Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique

This research attempted to measure chicken intramuscular fat content using improved ultrasound B-mode images and image segmentation. Adapted B-mode imaging is proposed to increase the positioning accuracy of B-mode images with the objective to correct the phase error due to the use of predetermined...

Full description

Bibliographic Details
Published in:Journal of ICT Research and Applications
Main Author: Buniyamin N.; Abdul Halim M.H.
Format: Article
Language:English
Published: Institute for Research and Community Services, Institut Teknologi Bandung 2017
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85020618860&doi=10.5614%2fitbj.ict.res.appl.2017.11.1.1&partnerID=40&md5=d8d17d3ad56aaca44fbd73e0e4000675
id 2-s2.0-85020618860
spelling 2-s2.0-85020618860
Buniyamin N.; Abdul Halim M.H.
Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique
2017
Journal of ICT Research and Applications
11
1
10.5614/itbj.ict.res.appl.2017.11.1.1
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85020618860&doi=10.5614%2fitbj.ict.res.appl.2017.11.1.1&partnerID=40&md5=d8d17d3ad56aaca44fbd73e0e4000675
This research attempted to measure chicken intramuscular fat content using improved ultrasound B-mode images and image segmentation. Adapted B-mode imaging is proposed to increase the positioning accuracy of B-mode images with the objective to correct the phase error due to the use of predetermined ultrasonic velocity in conventional B-mode imaging. The predetermined velocity is replaced by actual velocity measured using A-mode imaging. The positioning accuracy of adapted and conventional B-mode imaging was validated using 144 chicken samples. The adapted B-mode image had better positioning accuracy compared to a conventional B-mode image since the method used was able to detect the thickness of the chicken sample with a lower mean difference (0.036±0.034mm vs. 0.113±0.010). Both methods were then applied for measurement of intramuscular fat content. The histogram mean and the percentage of fat pixels were the B-mode image characteristics that were extracted and their correlation with the fat content, measured using the Soxhlet method, was analyzed. The properties of the adapted B-mode images correlated better with the Soxhlet-measured fat content compared to the properties of the conventional B-mode images as reflected in the correlation coefficient, r, for the histogram mean (0.357 vs. 0.129) and the percentage of fat pixels (0.406 vs. 0.289). The results indicate the potential of using ultrasound adapted B-mode imaging to measure chicken intramuscular fat. © 2017 Published by ITB Journal Publisher.
Institute for Research and Community Services, Institut Teknologi Bandung
23375787
English
Article
All Open Access; Gold Open Access; Green Open Access
author Buniyamin N.; Abdul Halim M.H.
spellingShingle Buniyamin N.; Abdul Halim M.H.
Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique
author_facet Buniyamin N.; Abdul Halim M.H.
author_sort Buniyamin N.; Abdul Halim M.H.
title Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique
title_short Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique
title_full Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique
title_fullStr Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique
title_full_unstemmed Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique
title_sort Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique
publishDate 2017
container_title Journal of ICT Research and Applications
container_volume 11
container_issue 1
doi_str_mv 10.5614/itbj.ict.res.appl.2017.11.1.1
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85020618860&doi=10.5614%2fitbj.ict.res.appl.2017.11.1.1&partnerID=40&md5=d8d17d3ad56aaca44fbd73e0e4000675
description This research attempted to measure chicken intramuscular fat content using improved ultrasound B-mode images and image segmentation. Adapted B-mode imaging is proposed to increase the positioning accuracy of B-mode images with the objective to correct the phase error due to the use of predetermined ultrasonic velocity in conventional B-mode imaging. The predetermined velocity is replaced by actual velocity measured using A-mode imaging. The positioning accuracy of adapted and conventional B-mode imaging was validated using 144 chicken samples. The adapted B-mode image had better positioning accuracy compared to a conventional B-mode image since the method used was able to detect the thickness of the chicken sample with a lower mean difference (0.036±0.034mm vs. 0.113±0.010). Both methods were then applied for measurement of intramuscular fat content. The histogram mean and the percentage of fat pixels were the B-mode image characteristics that were extracted and their correlation with the fat content, measured using the Soxhlet method, was analyzed. The properties of the adapted B-mode images correlated better with the Soxhlet-measured fat content compared to the properties of the conventional B-mode images as reflected in the correlation coefficient, r, for the histogram mean (0.357 vs. 0.129) and the percentage of fat pixels (0.406 vs. 0.289). The results indicate the potential of using ultrasound adapted B-mode imaging to measure chicken intramuscular fat. © 2017 Published by ITB Journal Publisher.
publisher Institute for Research and Community Services, Institut Teknologi Bandung
issn 23375787
language English
format Article
accesstype All Open Access; Gold Open Access; Green Open Access
record_format scopus
collection Scopus
_version_ 1820775473497505792