Performance analysis of journal bearings using ultrasonic reflection
One method that shows potential for non-invasive oil film measurement is the use of ultrasonic reflection. In the current work, ultrasonic transducer is coupled to the outside of a bearing and a wave transmitted through the bearing shell. The wave is partially reflected when it strikes an oil film....
Published in: | Tribology International |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
2013
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84875739362&doi=10.1016%2fj.triboint.2013.02.012&partnerID=40&md5=909325a6e043031d1561ee2b0c3db827 |
id |
2-s2.0-84875739362 |
---|---|
spelling |
2-s2.0-84875739362 Kasolang S.; Ahmed D.I.; Dwyer-Joyce R.S.; Yousif B.F. Performance analysis of journal bearings using ultrasonic reflection 2013 Tribology International 64 10.1016/j.triboint.2013.02.012 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84875739362&doi=10.1016%2fj.triboint.2013.02.012&partnerID=40&md5=909325a6e043031d1561ee2b0c3db827 One method that shows potential for non-invasive oil film measurement is the use of ultrasonic reflection. In the current work, ultrasonic transducer is coupled to the outside of a bearing and a wave transmitted through the bearing shell. The wave is partially reflected when it strikes an oil film. Experiments were conducted to study ultrasonic reflection coefficient technique in plain journal bearing. Measurements of multiple reflection coefficients were recorded and used to map the viscosity profiles, oil-film thickness and bearing cavitation. In addition, an alternative method using the reflection coefficient phase from film thickness measurement was used for verification. The results revealed that the evaluation of phase method is slightly lower compared to that of the amplitude method. The film thickness profile obtained in the converging region agreed well with classical hydrodynamic predictions. © 2013 Elsevier Ltd. 0301679X English Article |
author |
Kasolang S.; Ahmed D.I.; Dwyer-Joyce R.S.; Yousif B.F. |
spellingShingle |
Kasolang S.; Ahmed D.I.; Dwyer-Joyce R.S.; Yousif B.F. Performance analysis of journal bearings using ultrasonic reflection |
author_facet |
Kasolang S.; Ahmed D.I.; Dwyer-Joyce R.S.; Yousif B.F. |
author_sort |
Kasolang S.; Ahmed D.I.; Dwyer-Joyce R.S.; Yousif B.F. |
title |
Performance analysis of journal bearings using ultrasonic reflection |
title_short |
Performance analysis of journal bearings using ultrasonic reflection |
title_full |
Performance analysis of journal bearings using ultrasonic reflection |
title_fullStr |
Performance analysis of journal bearings using ultrasonic reflection |
title_full_unstemmed |
Performance analysis of journal bearings using ultrasonic reflection |
title_sort |
Performance analysis of journal bearings using ultrasonic reflection |
publishDate |
2013 |
container_title |
Tribology International |
container_volume |
64 |
container_issue |
|
doi_str_mv |
10.1016/j.triboint.2013.02.012 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84875739362&doi=10.1016%2fj.triboint.2013.02.012&partnerID=40&md5=909325a6e043031d1561ee2b0c3db827 |
description |
One method that shows potential for non-invasive oil film measurement is the use of ultrasonic reflection. In the current work, ultrasonic transducer is coupled to the outside of a bearing and a wave transmitted through the bearing shell. The wave is partially reflected when it strikes an oil film. Experiments were conducted to study ultrasonic reflection coefficient technique in plain journal bearing. Measurements of multiple reflection coefficients were recorded and used to map the viscosity profiles, oil-film thickness and bearing cavitation. In addition, an alternative method using the reflection coefficient phase from film thickness measurement was used for verification. The results revealed that the evaluation of phase method is slightly lower compared to that of the amplitude method. The film thickness profile obtained in the converging region agreed well with classical hydrodynamic predictions. © 2013 Elsevier Ltd. |
publisher |
|
issn |
0301679X |
language |
English |
format |
Article |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1818940564229324800 |