The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography

The aim of this project was to study the effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography. The specific objectives of this study were to verify the relationship between density, contrast and noise of lateral thoraco lumbar radiography using various t...

Full description

Bibliographic Details
Published in:Journal of Physics: Conference Series
Main Author: Daud N.A.A.; Ali M.H.; Nazri N.A.A.; Hamzah N.J.; Awang N.A.
Format: Conference paper
Language:English
Published: Institute of Physics Publishing 2014
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84910068523&doi=10.1088%2f1742-6596%2f546%2f1%2f012002&partnerID=40&md5=4d4cc1d4a66909e61daeb43be58671a3
id 2-s2.0-84910068523
spelling 2-s2.0-84910068523
Daud N.A.A.; Ali M.H.; Nazri N.A.A.; Hamzah N.J.; Awang N.A.
The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography
2014
Journal of Physics: Conference Series
546
1
10.1088/1742-6596/546/1/012002
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84910068523&doi=10.1088%2f1742-6596%2f546%2f1%2f012002&partnerID=40&md5=4d4cc1d4a66909e61daeb43be58671a3
The aim of this project was to study the effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography. The specific objectives of this study were to verify the relationship between density, contrast and noise of lateral thoraco lumbar radiography using various thickness of compensating filter and to determine the appropriate filter thickness with the thoraco lumbar density. The study was performed by an X- ray unit exposed to the body phantom where different thicknesses of aluminium were used as compensating filter. The radiographs were processed by CR reader and being imported to KPACS software to analyze the pixel depth value, contrast and noise. Result shows different thickness of aluminium compensating filter improved the image quality of lateral projection thoraco lumbar radiography. The compensating filter of 8.2 mm was considered as the optimal filter to compensate the thoraco lumbar junction (T12-L1), 1 mm to compensate lumbar region and 5.9 mm to compensate thorax region. The addition of aluminium compensating filter is advantageous in terms of efficiency which saving radiograph film, workload of the radiographer and radiation dose to patient. © Published under licence by IOP Publishing Ltd.
Institute of Physics Publishing
17426588
English
Conference paper
All Open Access; Gold Open Access
author Daud N.A.A.; Ali M.H.; Nazri N.A.A.; Hamzah N.J.; Awang N.A.
spellingShingle Daud N.A.A.; Ali M.H.; Nazri N.A.A.; Hamzah N.J.; Awang N.A.
The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography
author_facet Daud N.A.A.; Ali M.H.; Nazri N.A.A.; Hamzah N.J.; Awang N.A.
author_sort Daud N.A.A.; Ali M.H.; Nazri N.A.A.; Hamzah N.J.; Awang N.A.
title The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography
title_short The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography
title_full The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography
title_fullStr The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography
title_full_unstemmed The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography
title_sort The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography
publishDate 2014
container_title Journal of Physics: Conference Series
container_volume 546
container_issue 1
doi_str_mv 10.1088/1742-6596/546/1/012002
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84910068523&doi=10.1088%2f1742-6596%2f546%2f1%2f012002&partnerID=40&md5=4d4cc1d4a66909e61daeb43be58671a3
description The aim of this project was to study the effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography. The specific objectives of this study were to verify the relationship between density, contrast and noise of lateral thoraco lumbar radiography using various thickness of compensating filter and to determine the appropriate filter thickness with the thoraco lumbar density. The study was performed by an X- ray unit exposed to the body phantom where different thicknesses of aluminium were used as compensating filter. The radiographs were processed by CR reader and being imported to KPACS software to analyze the pixel depth value, contrast and noise. Result shows different thickness of aluminium compensating filter improved the image quality of lateral projection thoraco lumbar radiography. The compensating filter of 8.2 mm was considered as the optimal filter to compensate the thoraco lumbar junction (T12-L1), 1 mm to compensate lumbar region and 5.9 mm to compensate thorax region. The addition of aluminium compensating filter is advantageous in terms of efficiency which saving radiograph film, workload of the radiographer and radiation dose to patient. © Published under licence by IOP Publishing Ltd.
publisher Institute of Physics Publishing
issn 17426588
language English
format Conference paper
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809678488871895040