Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. Ma...

Full description

Bibliographic Details
Published in:Imaging Science in Dentistry
Main Author: Yusof M.Y.P.M.; Abdul Rahman N.L.; Ahmad Asri A.A.; Othman N.I.; Mokhtar I.W.
Format: Article
Language:English
Published: Korean Academy of Oral and Maxillofacial Radiology 2017
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85038612056&doi=10.5624%2fisd.2017.47.4.233&partnerID=40&md5=85eb2c5370664e124e9e4618fbcac405
id 2-s2.0-85038612056
spelling 2-s2.0-85038612056
Yusof M.Y.P.M.; Abdul Rahman N.L.; Ahmad Asri A.A.; Othman N.I.; Mokhtar I.W.
Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study
2017
Imaging Science in Dentistry
47
4
10.5624/isd.2017.47.4.233
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85038612056&doi=10.5624%2fisd.2017.47.4.233&partnerID=40&md5=85eb2c5370664e124e9e4618fbcac405
Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients. © 2017 by Korean Academy of Oral and Maxillofacial Radiology.
Korean Academy of Oral and Maxillofacial Radiology
22337822
English
Article
All Open Access; Gold Open Access; Green Open Access
author Yusof M.Y.P.M.; Abdul Rahman N.L.; Ahmad Asri A.A.; Othman N.I.; Mokhtar I.W.
spellingShingle Yusof M.Y.P.M.; Abdul Rahman N.L.; Ahmad Asri A.A.; Othman N.I.; Mokhtar I.W.
Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study
author_facet Yusof M.Y.P.M.; Abdul Rahman N.L.; Ahmad Asri A.A.; Othman N.I.; Mokhtar I.W.
author_sort Yusof M.Y.P.M.; Abdul Rahman N.L.; Ahmad Asri A.A.; Othman N.I.; Mokhtar I.W.
title Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study
title_short Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study
title_full Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study
title_fullStr Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study
title_full_unstemmed Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study
title_sort Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study
publishDate 2017
container_title Imaging Science in Dentistry
container_volume 47
container_issue 4
doi_str_mv 10.5624/isd.2017.47.4.233
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85038612056&doi=10.5624%2fisd.2017.47.4.233&partnerID=40&md5=85eb2c5370664e124e9e4618fbcac405
description Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients. © 2017 by Korean Academy of Oral and Maxillofacial Radiology.
publisher Korean Academy of Oral and Maxillofacial Radiology
issn 22337822
language English
format Article
accesstype All Open Access; Gold Open Access; Green Open Access
record_format scopus
collection Scopus
_version_ 1820775473014112256