An observation of noise intervention into acoustic emission signal on concrete structure
This paper is presented the observation of noise intervention into acoustic emission (AE) signal on reinforced concrete beam based on data recorded in the AEWin software at different pre-set thresholds manually. Two kinds of sources were selected; namely in-plane source and out-plane source. The cor...
Published in: | Proceedings - 2011 IEEE 7th International Colloquium on Signal Processing and Its Applications, CSPA 2011 |
---|---|
Main Author: | |
Format: | Conference paper |
Language: | English |
Published: |
2011
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-79957442874&doi=10.1109%2fCSPA.2011.5759832&partnerID=40&md5=8f9f5a35cdc6a2dcfd74f0d3de8e64ed |
id |
2-s2.0-79957442874 |
---|---|
spelling |
2-s2.0-79957442874 Md Nor N.; Muhamad Bunnori N.; Ibrahim A.; Shahidan S.; Saliah S.N.M. An observation of noise intervention into acoustic emission signal on concrete structure 2011 Proceedings - 2011 IEEE 7th International Colloquium on Signal Processing and Its Applications, CSPA 2011 10.1109/CSPA.2011.5759832 https://www.scopus.com/inward/record.uri?eid=2-s2.0-79957442874&doi=10.1109%2fCSPA.2011.5759832&partnerID=40&md5=8f9f5a35cdc6a2dcfd74f0d3de8e64ed This paper is presented the observation of noise intervention into acoustic emission (AE) signal on reinforced concrete beam based on data recorded in the AEWin software at different pre-set thresholds manually. Two kinds of sources were selected; namely in-plane source and out-plane source. The correlation between threshold levels and number of hits has been observed. It can be concluded that for both AE sources in-plane and out of plane at the lower threshold level, huge hits were produced which including unwanted hits as well as noise. At high threshold level only required data / hits were recorded by AE signals, where the data presented owing to sudden release of stress from pencil lead fracture at selected source location. Thus, it produced lower correlation between threshold levels and a total number of hits recorded as the coefficient of determination for both sources is around 0.8 only and the graph produced is not linear. © 2011 IEEE. English Conference paper |
author |
Md Nor N.; Muhamad Bunnori N.; Ibrahim A.; Shahidan S.; Saliah S.N.M. |
spellingShingle |
Md Nor N.; Muhamad Bunnori N.; Ibrahim A.; Shahidan S.; Saliah S.N.M. An observation of noise intervention into acoustic emission signal on concrete structure |
author_facet |
Md Nor N.; Muhamad Bunnori N.; Ibrahim A.; Shahidan S.; Saliah S.N.M. |
author_sort |
Md Nor N.; Muhamad Bunnori N.; Ibrahim A.; Shahidan S.; Saliah S.N.M. |
title |
An observation of noise intervention into acoustic emission signal on concrete structure |
title_short |
An observation of noise intervention into acoustic emission signal on concrete structure |
title_full |
An observation of noise intervention into acoustic emission signal on concrete structure |
title_fullStr |
An observation of noise intervention into acoustic emission signal on concrete structure |
title_full_unstemmed |
An observation of noise intervention into acoustic emission signal on concrete structure |
title_sort |
An observation of noise intervention into acoustic emission signal on concrete structure |
publishDate |
2011 |
container_title |
Proceedings - 2011 IEEE 7th International Colloquium on Signal Processing and Its Applications, CSPA 2011 |
container_volume |
|
container_issue |
|
doi_str_mv |
10.1109/CSPA.2011.5759832 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-79957442874&doi=10.1109%2fCSPA.2011.5759832&partnerID=40&md5=8f9f5a35cdc6a2dcfd74f0d3de8e64ed |
description |
This paper is presented the observation of noise intervention into acoustic emission (AE) signal on reinforced concrete beam based on data recorded in the AEWin software at different pre-set thresholds manually. Two kinds of sources were selected; namely in-plane source and out-plane source. The correlation between threshold levels and number of hits has been observed. It can be concluded that for both AE sources in-plane and out of plane at the lower threshold level, huge hits were produced which including unwanted hits as well as noise. At high threshold level only required data / hits were recorded by AE signals, where the data presented owing to sudden release of stress from pencil lead fracture at selected source location. Thus, it produced lower correlation between threshold levels and a total number of hits recorded as the coefficient of determination for both sources is around 0.8 only and the graph produced is not linear. © 2011 IEEE. |
publisher |
|
issn |
|
language |
English |
format |
Conference paper |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1809677613095976960 |