Development of Control System for Keropok Keping Drying Machine
This research is focused on the development of a control system for the keropok keping drying machine by using programmable logic controller (PLC) as the controller. The control panel and human machine interface (HMI) were developed for the machine. Experimental study was conducted to validate the H...
Published in: | MATEC Web of Conferences |
---|---|
Main Author: | |
Format: | Conference paper |
Language: | English |
Published: |
EDP Sciences
2016
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009080653&doi=10.1051%2fmatecconf%2f20178702016&partnerID=40&md5=ddc53b25da9c9fc1ce8647d2dff40962 |
id |
2-s2.0-85009080653 |
---|---|
spelling |
2-s2.0-85009080653 Leman M.N.; Mohamaddan S.; Mohamad Suffian M.S.Z.; Abang Mohd Mohtar A.M.A.; Mohtadzar N.A.A.; Junaidi N.; Julaihi S.A. Development of Control System for Keropok Keping Drying Machine 2016 MATEC Web of Conferences 87 10.1051/matecconf/20178702016 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009080653&doi=10.1051%2fmatecconf%2f20178702016&partnerID=40&md5=ddc53b25da9c9fc1ce8647d2dff40962 This research is focused on the development of a control system for the keropok keping drying machine by using programmable logic controller (PLC) as the controller. The control panel and human machine interface (HMI) were developed for the machine. Experimental study was conducted to validate the HMI speed data by the control panel speed display. The evaluation of the duty cycle (%) and current flow (amp) effect to the motor and fan speed were also conducted. The results showed that around 1 - 30 % and 1 - 3 % differences of the speed readings were recorded by the HMI for the motor and fan respectively. The percentage difference needs to be controlled as small as possible to ensure the HMI speed readings are more accurate. The linearity of the current flow curve to all duty cycle can be observed. The flow (amp) increases when the speed of dryer motor and fan increases. The development of the control system is expected to improve the operation of the keropok keping drying machine. © The Authors, published by EDP Sciences, 2017. EDP Sciences 2261236X English Conference paper All Open Access; Gold Open Access; Green Open Access |
author |
Leman M.N.; Mohamaddan S.; Mohamad Suffian M.S.Z.; Abang Mohd Mohtar A.M.A.; Mohtadzar N.A.A.; Junaidi N.; Julaihi S.A. |
spellingShingle |
Leman M.N.; Mohamaddan S.; Mohamad Suffian M.S.Z.; Abang Mohd Mohtar A.M.A.; Mohtadzar N.A.A.; Junaidi N.; Julaihi S.A. Development of Control System for Keropok Keping Drying Machine |
author_facet |
Leman M.N.; Mohamaddan S.; Mohamad Suffian M.S.Z.; Abang Mohd Mohtar A.M.A.; Mohtadzar N.A.A.; Junaidi N.; Julaihi S.A. |
author_sort |
Leman M.N.; Mohamaddan S.; Mohamad Suffian M.S.Z.; Abang Mohd Mohtar A.M.A.; Mohtadzar N.A.A.; Junaidi N.; Julaihi S.A. |
title |
Development of Control System for Keropok Keping Drying Machine |
title_short |
Development of Control System for Keropok Keping Drying Machine |
title_full |
Development of Control System for Keropok Keping Drying Machine |
title_fullStr |
Development of Control System for Keropok Keping Drying Machine |
title_full_unstemmed |
Development of Control System for Keropok Keping Drying Machine |
title_sort |
Development of Control System for Keropok Keping Drying Machine |
publishDate |
2016 |
container_title |
MATEC Web of Conferences |
container_volume |
87 |
container_issue |
|
doi_str_mv |
10.1051/matecconf/20178702016 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009080653&doi=10.1051%2fmatecconf%2f20178702016&partnerID=40&md5=ddc53b25da9c9fc1ce8647d2dff40962 |
description |
This research is focused on the development of a control system for the keropok keping drying machine by using programmable logic controller (PLC) as the controller. The control panel and human machine interface (HMI) were developed for the machine. Experimental study was conducted to validate the HMI speed data by the control panel speed display. The evaluation of the duty cycle (%) and current flow (amp) effect to the motor and fan speed were also conducted. The results showed that around 1 - 30 % and 1 - 3 % differences of the speed readings were recorded by the HMI for the motor and fan respectively. The percentage difference needs to be controlled as small as possible to ensure the HMI speed readings are more accurate. The linearity of the current flow curve to all duty cycle can be observed. The flow (amp) increases when the speed of dryer motor and fan increases. The development of the control system is expected to improve the operation of the keropok keping drying machine. © The Authors, published by EDP Sciences, 2017. |
publisher |
EDP Sciences |
issn |
2261236X |
language |
English |
format |
Conference paper |
accesstype |
All Open Access; Gold Open Access; Green Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1820775473933713408 |