Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique
This research attempted to measure chicken intramuscular fat content using improved ultrasound B-mode images and image segmentation. Adapted B-mode imaging is proposed to increase the positioning accuracy of B-mode images with the objective to correct the phase error due to the use of predetermined...
Published in: | Journal of ICT Research and Applications |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
Institute for Research and Community Services, Institut Teknologi Bandung
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85020618860&doi=10.5614%2fitbj.ict.res.appl.2017.11.1.1&partnerID=40&md5=d8d17d3ad56aaca44fbd73e0e4000675 |
id |
2-s2.0-85020618860 |
---|---|
spelling |
2-s2.0-85020618860 Buniyamin N.; Abdul Halim M.H. Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique 2017 Journal of ICT Research and Applications 11 1 10.5614/itbj.ict.res.appl.2017.11.1.1 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85020618860&doi=10.5614%2fitbj.ict.res.appl.2017.11.1.1&partnerID=40&md5=d8d17d3ad56aaca44fbd73e0e4000675 This research attempted to measure chicken intramuscular fat content using improved ultrasound B-mode images and image segmentation. Adapted B-mode imaging is proposed to increase the positioning accuracy of B-mode images with the objective to correct the phase error due to the use of predetermined ultrasonic velocity in conventional B-mode imaging. The predetermined velocity is replaced by actual velocity measured using A-mode imaging. The positioning accuracy of adapted and conventional B-mode imaging was validated using 144 chicken samples. The adapted B-mode image had better positioning accuracy compared to a conventional B-mode image since the method used was able to detect the thickness of the chicken sample with a lower mean difference (0.036±0.034mm vs. 0.113±0.010). Both methods were then applied for measurement of intramuscular fat content. The histogram mean and the percentage of fat pixels were the B-mode image characteristics that were extracted and their correlation with the fat content, measured using the Soxhlet method, was analyzed. The properties of the adapted B-mode images correlated better with the Soxhlet-measured fat content compared to the properties of the conventional B-mode images as reflected in the correlation coefficient, r, for the histogram mean (0.357 vs. 0.129) and the percentage of fat pixels (0.406 vs. 0.289). The results indicate the potential of using ultrasound adapted B-mode imaging to measure chicken intramuscular fat. © 2017 Published by ITB Journal Publisher. Institute for Research and Community Services, Institut Teknologi Bandung 23375787 English Article All Open Access; Gold Open Access; Green Open Access |
author |
Buniyamin N.; Abdul Halim M.H. |
spellingShingle |
Buniyamin N.; Abdul Halim M.H. Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique |
author_facet |
Buniyamin N.; Abdul Halim M.H. |
author_sort |
Buniyamin N.; Abdul Halim M.H. |
title |
Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique |
title_short |
Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique |
title_full |
Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique |
title_fullStr |
Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique |
title_full_unstemmed |
Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique |
title_sort |
Adjusting time of flight in ultrasound B-mode imaging for accurate measurement of fat using image segmentation technique |
publishDate |
2017 |
container_title |
Journal of ICT Research and Applications |
container_volume |
11 |
container_issue |
1 |
doi_str_mv |
10.5614/itbj.ict.res.appl.2017.11.1.1 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85020618860&doi=10.5614%2fitbj.ict.res.appl.2017.11.1.1&partnerID=40&md5=d8d17d3ad56aaca44fbd73e0e4000675 |
description |
This research attempted to measure chicken intramuscular fat content using improved ultrasound B-mode images and image segmentation. Adapted B-mode imaging is proposed to increase the positioning accuracy of B-mode images with the objective to correct the phase error due to the use of predetermined ultrasonic velocity in conventional B-mode imaging. The predetermined velocity is replaced by actual velocity measured using A-mode imaging. The positioning accuracy of adapted and conventional B-mode imaging was validated using 144 chicken samples. The adapted B-mode image had better positioning accuracy compared to a conventional B-mode image since the method used was able to detect the thickness of the chicken sample with a lower mean difference (0.036±0.034mm vs. 0.113±0.010). Both methods were then applied for measurement of intramuscular fat content. The histogram mean and the percentage of fat pixels were the B-mode image characteristics that were extracted and their correlation with the fat content, measured using the Soxhlet method, was analyzed. The properties of the adapted B-mode images correlated better with the Soxhlet-measured fat content compared to the properties of the conventional B-mode images as reflected in the correlation coefficient, r, for the histogram mean (0.357 vs. 0.129) and the percentage of fat pixels (0.406 vs. 0.289). The results indicate the potential of using ultrasound adapted B-mode imaging to measure chicken intramuscular fat. © 2017 Published by ITB Journal Publisher. |
publisher |
Institute for Research and Community Services, Institut Teknologi Bandung |
issn |
23375787 |
language |
English |
format |
Article |
accesstype |
All Open Access; Gold Open Access; Green Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1820775473497505792 |