Harmonic and neutral to ground voltage reduction using isolation transformer

Service reliability and quality of power have become a growing concern especially with the increasing sensitivity of electronic equipment which generates harmonic current and voltage in distribution system posing new problems for electrical engineers. This power quality problem is of prime concern d...

Full description

Bibliographic Details
Published in:PECon2010 - 2010 IEEE International Conference on Power and Energy
Main Author: Shafie M.A.; Singh H.; Rahman M.Q.A.
Format: Conference paper
Language:English
Published: 2010
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-79951803067&doi=10.1109%2fPECON.2010.5697645&partnerID=40&md5=8f42926d9a1bed5e8908ad9082e894e0
id 2-s2.0-79951803067
spelling 2-s2.0-79951803067
Shafie M.A.; Singh H.; Rahman M.Q.A.
Harmonic and neutral to ground voltage reduction using isolation transformer
2010
PECon2010 - 2010 IEEE International Conference on Power and Energy


10.1109/PECON.2010.5697645
https://www.scopus.com/inward/record.uri?eid=2-s2.0-79951803067&doi=10.1109%2fPECON.2010.5697645&partnerID=40&md5=8f42926d9a1bed5e8908ad9082e894e0
Service reliability and quality of power have become a growing concern especially with the increasing sensitivity of electronic equipment which generates harmonic current and voltage in distribution system posing new problems for electrical engineers. This power quality problem is of prime concern due to non-linear loads showing distorted current and voltage waveforms. An unexpected side effect of distributed non-linear loads is an increase in neutral-ground voltages on distribution systems. In this paper, a study was done to determine the power quality for the several computer labs at UiTM Penang. The reduction of harmonic voltage and neutral to ground voltage using isolation transformer was analyzed. Isolation transformer is used to improve the harmonics as well as neutral to ground voltage. The findings identified the harmonic content is in full compliance with the IEEE standards. ©2010 IEEE.


English
Conference paper

author Shafie M.A.; Singh H.; Rahman M.Q.A.
spellingShingle Shafie M.A.; Singh H.; Rahman M.Q.A.
Harmonic and neutral to ground voltage reduction using isolation transformer
author_facet Shafie M.A.; Singh H.; Rahman M.Q.A.
author_sort Shafie M.A.; Singh H.; Rahman M.Q.A.
title Harmonic and neutral to ground voltage reduction using isolation transformer
title_short Harmonic and neutral to ground voltage reduction using isolation transformer
title_full Harmonic and neutral to ground voltage reduction using isolation transformer
title_fullStr Harmonic and neutral to ground voltage reduction using isolation transformer
title_full_unstemmed Harmonic and neutral to ground voltage reduction using isolation transformer
title_sort Harmonic and neutral to ground voltage reduction using isolation transformer
publishDate 2010
container_title PECon2010 - 2010 IEEE International Conference on Power and Energy
container_volume
container_issue
doi_str_mv 10.1109/PECON.2010.5697645
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-79951803067&doi=10.1109%2fPECON.2010.5697645&partnerID=40&md5=8f42926d9a1bed5e8908ad9082e894e0
description Service reliability and quality of power have become a growing concern especially with the increasing sensitivity of electronic equipment which generates harmonic current and voltage in distribution system posing new problems for electrical engineers. This power quality problem is of prime concern due to non-linear loads showing distorted current and voltage waveforms. An unexpected side effect of distributed non-linear loads is an increase in neutral-ground voltages on distribution systems. In this paper, a study was done to determine the power quality for the several computer labs at UiTM Penang. The reduction of harmonic voltage and neutral to ground voltage using isolation transformer was analyzed. Isolation transformer is used to improve the harmonics as well as neutral to ground voltage. The findings identified the harmonic content is in full compliance with the IEEE standards. ©2010 IEEE.
publisher
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677914999881728