Testing and analysis of cold-formed steel channel section with notch

Cold-formed steel (CFS) channel section is a construction material that often been used in the building and still in the research for utilizing in structural element. The advantages of the CFS channel section such as lightweight, anti-corrosion and etc are becoming so interesting in selecting it as...

Full description

Bibliographic Details
Published in:International Journal of GEOMATE
Main Author: Sani M.S.H.M.; Muftah F.; Ismail M.I.
Format: Article
Language:English
Published: GEOMATE International Society 2018
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85040938307&doi=10.21660%2f2018.43.3539&partnerID=40&md5=84543ca375de55bd09d913a8d48d14c5
id 2-s2.0-85040938307
spelling 2-s2.0-85040938307
Sani M.S.H.M.; Muftah F.; Ismail M.I.
Testing and analysis of cold-formed steel channel section with notch
2018
International Journal of GEOMATE
14
43
10.21660/2018.43.3539
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85040938307&doi=10.21660%2f2018.43.3539&partnerID=40&md5=84543ca375de55bd09d913a8d48d14c5
Cold-formed steel (CFS) channel section is a construction material that often been used in the building and still in the research for utilizing in structural element. The advantages of the CFS channel section such as lightweight, anti-corrosion and etc are becoming so interesting in selecting it as a roof purlin, roof truss system and storage rack. For having the structural element with the strong, safe and stable condition, the study of the CFS with the notch is carried out to determine the behavior. The parametric study is taking place to determine the suitability of notch pattern whether the notch depth and spacing are affecting the ultimate load of the CFS channel section column and beam. The study of the CFS channel section is divided into two parts, the first part is to examine the ultimate load of the column in varies of notch depth and the second part is to determine the ultimate load of the beam in varies of notch spacing. By referring the study of the notch depth on CFS channel column section, the result of the ultimate load is obtained to have the reduction about 19-80% of the variation of notch depth when compared with the normal section. Although, the CFS channel beam section with variation notch depth is influenced by approximately 4-14% when compared with CFS channel normal beam section.
GEOMATE International Society
21862982
English
Article
All Open Access; Gold Open Access
author Sani M.S.H.M.; Muftah F.; Ismail M.I.
spellingShingle Sani M.S.H.M.; Muftah F.; Ismail M.I.
Testing and analysis of cold-formed steel channel section with notch
author_facet Sani M.S.H.M.; Muftah F.; Ismail M.I.
author_sort Sani M.S.H.M.; Muftah F.; Ismail M.I.
title Testing and analysis of cold-formed steel channel section with notch
title_short Testing and analysis of cold-formed steel channel section with notch
title_full Testing and analysis of cold-formed steel channel section with notch
title_fullStr Testing and analysis of cold-formed steel channel section with notch
title_full_unstemmed Testing and analysis of cold-formed steel channel section with notch
title_sort Testing and analysis of cold-formed steel channel section with notch
publishDate 2018
container_title International Journal of GEOMATE
container_volume 14
container_issue 43
doi_str_mv 10.21660/2018.43.3539
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85040938307&doi=10.21660%2f2018.43.3539&partnerID=40&md5=84543ca375de55bd09d913a8d48d14c5
description Cold-formed steel (CFS) channel section is a construction material that often been used in the building and still in the research for utilizing in structural element. The advantages of the CFS channel section such as lightweight, anti-corrosion and etc are becoming so interesting in selecting it as a roof purlin, roof truss system and storage rack. For having the structural element with the strong, safe and stable condition, the study of the CFS with the notch is carried out to determine the behavior. The parametric study is taking place to determine the suitability of notch pattern whether the notch depth and spacing are affecting the ultimate load of the CFS channel section column and beam. The study of the CFS channel section is divided into two parts, the first part is to examine the ultimate load of the column in varies of notch depth and the second part is to determine the ultimate load of the beam in varies of notch spacing. By referring the study of the notch depth on CFS channel column section, the result of the ultimate load is obtained to have the reduction about 19-80% of the variation of notch depth when compared with the normal section. Although, the CFS channel beam section with variation notch depth is influenced by approximately 4-14% when compared with CFS channel normal beam section.
publisher GEOMATE International Society
issn 21862982
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677908203012096