Converting constant amplitude loading of prestressed concrete sleeper (PCS) from variable amplitude

Prestressed Concrete Sleepers are structures that support railway system and absorb variable loading from the train that pass along the rail. In this study, variable amplitude loading from PCS taken from site measurement was converted into constant amplitude loading. Therefore the number of cycles a...

Full description

Bibliographic Details
Published in:Jurnal Teknologi
Main Author: Sharul Nizam I.; Afidah A.B.; Siti Hawa H.; Mohd Ikmal Fazlan R.
Format: Article
Language:English
Published: Penerbit UTM Press 2015
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84944604441&doi=10.11113%2fjt.v76.5910&partnerID=40&md5=c770c0a9f5ddb91b2bfe8a49114f53f1
id 2-s2.0-84944604441
spelling 2-s2.0-84944604441
Sharul Nizam I.; Afidah A.B.; Siti Hawa H.; Mohd Ikmal Fazlan R.
Converting constant amplitude loading of prestressed concrete sleeper (PCS) from variable amplitude
2015
Jurnal Teknologi
76
11
10.11113/jt.v76.5910
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84944604441&doi=10.11113%2fjt.v76.5910&partnerID=40&md5=c770c0a9f5ddb91b2bfe8a49114f53f1
Prestressed Concrete Sleepers are structures that support railway system and absorb variable loading from the train that pass along the rail. In this study, variable amplitude loading from PCS taken from site measurement was converted into constant amplitude loading. Therefore the number of cycles and frequency are also important to be determined. There are various method for counting the number of cycles and the best adoptive method was Rainflow Cycle Counting. Once the number of cycles is obtained as well as the constant amplitude stress in a series of stress block, the prediction of fatigue life of PCS can be analyzed by further research in the laboratory work. However the limitation of this study is only to obtain the constant amplitude loading of PCS and also counting the number of cycles in various series of stress blocks. © 2015 Penerbit UTM Press. All rights reserved.
Penerbit UTM Press
1279696
English
Article
All Open Access; Bronze Open Access
author Sharul Nizam I.; Afidah A.B.; Siti Hawa H.; Mohd Ikmal Fazlan R.
spellingShingle Sharul Nizam I.; Afidah A.B.; Siti Hawa H.; Mohd Ikmal Fazlan R.
Converting constant amplitude loading of prestressed concrete sleeper (PCS) from variable amplitude
author_facet Sharul Nizam I.; Afidah A.B.; Siti Hawa H.; Mohd Ikmal Fazlan R.
author_sort Sharul Nizam I.; Afidah A.B.; Siti Hawa H.; Mohd Ikmal Fazlan R.
title Converting constant amplitude loading of prestressed concrete sleeper (PCS) from variable amplitude
title_short Converting constant amplitude loading of prestressed concrete sleeper (PCS) from variable amplitude
title_full Converting constant amplitude loading of prestressed concrete sleeper (PCS) from variable amplitude
title_fullStr Converting constant amplitude loading of prestressed concrete sleeper (PCS) from variable amplitude
title_full_unstemmed Converting constant amplitude loading of prestressed concrete sleeper (PCS) from variable amplitude
title_sort Converting constant amplitude loading of prestressed concrete sleeper (PCS) from variable amplitude
publishDate 2015
container_title Jurnal Teknologi
container_volume 76
container_issue 11
doi_str_mv 10.11113/jt.v76.5910
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84944604441&doi=10.11113%2fjt.v76.5910&partnerID=40&md5=c770c0a9f5ddb91b2bfe8a49114f53f1
description Prestressed Concrete Sleepers are structures that support railway system and absorb variable loading from the train that pass along the rail. In this study, variable amplitude loading from PCS taken from site measurement was converted into constant amplitude loading. Therefore the number of cycles and frequency are also important to be determined. There are various method for counting the number of cycles and the best adoptive method was Rainflow Cycle Counting. Once the number of cycles is obtained as well as the constant amplitude stress in a series of stress block, the prediction of fatigue life of PCS can be analyzed by further research in the laboratory work. However the limitation of this study is only to obtain the constant amplitude loading of PCS and also counting the number of cycles in various series of stress blocks. © 2015 Penerbit UTM Press. All rights reserved.
publisher Penerbit UTM Press
issn 1279696
language English
format Article
accesstype All Open Access; Bronze Open Access
record_format scopus
collection Scopus
_version_ 1809677687781851136