Experimental study on seismic behavior of repaired single and double unit tunnel form building under in-plane cyclic loading

One-third scale single and double unit three-story tunnel form buildings (TFB) were designed, constructed and tested under quasi-static in-plane lateral cyclic loading. Both of the prototype specimens were designed using BS8110 to represent the state-of-the-art reinforced concrete tunnel form buildi...

Full description

Bibliographic Details
Published in:Malaysian Construction Research Journal
Main Author: Anudai S.; Hamid N.H.A.; Hashim M.H.M.
Format: Article
Language:English
Published: Construction Research Institute of Malaysia 2016
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85015345217&partnerID=40&md5=dfbd36bea0416e9832837186f9dab009
id 2-s2.0-85015345217
spelling 2-s2.0-85015345217
Anudai S.; Hamid N.H.A.; Hashim M.H.M.
Experimental study on seismic behavior of repaired single and double unit tunnel form building under in-plane cyclic loading
2016
Malaysian Construction Research Journal
19
2

https://www.scopus.com/inward/record.uri?eid=2-s2.0-85015345217&partnerID=40&md5=dfbd36bea0416e9832837186f9dab009
One-third scale single and double unit three-story tunnel form buildings (TFB) were designed, constructed and tested under quasi-static in-plane lateral cyclic loading. Both of the prototype specimens were designed using BS8110 to represent the state-of-the-art reinforced concrete tunnel form buildings in Malaysia. The aim of this paper is to compare the seismic performance of repaired single and double TFB in the laboratory using Carbon Fibred Reinforced Polymer (CFRP), steel angle and steel plate. The repair and retrofit technique is adopted herein to increase the lateral strength capacity, stiffness, ductility and equivalent viscous damping of the TFB so that it can withstand the earthquake excitations. Both specimens were tested starting from ±0.01%, ±0.1%, ±0.25%, ±0.5%, ±0.75%, ±1.0% and ±1.25% drifts until severe damage was observed. Then, the damage single unit TFB was repaired and strengthened using CFRP, steel angle and steel plate. Meanwhile, the damage double unit TFB was repaired and retrofitted using additional shear wall, steel angle and CFRP. In order to assess their seismic performance under in-plane cyclic loading, the experimental results from both specimens before and after repaired were compared with each other. Results show that the lateral strength capacity of repaired double unit TFB increases by 54% as compare to repaired single unit TFB and no significant damage was observed on failure mode for both specimens. The stiffness and ductility for repaired double unit TFB was increased by 4% and 2%, respectively as compared to repaired single unit TFB. It can be concluded that the proposed repaired and retrofitted technique and material used such as CFRP, steel plate, steel angle and additional of shear wall can be used for damaged tunnel form buildings after the moderate or strong earthquakes. © 2016, Construction Research Institute of Malaysia. All rights reserved.
Construction Research Institute of Malaysia
19853807
English
Article

author Anudai S.; Hamid N.H.A.; Hashim M.H.M.
spellingShingle Anudai S.; Hamid N.H.A.; Hashim M.H.M.
Experimental study on seismic behavior of repaired single and double unit tunnel form building under in-plane cyclic loading
author_facet Anudai S.; Hamid N.H.A.; Hashim M.H.M.
author_sort Anudai S.; Hamid N.H.A.; Hashim M.H.M.
title Experimental study on seismic behavior of repaired single and double unit tunnel form building under in-plane cyclic loading
title_short Experimental study on seismic behavior of repaired single and double unit tunnel form building under in-plane cyclic loading
title_full Experimental study on seismic behavior of repaired single and double unit tunnel form building under in-plane cyclic loading
title_fullStr Experimental study on seismic behavior of repaired single and double unit tunnel form building under in-plane cyclic loading
title_full_unstemmed Experimental study on seismic behavior of repaired single and double unit tunnel form building under in-plane cyclic loading
title_sort Experimental study on seismic behavior of repaired single and double unit tunnel form building under in-plane cyclic loading
publishDate 2016
container_title Malaysian Construction Research Journal
container_volume 19
container_issue 2
doi_str_mv
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85015345217&partnerID=40&md5=dfbd36bea0416e9832837186f9dab009
description One-third scale single and double unit three-story tunnel form buildings (TFB) were designed, constructed and tested under quasi-static in-plane lateral cyclic loading. Both of the prototype specimens were designed using BS8110 to represent the state-of-the-art reinforced concrete tunnel form buildings in Malaysia. The aim of this paper is to compare the seismic performance of repaired single and double TFB in the laboratory using Carbon Fibred Reinforced Polymer (CFRP), steel angle and steel plate. The repair and retrofit technique is adopted herein to increase the lateral strength capacity, stiffness, ductility and equivalent viscous damping of the TFB so that it can withstand the earthquake excitations. Both specimens were tested starting from ±0.01%, ±0.1%, ±0.25%, ±0.5%, ±0.75%, ±1.0% and ±1.25% drifts until severe damage was observed. Then, the damage single unit TFB was repaired and strengthened using CFRP, steel angle and steel plate. Meanwhile, the damage double unit TFB was repaired and retrofitted using additional shear wall, steel angle and CFRP. In order to assess their seismic performance under in-plane cyclic loading, the experimental results from both specimens before and after repaired were compared with each other. Results show that the lateral strength capacity of repaired double unit TFB increases by 54% as compare to repaired single unit TFB and no significant damage was observed on failure mode for both specimens. The stiffness and ductility for repaired double unit TFB was increased by 4% and 2%, respectively as compared to repaired single unit TFB. It can be concluded that the proposed repaired and retrofitted technique and material used such as CFRP, steel plate, steel angle and additional of shear wall can be used for damaged tunnel form buildings after the moderate or strong earthquakes. © 2016, Construction Research Institute of Malaysia. All rights reserved.
publisher Construction Research Institute of Malaysia
issn 19853807
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1809678161232789504