Determination of heavy metals concentrations in Airborne Particulates Matter (APM) from Manjung district, Perak using Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer

Airborne particulates trace metals are considered as public health concern as it can enter human lungs through respiratory system. Generally, any substance that has been introduced to the atmosphere that can cause severe effects to living things and the environment is considered air pollution. Manju...

Full description

Bibliographic Details
Published in:AIP Conference Proceedings
Main Author: Arshad N.; Hamzah Z.; Wood A.K.; Saat A.; Alias M.
Format: Conference paper
Language:English
Published: American Institute of Physics Inc. 2015
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84997417424&doi=10.1063%2f1.4916878&partnerID=40&md5=37a14986ca72fe4b3173707a1635ca9e
id 2-s2.0-84997417424
spelling 2-s2.0-84997417424
Arshad N.; Hamzah Z.; Wood A.K.; Saat A.; Alias M.
Determination of heavy metals concentrations in Airborne Particulates Matter (APM) from Manjung district, Perak using Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer
2015
AIP Conference Proceedings
1659

10.1063/1.4916878
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84997417424&doi=10.1063%2f1.4916878&partnerID=40&md5=37a14986ca72fe4b3173707a1635ca9e
Airborne particulates trace metals are considered as public health concern as it can enter human lungs through respiratory system. Generally, any substance that has been introduced to the atmosphere that can cause severe effects to living things and the environment is considered air pollution. Manjung, Perak is one of the development districts that is active with industrial activities. There are many industrial activities surrounding Manjung District area such as coal fired power plant, quarries and iron smelting which may contribute to the air pollution into the environment. This study was done to measure the concentrations of Hg, U, Th, K, Cu, Fe, Cr, Zn, As, Se, Pb and Cd in the Airborne Particulate Matter (APM) collected at nine locations in Manjung District area within 15 km radius towards three directions (North, North-East and South-East) in 5 km intervals. The samples were collected using mini volume air sampler with cellulose filter through total suspended particulate (TSP). The sampler was set up for eight hours with the flow rate of 5 L/min. The filter was weighed before and after sample collection using microbalance, to get the amount of APM and kept in desiccator before analyzing. The measurement was done using calibrated Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer. The air particulate concentrations were found below the Malaysia Air Quality Guidelines for TSP (260 μg/m3). All of the metals concentrations were also lower than the guidelines set by World Health Organization (WHO), Ontario Ministry of the Environment and Argonne National Laboratory, USA NCRP (1975). From the concentrations, the enrichment factor were calculated. © 2015 AIP Publishing LLC.
American Institute of Physics Inc.
0094243X
English
Conference paper

author Arshad N.; Hamzah Z.; Wood A.K.; Saat A.; Alias M.
spellingShingle Arshad N.; Hamzah Z.; Wood A.K.; Saat A.; Alias M.
Determination of heavy metals concentrations in Airborne Particulates Matter (APM) from Manjung district, Perak using Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer
author_facet Arshad N.; Hamzah Z.; Wood A.K.; Saat A.; Alias M.
author_sort Arshad N.; Hamzah Z.; Wood A.K.; Saat A.; Alias M.
title Determination of heavy metals concentrations in Airborne Particulates Matter (APM) from Manjung district, Perak using Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer
title_short Determination of heavy metals concentrations in Airborne Particulates Matter (APM) from Manjung district, Perak using Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer
title_full Determination of heavy metals concentrations in Airborne Particulates Matter (APM) from Manjung district, Perak using Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer
title_fullStr Determination of heavy metals concentrations in Airborne Particulates Matter (APM) from Manjung district, Perak using Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer
title_full_unstemmed Determination of heavy metals concentrations in Airborne Particulates Matter (APM) from Manjung district, Perak using Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer
title_sort Determination of heavy metals concentrations in Airborne Particulates Matter (APM) from Manjung district, Perak using Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer
publishDate 2015
container_title AIP Conference Proceedings
container_volume 1659
container_issue
doi_str_mv 10.1063/1.4916878
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84997417424&doi=10.1063%2f1.4916878&partnerID=40&md5=37a14986ca72fe4b3173707a1635ca9e
description Airborne particulates trace metals are considered as public health concern as it can enter human lungs through respiratory system. Generally, any substance that has been introduced to the atmosphere that can cause severe effects to living things and the environment is considered air pollution. Manjung, Perak is one of the development districts that is active with industrial activities. There are many industrial activities surrounding Manjung District area such as coal fired power plant, quarries and iron smelting which may contribute to the air pollution into the environment. This study was done to measure the concentrations of Hg, U, Th, K, Cu, Fe, Cr, Zn, As, Se, Pb and Cd in the Airborne Particulate Matter (APM) collected at nine locations in Manjung District area within 15 km radius towards three directions (North, North-East and South-East) in 5 km intervals. The samples were collected using mini volume air sampler with cellulose filter through total suspended particulate (TSP). The sampler was set up for eight hours with the flow rate of 5 L/min. The filter was weighed before and after sample collection using microbalance, to get the amount of APM and kept in desiccator before analyzing. The measurement was done using calibrated Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer. The air particulate concentrations were found below the Malaysia Air Quality Guidelines for TSP (260 μg/m3). All of the metals concentrations were also lower than the guidelines set by World Health Organization (WHO), Ontario Ministry of the Environment and Argonne National Laboratory, USA NCRP (1975). From the concentrations, the enrichment factor were calculated. © 2015 AIP Publishing LLC.
publisher American Institute of Physics Inc.
issn 0094243X
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1823296165462933504