Assessment of environmental noise and air quality in critical areas at uiTM engineering complex

Excessive environmental noise and poor air quality can be adverse to human health, living comfort and the environment itself. Measurement of sound pressure levels and air quality in critical areas including libraries, campus areas, public parks and hospitals thus becomes necessary to monitor and mit...

Full description

Bibliographic Details
Published in:Applied Mechanics and Materials
Main Author: David N.V.; Ismail K.
Format: Conference paper
Language:English
Published: Trans Tech Publications Ltd 2014
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84891516579&doi=10.4028%2fwww.scientific.net%2fAMM.471.125&partnerID=40&md5=62df8ee36058bd47d8c21466f03e7642
id 2-s2.0-84891516579
spelling 2-s2.0-84891516579
David N.V.; Ismail K.
Assessment of environmental noise and air quality in critical areas at uiTM engineering complex
2014
Applied Mechanics and Materials
471

10.4028/www.scientific.net/AMM.471.125
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84891516579&doi=10.4028%2fwww.scientific.net%2fAMM.471.125&partnerID=40&md5=62df8ee36058bd47d8c21466f03e7642
Excessive environmental noise and poor air quality can be adverse to human health, living comfort and the environment itself. Measurement of sound pressure levels and air quality in critical areas including libraries, campus areas, public parks and hospitals thus becomes necessary to monitor and mitigate existing noise levels. In a university environment, student activities will be less disrupted if the locations of the activities are sufficiently away from noise sources. The present study is intended to measure sound levels and air quality around the Engineering Complex, Universiti Teknologi Mara, Shah Alam. The measured data is compared with to acceptable sound pressure levels and air quality index specified by the Department of Environment (DOE), Malaysia. Sound pressure levels are measured using the Castle Sound Level Meter Type 6224 and air quality measurement was done by using the BW Gas Alert MicroClip XT device. Both measurements were conducted at five selected stations around the Engineering Complex for three times each weekday for five weeks. Results obtained indicated that sound levels at some locations and time zones are above the thresholds recommended by the DOE. The air quality is acceptable in most locations except the vicinity of a bus stop. With the growing number of students in the university and other factors like construction and redevelopment of existing roads, a continuously increasing noise situations and air pollution proportional to the traffic flow is inevitable. © (2014) Trans Tech Publications, Switzerland.
Trans Tech Publications Ltd
16609336
English
Conference paper

author David N.V.; Ismail K.
spellingShingle David N.V.; Ismail K.
Assessment of environmental noise and air quality in critical areas at uiTM engineering complex
author_facet David N.V.; Ismail K.
author_sort David N.V.; Ismail K.
title Assessment of environmental noise and air quality in critical areas at uiTM engineering complex
title_short Assessment of environmental noise and air quality in critical areas at uiTM engineering complex
title_full Assessment of environmental noise and air quality in critical areas at uiTM engineering complex
title_fullStr Assessment of environmental noise and air quality in critical areas at uiTM engineering complex
title_full_unstemmed Assessment of environmental noise and air quality in critical areas at uiTM engineering complex
title_sort Assessment of environmental noise and air quality in critical areas at uiTM engineering complex
publishDate 2014
container_title Applied Mechanics and Materials
container_volume 471
container_issue
doi_str_mv 10.4028/www.scientific.net/AMM.471.125
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84891516579&doi=10.4028%2fwww.scientific.net%2fAMM.471.125&partnerID=40&md5=62df8ee36058bd47d8c21466f03e7642
description Excessive environmental noise and poor air quality can be adverse to human health, living comfort and the environment itself. Measurement of sound pressure levels and air quality in critical areas including libraries, campus areas, public parks and hospitals thus becomes necessary to monitor and mitigate existing noise levels. In a university environment, student activities will be less disrupted if the locations of the activities are sufficiently away from noise sources. The present study is intended to measure sound levels and air quality around the Engineering Complex, Universiti Teknologi Mara, Shah Alam. The measured data is compared with to acceptable sound pressure levels and air quality index specified by the Department of Environment (DOE), Malaysia. Sound pressure levels are measured using the Castle Sound Level Meter Type 6224 and air quality measurement was done by using the BW Gas Alert MicroClip XT device. Both measurements were conducted at five selected stations around the Engineering Complex for three times each weekday for five weeks. Results obtained indicated that sound levels at some locations and time zones are above the thresholds recommended by the DOE. The air quality is acceptable in most locations except the vicinity of a bus stop. With the growing number of students in the university and other factors like construction and redevelopment of existing roads, a continuously increasing noise situations and air pollution proportional to the traffic flow is inevitable. © (2014) Trans Tech Publications, Switzerland.
publisher Trans Tech Publications Ltd
issn 16609336
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1823296165235392512