of the column was 448 °C and 394 °C with a critical time of 7 minutes for 50 % and 70% degree of utilisation, respectively. This concluded that the higher degree of utilisation results in lower critical temperatures of the columns. © 2018, Int. J. of GEOMATE.