Two-phase electrodriven membrane extraction combined with liquid chromatography for the determination of tricyclic antidepressants in aqueous matrices

A two-phase low-voltage electrodriven membrane extraction (EME) method combined with high performance liquid chromatography (HPLC) was developed for the determination of tricyclic antidepressants (TCAs) in aqueous matrices. Three TCAs, namely imipramine (IMI), amitriptyline (AMI) and chlorpromazine...

Full description

Bibliographic Details
Published in:Analytical Methods
Main Author: Sanagi M.M.; Mohamad Hanapi N.S.; Ismail A.K.; Wan Ibrahim W.A.; Saim N.; Yahaya N.
Format: Article
Language:English
Published: Royal Society of Chemistry 2014
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84908013387&doi=10.1039%2fc4ay01700e&partnerID=40&md5=5cdfd8dc3ce37ae5c3302f92d8bec178
id 2-s2.0-84908013387
spelling 2-s2.0-84908013387
Sanagi M.M.; Mohamad Hanapi N.S.; Ismail A.K.; Wan Ibrahim W.A.; Saim N.; Yahaya N.
Two-phase electrodriven membrane extraction combined with liquid chromatography for the determination of tricyclic antidepressants in aqueous matrices
2014
Analytical Methods
6
21
10.1039/c4ay01700e
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84908013387&doi=10.1039%2fc4ay01700e&partnerID=40&md5=5cdfd8dc3ce37ae5c3302f92d8bec178
A two-phase low-voltage electrodriven membrane extraction (EME) method combined with high performance liquid chromatography (HPLC) was developed for the determination of tricyclic antidepressants (TCAs) in aqueous matrices. Three TCAs, namely imipramine (IMI), amitriptyline (AMI) and chlorpromazine (CHLO) were used as target analytes. The drugs were extracted from aqueous sample solutions through a porous polypropylene membrane filter impregnated with 2-nitrophenyl octyl ether (NPOE) that served as a supported liquid membrane (SLM), and into an acceptor phase with a potential difference of 10 V applied over the SLM. EME parameters such as the type of organic solvent, the pH of sample solution, the extraction voltage, extraction time and stirring rate were evaluated and optimized. Optimal extractions were accomplished using NPOE as the organic solvent, a sample solution of pH 6, an extraction time of 10 min, and 10 V as the driving force with the whole assembly agitated at 1200 rpm. Under the optimized extraction conditions, the method demonstrated good linearity with coefficients of determination, r2 ≥ 0.9987 in the concentration range of 0.5-1000 g L-1 for water, and 1.0-1000 g L-1 for urine and good limits of detection in the range of 0.05-0.08 g L-1 and 0.1-0.3 g L-1 in water and urine samples, respectively. The method showed high enrichment factors in the range of 91-128 and high relative recoveries in the range of 98.4-103.1% and 86.7-107.4%, for water and urine samples, respectively with RSDs of <9.0% (n = 3). This method was successfully applied to the determination of the drugs in water and human urine samples. The proposed method offered good features such as simplicity, easy handling, fast extraction time, low voltage and minimum organic solvent consumption which meet the green chemistry concept. This journal is © the Partner Organisations 2014.
Royal Society of Chemistry
17599660
English
Article

author Sanagi M.M.; Mohamad Hanapi N.S.; Ismail A.K.; Wan Ibrahim W.A.; Saim N.; Yahaya N.
spellingShingle Sanagi M.M.; Mohamad Hanapi N.S.; Ismail A.K.; Wan Ibrahim W.A.; Saim N.; Yahaya N.
Two-phase electrodriven membrane extraction combined with liquid chromatography for the determination of tricyclic antidepressants in aqueous matrices
author_facet Sanagi M.M.; Mohamad Hanapi N.S.; Ismail A.K.; Wan Ibrahim W.A.; Saim N.; Yahaya N.
author_sort Sanagi M.M.; Mohamad Hanapi N.S.; Ismail A.K.; Wan Ibrahim W.A.; Saim N.; Yahaya N.
title Two-phase electrodriven membrane extraction combined with liquid chromatography for the determination of tricyclic antidepressants in aqueous matrices
title_short Two-phase electrodriven membrane extraction combined with liquid chromatography for the determination of tricyclic antidepressants in aqueous matrices
title_full Two-phase electrodriven membrane extraction combined with liquid chromatography for the determination of tricyclic antidepressants in aqueous matrices
title_fullStr Two-phase electrodriven membrane extraction combined with liquid chromatography for the determination of tricyclic antidepressants in aqueous matrices
title_full_unstemmed Two-phase electrodriven membrane extraction combined with liquid chromatography for the determination of tricyclic antidepressants in aqueous matrices
title_sort Two-phase electrodriven membrane extraction combined with liquid chromatography for the determination of tricyclic antidepressants in aqueous matrices
publishDate 2014
container_title Analytical Methods
container_volume 6
container_issue 21
doi_str_mv 10.1039/c4ay01700e
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84908013387&doi=10.1039%2fc4ay01700e&partnerID=40&md5=5cdfd8dc3ce37ae5c3302f92d8bec178
description A two-phase low-voltage electrodriven membrane extraction (EME) method combined with high performance liquid chromatography (HPLC) was developed for the determination of tricyclic antidepressants (TCAs) in aqueous matrices. Three TCAs, namely imipramine (IMI), amitriptyline (AMI) and chlorpromazine (CHLO) were used as target analytes. The drugs were extracted from aqueous sample solutions through a porous polypropylene membrane filter impregnated with 2-nitrophenyl octyl ether (NPOE) that served as a supported liquid membrane (SLM), and into an acceptor phase with a potential difference of 10 V applied over the SLM. EME parameters such as the type of organic solvent, the pH of sample solution, the extraction voltage, extraction time and stirring rate were evaluated and optimized. Optimal extractions were accomplished using NPOE as the organic solvent, a sample solution of pH 6, an extraction time of 10 min, and 10 V as the driving force with the whole assembly agitated at 1200 rpm. Under the optimized extraction conditions, the method demonstrated good linearity with coefficients of determination, r2 ≥ 0.9987 in the concentration range of 0.5-1000 g L-1 for water, and 1.0-1000 g L-1 for urine and good limits of detection in the range of 0.05-0.08 g L-1 and 0.1-0.3 g L-1 in water and urine samples, respectively. The method showed high enrichment factors in the range of 91-128 and high relative recoveries in the range of 98.4-103.1% and 86.7-107.4%, for water and urine samples, respectively with RSDs of <9.0% (n = 3). This method was successfully applied to the determination of the drugs in water and human urine samples. The proposed method offered good features such as simplicity, easy handling, fast extraction time, low voltage and minimum organic solvent consumption which meet the green chemistry concept. This journal is © the Partner Organisations 2014.
publisher Royal Society of Chemistry
issn 17599660
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1809677788350775296