Monitoring of a 1 kWp solar photovoltaic system

A 1 kWp 'stand alone' PV system consists of 4 module (2 BP SX75U module and 2 BP 275F module), inverter, 2 thermocouple, 3 voltage sensor, 3 current sensor,4 battery and data logger (Data Taker DT80) has been set up. This research involve nine parameters which are irradiance (I a), ambient...

Full description

Bibliographic Details
Published in:AIP Conference Proceedings
Main Author: Malek M.F.; Zainuddin H.; Rejab S.N.M.; Shaari S.N.; Shaari S.; Omar A.M.; Rusop M.
Format: Conference paper
Language:English
Published: 2009
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-70450225783&doi=10.1063%2f1.3160220&partnerID=40&md5=1c64a148009630323d0bfb3d2f345a26
id 2-s2.0-70450225783
spelling 2-s2.0-70450225783
Malek M.F.; Zainuddin H.; Rejab S.N.M.; Shaari S.N.; Shaari S.; Omar A.M.; Rusop M.
Monitoring of a 1 kWp solar photovoltaic system
2009
AIP Conference Proceedings
1136

10.1063/1.3160220
https://www.scopus.com/inward/record.uri?eid=2-s2.0-70450225783&doi=10.1063%2f1.3160220&partnerID=40&md5=1c64a148009630323d0bfb3d2f345a26
A 1 kWp 'stand alone' PV system consists of 4 module (2 BP SX75U module and 2 BP 275F module), inverter, 2 thermocouple, 3 voltage sensor, 3 current sensor,4 battery and data logger (Data Taker DT80) has been set up. This research involve nine parameters which are irradiance (I a), ambient temperature (Tamb), module temperature (T mod), module voltage (Vmod), battery voltage (V bat), load voltage (Vload), module current (I mod), battery current (Ibat) and load current (I load). All parameters were measured using the equipments and sensors that connected directly to data logger (Data Taker DT80) to interpret and show the data on computer using the Delogger sofware. The data then was transferred into the computer and analyzed using the Deview and Microsoft Excel software to determine the performance indices for the stand alone PV system. From the analysis a few performance indices were determined. The range of daily solar irradiation is between 2.20 kWhm-2 to 4.00 kWhm-2, while the range of total global irradiation is between 5.76 kWh to 10.48 kWh. For daily total energy yield, the range is between 0.23 kWh d-1 to 0.28 kWh d-1. The range for clearness index is between 0.49% to 0.89%. The range for final yield is between 0.77 kWh d-1 kWp - 1 to 0.93 kWh d-1 kWp -1 while the range of array efficiency is between 2.53% to 4.65%. Lastly, the range of the performance ratio is between 22.08% to 40.58%. © 2009 American Institute of Physics.

15517616
English
Conference paper

author Malek M.F.; Zainuddin H.; Rejab S.N.M.; Shaari S.N.; Shaari S.; Omar A.M.; Rusop M.
spellingShingle Malek M.F.; Zainuddin H.; Rejab S.N.M.; Shaari S.N.; Shaari S.; Omar A.M.; Rusop M.
Monitoring of a 1 kWp solar photovoltaic system
author_facet Malek M.F.; Zainuddin H.; Rejab S.N.M.; Shaari S.N.; Shaari S.; Omar A.M.; Rusop M.
author_sort Malek M.F.; Zainuddin H.; Rejab S.N.M.; Shaari S.N.; Shaari S.; Omar A.M.; Rusop M.
title Monitoring of a 1 kWp solar photovoltaic system
title_short Monitoring of a 1 kWp solar photovoltaic system
title_full Monitoring of a 1 kWp solar photovoltaic system
title_fullStr Monitoring of a 1 kWp solar photovoltaic system
title_full_unstemmed Monitoring of a 1 kWp solar photovoltaic system
title_sort Monitoring of a 1 kWp solar photovoltaic system
publishDate 2009
container_title AIP Conference Proceedings
container_volume 1136
container_issue
doi_str_mv 10.1063/1.3160220
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-70450225783&doi=10.1063%2f1.3160220&partnerID=40&md5=1c64a148009630323d0bfb3d2f345a26
description A 1 kWp 'stand alone' PV system consists of 4 module (2 BP SX75U module and 2 BP 275F module), inverter, 2 thermocouple, 3 voltage sensor, 3 current sensor,4 battery and data logger (Data Taker DT80) has been set up. This research involve nine parameters which are irradiance (I a), ambient temperature (Tamb), module temperature (T mod), module voltage (Vmod), battery voltage (V bat), load voltage (Vload), module current (I mod), battery current (Ibat) and load current (I load). All parameters were measured using the equipments and sensors that connected directly to data logger (Data Taker DT80) to interpret and show the data on computer using the Delogger sofware. The data then was transferred into the computer and analyzed using the Deview and Microsoft Excel software to determine the performance indices for the stand alone PV system. From the analysis a few performance indices were determined. The range of daily solar irradiation is between 2.20 kWhm-2 to 4.00 kWhm-2, while the range of total global irradiation is between 5.76 kWh to 10.48 kWh. For daily total energy yield, the range is between 0.23 kWh d-1 to 0.28 kWh d-1. The range for clearness index is between 0.49% to 0.89%. The range for final yield is between 0.77 kWh d-1 kWp - 1 to 0.93 kWh d-1 kWp -1 while the range of array efficiency is between 2.53% to 4.65%. Lastly, the range of the performance ratio is between 22.08% to 40.58%. © 2009 American Institute of Physics.
publisher
issn 15517616
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677613853048832