Mass Flow Analysis of Mercury Transformation and Effect of Seawater Flue Gas Desulfurization on Mercury Removal in a Full-Scale Coal-Fired Power Plant

To understand the mercury speciation and mass flow in a full-scale bituminous coal-fired power plant equipped with a selective catalytic reduction (SCR) unit, an electrostatic precipitator (ESP), and a seawater flue gas desulfurization (SWFGD) scrubber, the evolution and emission of mercury was syst...

Full description

Bibliographic Details
Published in:Energy and Fuels
Main Author: Su S.; Liu L.; Wang L.; Syed-Hassan S.S.A.; Kong F.; Hu S.; Wang Y.; Jiang L.; Xu K.; Zhang A.; Xiang J.
Format: Article
Language:English
Published: American Chemical Society 2017
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032855553&doi=10.1021%2facs.energyfuels.7b02029&partnerID=40&md5=b029bc44c083833eabc12b740d40c83a
id 2-s2.0-85032855553
spelling 2-s2.0-85032855553
Su S.; Liu L.; Wang L.; Syed-Hassan S.S.A.; Kong F.; Hu S.; Wang Y.; Jiang L.; Xu K.; Zhang A.; Xiang J.
Mass Flow Analysis of Mercury Transformation and Effect of Seawater Flue Gas Desulfurization on Mercury Removal in a Full-Scale Coal-Fired Power Plant
2017
Energy and Fuels
31
10
10.1021/acs.energyfuels.7b02029
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032855553&doi=10.1021%2facs.energyfuels.7b02029&partnerID=40&md5=b029bc44c083833eabc12b740d40c83a
To understand the mercury speciation and mass flow in a full-scale bituminous coal-fired power plant equipped with a selective catalytic reduction (SCR) unit, an electrostatic precipitator (ESP), and a seawater flue gas desulfurization (SWFGD) scrubber, the evolution and emission of mercury was systematically measured and analyzed. The results showed that the elemental mercury (Hg0) was oxidized mainly through heterogeneous oxidation, especially in SCR, which transformed 57-64% of elemental mercury (Hg0) to oxidized mercury (Hg2+). It changed the concentrations of different mercury species and then increased the Hg2+ removal efficiencies of SWFGD, which ranged from 67 to 82%. A total of 8.24-11.54% of mercury was adsorbed by fly ash to form particulate-bound mercury (HgP) and subsequently removed by the ESP. Mass flow and mass distribution of mercury indicated that most mercury was removed and retained in the SWFGD. The heterogeneous oxidation of Hg0 in SCR and then absorption of Hg2+ by SWFGD significantly enhanced the mercury removal in the studied coal-fired power plant, although a part of Hg2+ absorbed in SWFGD was reduced and released back to the flue gas. Hg2+ was a little more than Hg0 in the flue gas emitted to the atmosphere. In addition, the SWFGD system without limestone addition may be beneficial for decreasing the re-emission of Hg0. The mercury emission factor at the power plant is 4.098 g/TJ, which is lower than that at other power plants without SCR. The configuration of SCR + ESP + SWFGD enhances the co-benefit mercury control. © 2017 American Chemical Society.
American Chemical Society
8870624
English
Article

author Su S.; Liu L.; Wang L.; Syed-Hassan S.S.A.; Kong F.; Hu S.; Wang Y.; Jiang L.; Xu K.; Zhang A.; Xiang J.
spellingShingle Su S.; Liu L.; Wang L.; Syed-Hassan S.S.A.; Kong F.; Hu S.; Wang Y.; Jiang L.; Xu K.; Zhang A.; Xiang J.
Mass Flow Analysis of Mercury Transformation and Effect of Seawater Flue Gas Desulfurization on Mercury Removal in a Full-Scale Coal-Fired Power Plant
author_facet Su S.; Liu L.; Wang L.; Syed-Hassan S.S.A.; Kong F.; Hu S.; Wang Y.; Jiang L.; Xu K.; Zhang A.; Xiang J.
author_sort Su S.; Liu L.; Wang L.; Syed-Hassan S.S.A.; Kong F.; Hu S.; Wang Y.; Jiang L.; Xu K.; Zhang A.; Xiang J.
title Mass Flow Analysis of Mercury Transformation and Effect of Seawater Flue Gas Desulfurization on Mercury Removal in a Full-Scale Coal-Fired Power Plant
title_short Mass Flow Analysis of Mercury Transformation and Effect of Seawater Flue Gas Desulfurization on Mercury Removal in a Full-Scale Coal-Fired Power Plant
title_full Mass Flow Analysis of Mercury Transformation and Effect of Seawater Flue Gas Desulfurization on Mercury Removal in a Full-Scale Coal-Fired Power Plant
title_fullStr Mass Flow Analysis of Mercury Transformation and Effect of Seawater Flue Gas Desulfurization on Mercury Removal in a Full-Scale Coal-Fired Power Plant
title_full_unstemmed Mass Flow Analysis of Mercury Transformation and Effect of Seawater Flue Gas Desulfurization on Mercury Removal in a Full-Scale Coal-Fired Power Plant
title_sort Mass Flow Analysis of Mercury Transformation and Effect of Seawater Flue Gas Desulfurization on Mercury Removal in a Full-Scale Coal-Fired Power Plant
publishDate 2017
container_title Energy and Fuels
container_volume 31
container_issue 10
doi_str_mv 10.1021/acs.energyfuels.7b02029
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032855553&doi=10.1021%2facs.energyfuels.7b02029&partnerID=40&md5=b029bc44c083833eabc12b740d40c83a
description To understand the mercury speciation and mass flow in a full-scale bituminous coal-fired power plant equipped with a selective catalytic reduction (SCR) unit, an electrostatic precipitator (ESP), and a seawater flue gas desulfurization (SWFGD) scrubber, the evolution and emission of mercury was systematically measured and analyzed. The results showed that the elemental mercury (Hg0) was oxidized mainly through heterogeneous oxidation, especially in SCR, which transformed 57-64% of elemental mercury (Hg0) to oxidized mercury (Hg2+). It changed the concentrations of different mercury species and then increased the Hg2+ removal efficiencies of SWFGD, which ranged from 67 to 82%. A total of 8.24-11.54% of mercury was adsorbed by fly ash to form particulate-bound mercury (HgP) and subsequently removed by the ESP. Mass flow and mass distribution of mercury indicated that most mercury was removed and retained in the SWFGD. The heterogeneous oxidation of Hg0 in SCR and then absorption of Hg2+ by SWFGD significantly enhanced the mercury removal in the studied coal-fired power plant, although a part of Hg2+ absorbed in SWFGD was reduced and released back to the flue gas. Hg2+ was a little more than Hg0 in the flue gas emitted to the atmosphere. In addition, the SWFGD system without limestone addition may be beneficial for decreasing the re-emission of Hg0. The mercury emission factor at the power plant is 4.098 g/TJ, which is lower than that at other power plants without SCR. The configuration of SCR + ESP + SWFGD enhances the co-benefit mercury control. © 2017 American Chemical Society.
publisher American Chemical Society
issn 8870624
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1809677785639157760