Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle

Intra-body communication (IBC) is a communication system that uses human body as a signal transmission medium. From previous research, two coupling methods of IBC were concluded which are capacitive coupling and galvanic coupling. This paper investigates the effect of human movement on IBC using the...

Full description

Bibliographic Details
Published in:IOP Conference Series: Materials Science and Engineering
Main Author: Ibrahim I.W.; Razak A.H.A.; Ahmad A.; Salleh M.K.M.
Format: Conference paper
Language:English
Published: Institute of Physics Publishing 2015
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84960844856&doi=10.1088%2f1757-899X%2f99%2f1%2f012027&partnerID=40&md5=443d355cee5ad37cabb3020bf74eafe2
id 2-s2.0-84960844856
spelling 2-s2.0-84960844856
Ibrahim I.W.; Razak A.H.A.; Ahmad A.; Salleh M.K.M.
Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
2015
IOP Conference Series: Materials Science and Engineering
99
1
10.1088/1757-899X/99/1/012027
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84960844856&doi=10.1088%2f1757-899X%2f99%2f1%2f012027&partnerID=40&md5=443d355cee5ad37cabb3020bf74eafe2
Intra-body communication (IBC) is a communication system that uses human body as a signal transmission medium. From previous research, two coupling methods of IBC were concluded which are capacitive coupling and galvanic coupling. This paper investigates the effect of human movement on IBC using the galvanic coupling method. Because the human movement is control by the limb joint, the knee flexion angle during gait cycle was used to examine the influence of human movement on galvanic coupling IBC. The gait cycle is a cycle of people walking that start from one foot touch the ground till that foot touch the ground again. Frequency range from 300 kHz to 200MHz was swept in order to investigate the signal transmission loss and the result was focused on operating frequency 70MHz to 90MHz. Results show that the transmission loss varies when the knee flexion angle increased. The highest loss of signal at frequency range between 70MHz to 90 MHz was 69dB when the knee flexion angle is 50° and the minimum loss was 51dB during the flexion angle is 5°. © Published under licence by IOP Publishing Ltd.
Institute of Physics Publishing
17578981
English
Conference paper
All Open Access; Gold Open Access
author Ibrahim I.W.; Razak A.H.A.; Ahmad A.; Salleh M.K.M.
spellingShingle Ibrahim I.W.; Razak A.H.A.; Ahmad A.; Salleh M.K.M.
Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
author_facet Ibrahim I.W.; Razak A.H.A.; Ahmad A.; Salleh M.K.M.
author_sort Ibrahim I.W.; Razak A.H.A.; Ahmad A.; Salleh M.K.M.
title Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
title_short Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
title_full Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
title_fullStr Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
title_full_unstemmed Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
title_sort Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
publishDate 2015
container_title IOP Conference Series: Materials Science and Engineering
container_volume 99
container_issue 1
doi_str_mv 10.1088/1757-899X/99/1/012027
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84960844856&doi=10.1088%2f1757-899X%2f99%2f1%2f012027&partnerID=40&md5=443d355cee5ad37cabb3020bf74eafe2
description Intra-body communication (IBC) is a communication system that uses human body as a signal transmission medium. From previous research, two coupling methods of IBC were concluded which are capacitive coupling and galvanic coupling. This paper investigates the effect of human movement on IBC using the galvanic coupling method. Because the human movement is control by the limb joint, the knee flexion angle during gait cycle was used to examine the influence of human movement on galvanic coupling IBC. The gait cycle is a cycle of people walking that start from one foot touch the ground till that foot touch the ground again. Frequency range from 300 kHz to 200MHz was swept in order to investigate the signal transmission loss and the result was focused on operating frequency 70MHz to 90MHz. Results show that the transmission loss varies when the knee flexion angle increased. The highest loss of signal at frequency range between 70MHz to 90 MHz was 69dB when the knee flexion angle is 50° and the minimum loss was 51dB during the flexion angle is 5°. © Published under licence by IOP Publishing Ltd.
publisher Institute of Physics Publishing
issn 17578981
language English
format Conference paper
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677910515122176