PID position control of 7-DOF three-fingered robotic hand for grasping task

This paper presents the tuning of PID control parameters for position feedback control of motor and the position reference design for grasping task by a 7-degree of freedom (DOF) three-fingered robotic hand. The system of the robotic hand consists of DC-motors, magnetic encoder and a motion controll...

Full description

Bibliographic Details
Published in:Proceedings - 4th IEEE International Conference on Control System, Computing and Engineering, ICCSCE 2014
Main Author: Shauri R.L.A.; Salleh N.M.; Hadi A.K.A.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2014
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84946692891&doi=10.1109%2fICCSCE.2014.7072691&partnerID=40&md5=20b8dba045492591161cbbe792453042
id 2-s2.0-84946692891
spelling 2-s2.0-84946692891
Shauri R.L.A.; Salleh N.M.; Hadi A.K.A.
PID position control of 7-DOF three-fingered robotic hand for grasping task
2014
Proceedings - 4th IEEE International Conference on Control System, Computing and Engineering, ICCSCE 2014


10.1109/ICCSCE.2014.7072691
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84946692891&doi=10.1109%2fICCSCE.2014.7072691&partnerID=40&md5=20b8dba045492591161cbbe792453042
This paper presents the tuning of PID control parameters for position feedback control of motor and the position reference design for grasping task by a 7-degree of freedom (DOF) three-fingered robotic hand. The system of the robotic hand consists of DC-motors, magnetic encoder and a motion controller unit. The robotic hand has three fingers where each finger has two joints and two links made of perspective plastic material. The PID tuning is implemented to all six motors that are used to move all joints of the three fingers. Trial and error method is used for tuning the parameter of PID control to improve the transient response performance of the motors. For the position reference design, a set of position data is identified to produce the grasping trajectory for all finger joints. The trajectory for the robotic hand performs two types of finger configuration for grasping two different shapes of household solid objects. Both works were implemented via programming in Motion Manager Application. It has been observed that the robot hand has performed well with the tuned PID parameters by reducing the overshoot, rise time (Tr), peak time (Tp), settling time (Ts) and steady state error (ess). Besides, the robot hand has also succeeded the grasping task with the proposed position reference trajectory. © 2014 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Shauri R.L.A.; Salleh N.M.; Hadi A.K.A.
spellingShingle Shauri R.L.A.; Salleh N.M.; Hadi A.K.A.
PID position control of 7-DOF three-fingered robotic hand for grasping task
author_facet Shauri R.L.A.; Salleh N.M.; Hadi A.K.A.
author_sort Shauri R.L.A.; Salleh N.M.; Hadi A.K.A.
title PID position control of 7-DOF three-fingered robotic hand for grasping task
title_short PID position control of 7-DOF three-fingered robotic hand for grasping task
title_full PID position control of 7-DOF three-fingered robotic hand for grasping task
title_fullStr PID position control of 7-DOF three-fingered robotic hand for grasping task
title_full_unstemmed PID position control of 7-DOF three-fingered robotic hand for grasping task
title_sort PID position control of 7-DOF three-fingered robotic hand for grasping task
publishDate 2014
container_title Proceedings - 4th IEEE International Conference on Control System, Computing and Engineering, ICCSCE 2014
container_volume
container_issue
doi_str_mv 10.1109/ICCSCE.2014.7072691
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84946692891&doi=10.1109%2fICCSCE.2014.7072691&partnerID=40&md5=20b8dba045492591161cbbe792453042
description This paper presents the tuning of PID control parameters for position feedback control of motor and the position reference design for grasping task by a 7-degree of freedom (DOF) three-fingered robotic hand. The system of the robotic hand consists of DC-motors, magnetic encoder and a motion controller unit. The robotic hand has three fingers where each finger has two joints and two links made of perspective plastic material. The PID tuning is implemented to all six motors that are used to move all joints of the three fingers. Trial and error method is used for tuning the parameter of PID control to improve the transient response performance of the motors. For the position reference design, a set of position data is identified to produce the grasping trajectory for all finger joints. The trajectory for the robotic hand performs two types of finger configuration for grasping two different shapes of household solid objects. Both works were implemented via programming in Motion Manager Application. It has been observed that the robot hand has performed well with the tuned PID parameters by reducing the overshoot, rise time (Tr), peak time (Tp), settling time (Ts) and steady state error (ess). Besides, the robot hand has also succeeded the grasping task with the proposed position reference trajectory. © 2014 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677609442738176